Explore More Products
- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Xindun solar
-
Model Number:
-
XD-Lf solar inverter
-
Input Voltage:
-
12v 24v 48v
-
Output Voltage:
-
110v/120v/220v/230v/240v
-
Output Current:
-
0~30a
-
Output Frequency:
-
50Hz/60Hz
-
Size:
-
500*300*140mm~530*335*150mm
-
Certificate:
-
CE ROHS
-
Warranty:
-
12 months
-
Weight:
-
12kg~26kg
-
Protection:
-
OverLoad/ Over Voltage/ short circuit
-
Output waveform:
-
Pure Sine Wave Output Solar Inverter
-
Application:
-
Home Appliance/office/industrial/ solar inverter system
-
Frequency:
-
Low frequency solar inverter
-
Color:
-
White Color or Customized Inverter
-
Product name:
-
Hybrid Solar Power Inverter Converters
-
Display:
-
LCD display solar inverter
-
Rated power:
-
5kw 2kva 3000w 5kva 3kw
-
Battery type:
-
Lead Acid Battery \ Lithium ion Battery \ Gel Battery
-
OEM:
-
Accept OEM
Quick Details
-
Output Type:
-
Single
-
Type:
-
DC/AC Inverters
-
Inverter Efficiency:
-
85%
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Xindun solar
-
Model Number:
-
XD-Lf solar inverter
-
Input Voltage:
-
12v 24v 48v
-
Output Voltage:
-
110v/120v/220v/230v/240v
-
Output Current:
-
0~30a
-
Output Frequency:
-
50Hz/60Hz
-
Size:
-
500*300*140mm~530*335*150mm
-
Certificate:
-
CE ROHS
-
Warranty:
-
12 months
-
Weight:
-
12kg~26kg
-
Protection:
-
OverLoad/ Over Voltage/ short circuit
-
Output waveform:
-
Pure Sine Wave Output Solar Inverter
-
Application:
-
Home Appliance/office/industrial/ solar inverter system
-
Frequency:
-
Low frequency solar inverter
-
Color:
-
White Color or Customized Inverter
-
Product name:
-
Hybrid Solar Power Inverter Converters
-
Display:
-
LCD display solar inverter
-
Rated power:
-
5kw 2kva 3000w 5kva 3kw
-
Battery type:
-
Lead Acid Battery \ Lithium ion Battery \ Gel Battery
-
OEM:
-
Accept OEM
Feature
1. Pure sine wave, toroidal low loss transformer, customizable mode dual output voltage.
2.Smart LCD show equipment status and parameters.
3.The adjustable mains charging current range is 0~30A.
4.Suffer 3 times peak power, ensure the safe and stable operation of the equipment.
5.Support diesel and gasoline generators, suitable for various power grid.
6.Suitable for industrial and residential used, wall-mounted desigm.
2.Smart LCD show equipment status and parameters.
3.The adjustable mains charging current range is 0~30A.
4.Suffer 3 times peak power, ensure the safe and stable operation of the equipment.
5.Support diesel and gasoline generators, suitable for various power grid.
6.Suitable for industrial and residential used, wall-mounted desigm.
LF Series Model
Highlight
Product Detail
Specification
Specification
|
|
|
|
|
|
|
|
|
|
|||||||||
Model: LF/LF-T
|
|
15212/24/48
|
20212/24/48
|
30224/48
|
40224/48
|
50248
|
60248
|
70248
|
80248
|
|||||||||
Rated Power
|
|
1500W
|
2000W
|
3000W
|
4000W
|
5000W
|
6000W
|
7000W
|
8000W
|
|||||||||
Battery Voltage
|
|
12/24/48VDC
|
|
24/48VDC
|
|
48VDC
|
|
|
|
|||||||||
Size(L*W*Hmm)
|
|
470x300x148
|
|
|
530x335x158
|
|
|
|
684x430x250
|
|||||||||
Packing Size(L*W*Hmm)
|
|
545x385x223
|
|
|
605x420x233
|
|
|
|
705x485x315
|
|||||||||
N.W.(kg)
|
|
13.5
|
18
|
20
|
22
|
24
|
26
|
28
|
47
|
|||||||||
G.W.(kg)
|
|
15
|
19.5
|
21.5
|
24
|
26
|
28
|
30
|
54
|
|||||||||
Installation Method
|
|
Wall-Mounted
|
|
|
|
|
|
|
|
|||||||||
Parameter
|
|
|
|
|
|
|
|
|
|
|||||||||
Input
|
DC Input Voltage Range
