High temperature resistanceCorrosion resistanceSafety protectionCharge stabilization
- Product Details
- {{item.text}}
Quick Details
-
Output Power:
-
7kW/11kw/22KW
-
Input Voltage:
-
230/440V
-
Product name:
-
EV Charging Station (WallBox)
-
Application:
-
AC Home Charging
-
Certificate:
-
CE ROHS
Quick Details
-
Place of Origin:
-
Henan, China
-
Model Number:
-
HY01-AC-N007
-
Brand Name:
-
Orld Blossom
-
Output Power:
-
7kW/11kw/22KW
-
Input Voltage:
-
230/440V
-
Product name:
-
EV Charging Station (WallBox)
-
Application:
-
AC Home Charging
-
Certificate:
-
CE ROHS
Product Paramenters
Model
|
HY01-AC-N007
|
HY01-AC-N011
|
HY01-AC-N022
|
HY01-AC-N030
|
||||
Input Voltage
|
220Vac±10%
|
380Vac±10%
|
380Vac±10%
|
380Vac±10%
|
||||
Working Frequency
|
50 /60 Hz
|
|
|
|
||||
Power Factor
|
≥0.99
|
|
|
|
||||
Input Current
|
32A
|
32A
|
32A
|
50A
|
||||
Output Power
|
7KW
|
11KW
|
22KW
|
30KW
|
||||
Output Voltage
|
200-750VDC
|
|
|
|
||||
Max Current
|
20A
|
25-33A
|
35-55A
|
50-100A
|
||||
Work environment
|
|
|
|
|
||||
Temperature range
|
‘-40~85℃、25℃type; Intelligent derating when shell temperature exceeds 70℃
|
|
|
|
||||
Humidity range
|
5~90RH%; non-condensation
|
|
|
|
||||
Altitude
|
2000m
|
|
|
|
||||
Automobile pile column
|
50*1500*170mm
|
50*1500*170mm
|
50*1500*170mm
|
50*1500*170mm
|
Storage environment
|
|
|
|
|
||||
Temperature range
|
‘-20~50℃;25℃(type)
|
|
|
|
||||
Humidity range
|
5~95RH%; 25RH%(type); non-condensation
|
|
|
|
||||
Altitude
|
2000m
|
|
|
|
||||
Single size(mm)
|
W:240×400×60mm
|
W:240×400×60mm
|
W:240×400×60mm
|
W:240×400×60mm
|
||||
Weight
|
25kg
|
35kg
|
42kg
|
53kg
|
||||
Number of charging guns
|
1 or 2
|
1
|
1
|
1
|
||||
IP Level
|
IP54
|
|
|
|
||||
Human Machine Interface
|
4.8-inch touchscreen display
|
|
|
|
||||
Charging mode
|
Family version:plug and charge,RFID, Password.
Charging mode Network version: RFID,VIN code, Wechat, Alipay, Mobile App.Wechat App etc, international model can equip with DCPP. |
|
|
|
||||
Standard
|
EN61851-1,JEVSG 105
|
|
|
|
||||
Protocol
|
CHAdeMO 2.0/DIN 70121, OCPP 1.6(JSON or SOAP), ISO 15118
|
|
|
|
Customer purchase instructions:
1, our company can provide two styles, model HY01-AC-- and model HY02-AC--
2, both styles have a home version and a commercial operation version.
3, you tell customer service at the time of purchase, we will provide products according to your requirements.
Products Description
High quality copper cable
LED liquid crystal display
Voltage, current, charging time, battery capacity digital display,
03/
Charging gun
safety relay
50A safety relay
Safe and durable
High temperature
resistance
Installation Instructions
Installation preparation
Installation site instructions:
1. Charging piles should not be installed in places with low terrain and possible wateraccumulation,
2.Require good ventilation;
3.The installation position shall ensure the observation indicator light and convenient operation;
4. Non-CPU disconnection equipment shall keep the site signal in good condition;
Wall-mounted AC pile
Confirm the installation position and mark it. The height of the center of the charging pile from the ground should be at least 1.3 meters. Mark the hole position with a pen on the wall where the equipment needs to be installed, and use an electric drill to mark the hole position and punch holes separately. Install 12*60 standard expansion bolts at the drilling hole, Hammer tightly with safety hammer, and fix the bottom plate on the wall with screws.
1. Charging piles should not be installed in places with low terrain and possible wateraccumulation,
2.Require good ventilation;
3.The installation position shall ensure the observation indicator light and convenient operation;
4. Non-CPU disconnection equipment shall keep the site signal in good condition;
Wall-mounted AC pile
Confirm the installation position and mark it. The height of the center of the charging pile from the ground should be at least 1.3 meters. Mark the hole position with a pen on the wall where the equipment needs to be installed, and use an electric drill to mark the hole position and punch holes separately. Install 12*60 standard expansion bolts at the drilling hole, Hammer tightly with safety hammer, and fix the bottom plate on the wall with screws.
Clamp the groove behind the pile body into the adhesive hook above the bottom plate and fix it with screws to complete the installation.
Installation of column type AC pile:
Please confirm the installation position and mark it place the charging column in place at the required installation site, and
install the backboard and terminal. Introduce the external power incoming line from the inlet hole at the bottom of the column,and fix the column with expansion bolts.
Please confirm the installation position and mark it place the charging column in place at the required installation site, and
install the backboard and terminal. Introduce the external power incoming line from the inlet hole at the bottom of the column,and fix the column with expansion bolts.
Clamp the groove behind the pile body into the adhesive hook above the bottom plate and fix it with screws to complete the installation.
Product Application
Hot Searches