Quick Details

Item:
Krohne OPTIFLUX2300F Electromagnetic flow meter
Measuring principle:
Faraday's law of induction
Application range:
Electrically conductive fluids
Primary measured value:
Flow velocity
Secondary measured value:
Volume flow
Diameter OPTIFLUX2050 C:
DN25 to DN1200
Diameter OPTIFLUX2100 C:
DN25 to DN1200
Diameter OPTIFLUX2300 C:
DN25 to DN3000
Remote version with IFC 050 converter:
OPTIFLUX2050 W
Remote version with IFC 100 converter:
OPTIFLUX2100 W

Quick Details

Place of Origin:
Germany
Brand Name:
KROHNE
Model Number:
OPTIFLUX2300F
Item:
Krohne OPTIFLUX2300F Electromagnetic flow meter
Measuring principle:
Faraday's law of induction
Application range:
Electrically conductive fluids
Primary measured value:
Flow velocity
Secondary measured value:
Volume flow
Diameter OPTIFLUX2050 C:
DN25 to DN1200
Diameter OPTIFLUX2100 C:
DN25 to DN1200
Diameter OPTIFLUX2300 C:
DN25 to DN3000
Remote version with IFC 050 converter:
OPTIFLUX2050 W
Remote version with IFC 100 converter:
OPTIFLUX2100 W

Krohne OPTIFLUX2000 OPTIFLUX2100W OPTIFLUX2050W  OPTIFLUX2300F

Electromagnetic flow meter

Product Description

Krohne OPTIFLUX2000 OPTIFLUX2100W OPTIFLUX2050W  OPTIFLUX2300F

Electromagnetic flow meter

1.Reliable solution for the water and wastewater industry

The OPTIFLUX2000 (OPTIFLUX2100C OPTIFLUX2050C OPTIFLUX2300F )is designed to meet the demands for all water and waste water applications including groundwater, potable water, waste water, sludge and sewage, industry water and salt water.

The OPTIFLUX2000 OPTIFLUX2100C OPTIFLUX2050C OPTIFLUX2300C has a field proven and unsurpassed lifetime. This is assured by the fully welded construction, full bore pipe, absence of moving parts and wear resistant liner materials.

The sensor has the widest diameter range available in the market: from DN25 up to DN3000.

1 Robust fully welded construction
2 Diameter range: DN25...DN3000
3 PP, PO and hard rubber liners

2.Highlights Krohne OPTIFLUX2300F Electromagnetic flow meter

• Rugged liners suitable for any water and wastewater application

• Proven and unsurpassed lifetime, huge installed base

• Tamper proof, all welded construction, also available in customer specific constructions

Drinking water approvals including KTW, KIWA, ACS, DVGW, NSF

• Suitable for subsoil installation and constant flooding (IP68)

• Bi-directional flow metering

• Compliant with requirements for custody transfer

(MID MI-001, OIML R49, ISO 4064, EN 14154)

• Standard in house wet calibration of sensors up to diameter DN3000

• Easy installation and commissioning

• No grounding rings with virtual reference option on IFC 300

• In-situ verification with MagCheck

• Extensive diagnostic capabilities

• Maintenance-free

3.Industries Krohne OPTIFLUX2300F Electromagnetic flow meter

• Water

• Wastewater

• Pulp & Paper

• Minerals & Mining

• Iron, Steel & Metals

• Power

4.Applications for Krohne OPTIFLUX2300F Electromagnetic flow meter

• Water abstraction

• Water purification and desalination

• Drinking water distribution networks

• Revenue metering or billing

• Leakage detection

• Irrigation

• Industry water

• Cooling water

• Wastewater

• Sewage and sludge

• Sea water

5. The reliable solution for the water and wastewater industry

From standard to customized

For easy ordering the standard range of the

OPTIFLUX2000F covers all popular sizes, flange

materials and connections (ASME, EN, JIS, AWWA).

But KROHNE does not stop here. Our extensive

engineering department isdedicated to provide

solutions for all specifications not covered by our

standard range. Requests for special sizes, flange

connections, pressure ratings, building lengths, and materials, will alwaysget a serious review.

Whenever possible we will engineer a flow meter

that fits your application.

Easy installation

Fitting the OPTIFLUX 2000 iseasy with the flanged design and standard ISO insertion lengths. To further ease the operation, the OPTIFLUX 2000 can be installed without filters and straighteners. Even grounding rings are not required with the patented "VirtualReference"option on the IFC 300converter.

Installation in measurement chambers subject to (constant) flooding is possible with the IP68 rated version. The chambers can even be completely surpassed if the IP68 version is combined with our special subsoil coating, allowing the OPTIFLUX 2000 to be installed directly in the ground.

Custody transfer

I n combination with the IFC 300 converter the

OPTIFLUX2000 is suitablefor custody transfer

applications. It meets the requirements of OIML R49

and can be verified according to Annex MI-001 of the Measuring Instruments Directive (MID). All water meters for legal metrolog y purposes in Europe require certification under the MID. The EC type examination certificate for the OPTIFLUX 2300 is valid for the compact and the remote version and applies for forward and reverse flow.

6. Technical data for Krohne OPTIFLUX2300F Electromagnetic flow meter

Measuring system

Measuring principle Faraday's law of induction
Application range Electrically conductive fluids
Measured value
Primary measured value Flow velocity

Secondary measured value

Volume flow
Design
Features Fully welded maintenance-free senso
Large diameter range DN25...3000
Rugged liners approvedfor drinking water.

Large standard range but also available in customer specific diameter,
length and pressure rating.

Modular construction

The measurement system consists of a flow sensor and a signal converter. It
is available as compact and as separate version. Additional information can
be found in the documentation of the signal converter

Compact version With IFC 050 converter: OPTIFLUX 2050 C
With IFC 100 converter: OPTIFLUX 2100 C
With IFC 300 converter: OPTIFLUX 2300 C
Remote version In wall (W) mount version with IFC 050 converter: OPTIFLUX 2050 W
In wall (W) mount version with IFC 100 converter: OPTIFLUX 2100 W

In field (F), wall (W) or rack (R) mount version with IFC 300 converter:
OPTIFLUX 2300 F, W or R

Measuring accuracy
Reference conditions Medium: water
Temperature: +10...+30°C / +50...+86°

Operating pressure: 1 bar / 14.5 psi

Inlet section ≥5 DN
Electrical conductivity: ≥300 μS/cm

Maximum measuring error

IFC 050: 0.5% of the measured value above 0.5 m/s; below 0.5 m/s, deviation
±2.5 mm/s

IFC 100: down to 0.3% of the measured value ±1 mm/s
IFC 300: down to 0.2% of the measured value ±1 mm/s
The maximum measuring error depends on the installation conditions
Repeatability ±0.1% of the measured value, minimum 1 mm/s