- Product Details
- {{item.text}}
Quick Details
-
Item:
-
Krohne OPTIFLUX2300F Electromagnetic flow meter
-
Measuring principle:
-
Faraday's law of induction
-
Application range:
-
Electrically conductive fluids
-
Primary measured value:
-
Flow velocity
-
Secondary measured value:
-
Volume flow
-
Diameter OPTIFLUX2050 C:
-
DN25 to DN1200
-
Diameter OPTIFLUX2100 C:
-
DN25 to DN1200
-
Diameter OPTIFLUX2300 C:
-
DN25 to DN3000
-
Remote version with IFC 050 converter:
-
OPTIFLUX2050 W
-
Remote version with IFC 100 converter:
-
OPTIFLUX2100 W
Quick Details
-
Place of Origin:
-
Germany
-
Brand Name:
-
KROHNE
-
Model Number:
-
OPTIFLUX2300F
-
Item:
-
Krohne OPTIFLUX2300F Electromagnetic flow meter
-
Measuring principle:
-
Faraday's law of induction
-
Application range:
-
Electrically conductive fluids
-
Primary measured value:
-
Flow velocity
-
Secondary measured value:
-
Volume flow
-
Diameter OPTIFLUX2050 C:
-
DN25 to DN1200
-
Diameter OPTIFLUX2100 C:
-
DN25 to DN1200
-
Diameter OPTIFLUX2300 C:
-
DN25 to DN3000
-
Remote version with IFC 050 converter:
-
OPTIFLUX2050 W
-
Remote version with IFC 100 converter:
-
OPTIFLUX2100 W
Krohne OPTIFLUX2000 OPTIFLUX2100W OPTIFLUX2050W OPTIFLUX2300F
Electromagnetic flow meter
Krohne OPTIFLUX2000 OPTIFLUX2100W OPTIFLUX2050W OPTIFLUX2300F
Electromagnetic flow meter
1.Reliable solution for the water and wastewater industry
The OPTIFLUX2000 (OPTIFLUX2100C OPTIFLUX2050C OPTIFLUX2300F )is designed to meet the demands for all water and waste water applications including groundwater, potable water, waste water, sludge and sewage, industry water and salt water.
The OPTIFLUX2000 OPTIFLUX2100C OPTIFLUX2050C OPTIFLUX2300C has a field proven and unsurpassed lifetime. This is assured by the fully welded construction, full bore pipe, absence of moving parts and wear resistant liner materials.
The sensor has the widest diameter range available in the market: from DN25 up to DN3000.
1 Robust fully welded construction
2 Diameter range: DN25...DN3000
3 PP, PO and hard rubber liners
2.Highlights Krohne OPTIFLUX2300F Electromagnetic flow meter
• Rugged liners suitable for any water and wastewater application
• Proven and unsurpassed lifetime, huge installed base
• Tamper proof, all welded construction, also available in customer specific constructions
Drinking water approvals including KTW, KIWA, ACS, DVGW, NSF
• Suitable for subsoil installation and constant flooding (IP68)
• Bi-directional flow metering
• Compliant with requirements for custody transfer
(MID MI-001, OIML R49, ISO 4064, EN 14154)
• Standard in house wet calibration of sensors up to diameter DN3000
• Easy installation and commissioning
• No grounding rings with virtual reference option on IFC 300
• In-situ verification with MagCheck
• Extensive diagnostic capabilities
• Maintenance-free
3.Industries Krohne OPTIFLUX2300F Electromagnetic flow meter
• Water
• Wastewater
• Pulp & Paper
• Minerals & Mining
• Iron, Steel & Metals
• Power
4.Applications for Krohne OPTIFLUX2300F Electromagnetic flow meter
• Water abstraction
• Water purification and desalination
• Drinking water distribution networks
• Revenue metering or billing
• Leakage detection
• Irrigation
• Industry water
• Cooling water
• Wastewater
• Sewage and sludge
• Sea water
5. The reliable solution for the water and wastewater industry
From standard to customized
For easy ordering the standard range of the
OPTIFLUX2000F covers all popular sizes, flange
materials and connections (ASME, EN, JIS, AWWA).
But KROHNE does not stop here. Our extensive
engineering department isdedicated to provide
solutions for all specifications not covered by our
standard range. Requests for special sizes, flange
connections, pressure ratings, building lengths, and materials, will alwaysget a serious review.
Whenever possible we will engineer a flow meter
that fits your application.
Easy installation
Fitting the OPTIFLUX 2000 iseasy with the flanged design and standard ISO insertion lengths. To further ease the operation, the OPTIFLUX 2000 can be installed without filters and straighteners. Even grounding rings are not required with the patented "VirtualReference"option on the IFC 300converter.
Installation in measurement chambers subject to (constant) flooding is possible with the IP68 rated version. The chambers can even be completely surpassed if the IP68 version is combined with our special subsoil coating, allowing the OPTIFLUX 2000 to be installed directly in the ground.
Custody transfer
I n combination with the IFC 300 converter the
OPTIFLUX2000 is suitablefor custody transfer
applications. It meets the requirements of OIML R49
and can be verified according to Annex MI-001 of the Measuring Instruments Directive (MID). All water meters for legal metrolog y purposes in Europe require certification under the MID. The EC type examination certificate for the OPTIFLUX 2300 is valid for the compact and the remote version and applies for forward and reverse flow.
6. Technical data for Krohne OPTIFLUX2300F Electromagnetic flow meter
Measuring system
Measuring principle | Faraday's law of induction |
Application range | Electrically conductive fluids |
Measured value | |
Primary measured value | Flow velocity |
Secondary measured value |
Volume flow |
Design | |
Features | Fully welded maintenance-free senso |
Large diameter range DN25...3000 | |
Rugged liners approvedfor drinking water. | |
Large standard range but also available in customer specific diameter,
|
|
Modular construction |
The measurement system consists of a flow sensor and a signal converter. It
|
Compact version | With IFC 050 converter: OPTIFLUX 2050 C |
With IFC 100 converter: OPTIFLUX 2100 C | |
With IFC 300 converter: OPTIFLUX 2300 C | |
Remote version | In wall (W) mount version with IFC 050 converter: OPTIFLUX 2050 W |
In wall (W) mount version with IFC 100 converter: OPTIFLUX 2100 W | |
In field (F), wall (W) or rack (R) mount version with IFC 300 converter:
|
|
Measuring accuracy | |
Reference conditions | Medium: water |
Temperature: +10...+30°C / +50...+86° | |
Operating pressure: 1 bar / 14.5 psi |
|
Inlet section ≥5 DN | |
Electrical conductivity: ≥300 μS/cm | |
Maximum measuring error |
IFC 050: 0.5% of the measured value above 0.5 m/s; below 0.5 m/s, deviation
|
IFC 100: down to 0.3% of the measured value ±1 mm/s | |
IFC 300: down to 0.2% of the measured value ±1 mm/s | |
The maximum measuring error depends on the installation conditions | |
Repeatability | ±0.1% of the measured value, minimum 1 mm/s |