Overall machine structure and control system description
[Main machine] adopts a horizontal structure, and the main structure adopts an overall thickened steel plate structure to ensure the rigidity of the whole machine; the clamps adopt high-quality carbon steel 45 quenching (HR55~65) method, which has a long service life; the installation and disassembly of the specimen are convenient and Fast.
[Main machine] adopts a horizontal structure, and the main structure adopts an overall thickened steel plate structure to ensure the rigidity of the whole machine; the clamps adopt high-quality carbon steel 45 quenching (HR55~65) method, which has a long service life; the installation and disassembly of the specimen are convenient and Fast.
[Drive system] Fully digital ZCTestmart control system drive; adjustable speed, uniform and stable loading.
[Transmission system] Adopts precision reducer transmission to ensure uniformity, stability and transmission accuracy.
[Measurement display system] This machine uses a large-screen liquid crystal display system to simultaneously display the torque T, torsion angle θ, and test speed of the sample. The system can set the torsion angle θ to detect the torque of the specimen, and can also set the torque to detect the torsion angle of the specimen.
[Safety protection system] Overload protection, over-current protection, etc.
Working environment requirements
1 At room temperature within the range of 100C to 350C, the relative humidity is ≤80%;
2 On a stable foundation or workbench;
3 In an environment with no vibration and no corrosive media around;
4 The fluctuation range of the power supply voltage should not exceed ±10% of the rated voltage.
[Transmission system] Adopts precision reducer transmission to ensure uniformity, stability and transmission accuracy.
[Measurement display system] This machine uses a large-screen liquid crystal display system to simultaneously display the torque T, torsion angle θ, and test speed of the sample. The system can set the torsion angle θ to detect the torque of the specimen, and can also set the torque to detect the torsion angle of the specimen.
[Safety protection system] Overload protection, over-current protection, etc.
Working environment requirements
1 At room temperature within the range of 100C to 350C, the relative humidity is ≤80%;
2 On a stable foundation or workbench;
3 In an environment with no vibration and no corrosive media around;
4 The fluctuation range of the power supply voltage should not exceed ±10% of the rated voltage.