|
10.5-15VDC(Single battery voltage)
|
|
|
|
|
|
|
|
|||||||||
|
AC Input Voltage Range
|
80VAC~133VAC(105VAC)/85VAC~138VAC(110VAC)/90VAC~143VAC(115VAC)/95VAC~148VAC(120VAC)
170VAC~275VAC(220VAC)/180VAC~285VAC(230VAC)/190VAC~295VAC(240VAC)(1000W~7000W ) 87VAC~123VAC(105VAC)/92VAC~128VAC(110VAC)/97VAC~133VAC(115VAC)/102VAC~138VAC(120VAC) 185VAC~255VAC(220VAC)/195VAC~265VAC(230VAC)/205VAC~275VAC(240VAC)(8KW~12KW) |
|
|
|
|
|
|
|
|||||||||
|
AC Input Frequency Range
|
45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
|
|
|
|
|
|
|
|
|||||||||
|
Max AC charging current
|
0~30A(Depends on model)
|
|
|
|
|
|
|
|
|||||||||
|
AC charging method
|
Three-stage (constant current, constant voltage, floating charge)
|
|
|
|
|
|
|
|
|||||||||
Output
|
Efficiency(Battery Mode)
|
≥85%
|
|
|
|
|
|
|
|
|||||||||
|
Output Voltage(Battery Mode)
|
AC105V~120V model: 105VAC±2%/110VAC±2%/115VAC±2%/120VAC±2%(can be set)
AC220V~240V model: 220VAC±2%/230VAC±2%/240VAC±2%(can be set) |
|
|
|
|
|
|
|
|||||||||
|
Output Frequency(Battery Mode)
|
50/60Hz±1%(can be set)
|
|
|
|
|
|
|
|
|||||||||
|
Output Wave(Battery Mode)
|
Pure Sine Wave
|
|
|
|
|
|
|
|
|||||||||
|
Efficiency(AC Mode)
|
≥99%
|
|
|
|
|
|
|
|
|||||||||
|
Output Voltage(AC Mode)
|
AC 105V~120V model: 105VAC±10%/110VAC±10%/115VAC±10%/120VAC±10%(can be set)
AC 220V~240V model: 220VAC±10%/230VAC±10%/240VAC10%(can be set) |
|
|
|
|
|
|
|
|||||||||
|
Output Frequency(AC Mode)
|
Follow input
|
|
|
|
|
|
|
|
|||||||||
|
Output waveform distortion
(Battery Mode) |
≤3%(Linear load)
|
|
|
|
|
|
|
|
|||||||||
|
No load loss(Battery Mode)
|
≤1% rated power
|
|
|
|
|
|
|
|
|||||||||
|
No load loss(AC Mode)
|
≤2% rated power( charger does not work in AC mode)
|
|
|
|
|
|
|
|
|||||||||
|
No load loss
(Energy saving Mode) |
≤10W
|
|
|
|
|
|
|
|
|||||||||
Insidc
Solar controller (Optional) |
Charging Mode
|
MPPT
|
|
|
|
|
|
|
|
|||||||||
|
Charging current
|
30A~60A
|
|
|
60A~100A
|
|
|
|
80A~100A
|
|||||||||
|
PV Array Maximum Power
|
12V system: 420W(30A)/560W(40A)/
700W(50A)/840W(60A); 24V system: 840W(30A)/1120W(40A)/ 1400W(50A)/1680W(60A); 48V system : 1680W(30A)/2240W(40A)/ 2800W(50A)/3360W(60A) |
|
|
24V system : 1680W(60A)/2240W(80A)/2800W(100A);
48V system : 3360W(60A)/4480W(80A)/5600W(100A) |
|
|
|
4480W(80A)/5600W(100A)
|
|||||||||
|
Max PV Input Voltage (Voc)
(At the lowest temperature) |
12V/24V system: 120VDC; 48V system: 180VDC
|
|
|
|
|
|
|
|
|||||||||
|
MPPT tracking range
|
12V system: 15V-80V; 24V system: 30V-100V; 48V system : 60V-140V
|
|
|
|
|
|
|
|
|||||||||
|
Standby loss
|
≤3W
|
|
|
|
|
|
|
|
|||||||||
|
Maximum conversion efficiency
|
>95%
|
|
|
|
|
|
|
|
|||||||||
Battery
Type |
Custom battcry
|
Charging and discharging parameters of different types of batteries can be set through the operationpanel by oneself
|
|
|
|
|
|
|
|
|||||||||
Protection
|
Battery lowvoltage alarm / Battery lowvoltage protection / Battery overvoltage alarm / Battery overvoltage protection / Battery
overvoltage recovery voltage / Overload power protection / Inverter output short circuit protection / Temperature protection |
|
|
|
|
|
|
|
|
*lf power is from 1kw~12kw, If you want to get other watts information,
Please do not hesitate to contact us!
Wiring Diagram
1. We offer 3 optional working modes (transfer time≤4ms):
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
Application
Hot Searches