- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
KYN28A-12
-
Product Name:
-
KYN28A-12 12kV Ac Metal-enclosed Medium Voltage Switchgear
-
Size:
-
800*1660*2300
-
Rated Voltage:
-
12KV
-
Warranty:
-
5 Years
-
Standard:
-
IEC60298
-
Protection Level:
-
IP4X
-
OEM:
-
Offered
-
Application:
-
Electric Power Transmission
-
Certificate:
-
ISO9001 CCC IEC Test report
-
Type:
-
Distribution Box Electrical Boxes
-
Color:
-
Customization
-
Voltage:
-
12kV
Quick Details
-
Current:
-
630 to 3150A
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
JUNLAN
-
Model Number:
-
KYN28A-12
-
Product Name:
-
KYN28A-12 12kV Ac Metal-enclosed Medium Voltage Switchgear
-
Size:
-
800*1660*2300
-
Rated Voltage:
-
12KV
-
Warranty:
-
5 Years
-
Standard:
-
IEC60298
-
Protection Level:
-
IP4X
-
OEM:
-
Offered
-
Application:
-
Electric Power Transmission
-
Certificate:
-
ISO9001 CCC IEC Test report
-
Type:
-
Distribution Box Electrical Boxes
-
Color:
-
Customization
-
Voltage:
-
12kV
Product Paramenters
Product Name
|
KYN28A-12 Ac Metal-enclosed Switchgear Equipment
|
Brand Name
|
JULAN
|
Rated Voltage
|
3.6kv,7.2kv ,12KV
|
Rated current
|
630,1250,1600,2000,2500,3150.4000
|
4s short time withstand current(kA) |
16.20,25,31,31.5,40,50
|
Rated peak withstand current(kA)
|
50,63,80,100,125
|
Rated frequency
|
50/60Hz
|
Voltage Level
|
Medium Voltage
|
Protection level |
Enclosure IP4X,partition of each compartment is IP2X
|
phase
|
AC 3 phase
|
Products Description
Features
KYN28A-12(GZS1) air-insulated metal-clad withdrawable switchgear (hereinafter as “switchgear”) is a necessary indoor power
distribution equipment 3-phase AC 50Hz. It is mainly used to receive and distribute 3-24kV network electrical and control
protection and monitoring to line circuit. Relay chamber panel can install in various types of microprocessor based relay
protection device , and can realize the intelligent control system, with remote control, telemetry, remote communication and
remote transfer function, through the CAN communication interface with fieldbus control network to prevent the mal-operation of
circuit breaker, to prevent pushing and pulling handcart with load, to prevent grounding switch closed with charged, to prevent
the grounding switch in the grounding position transmission and to prevent into live space, which is referred to as the
"five-anti" function. The cabinet is equipped with VS1 (ZN63), ZN12V vacuum circuit breaker, also can be equipped with imported
VD4 vacuum circuit breaker and VC series vacuum contactor. The switchgear meet the requirements of standard
IEC62271-200,IEC62271-100 etc.
1. Ambient temperature:-10oC ~ +40oC;
2. Altitude: Not exceed 1000m above sea level;
3. Ambient humidity: Daily average RH ≤ 95%; Monthly average RH ≤ 90%
Water vapor pressure:Daily average RH ≤ 2.2kPa; Monthly average RH ≤ 1.8kPa;
There may be condensation, when the temperature plunged with filth, the products apply to the
following two conditions more severe than normal
(1). Condensation not frequently(average monthly not more than two times) with mild pollution;
(2). There is no condensation (average yearly not more than two times) with serious pollution;
4.No violent vibration, bumps and vertical gradient not more than 8° of place
distribution equipment 3-phase AC 50Hz. It is mainly used to receive and distribute 3-24kV network electrical and control
protection and monitoring to line circuit. Relay chamber panel can install in various types of microprocessor based relay
protection device , and can realize the intelligent control system, with remote control, telemetry, remote communication and
remote transfer function, through the CAN communication interface with fieldbus control network to prevent the mal-operation of
circuit breaker, to prevent pushing and pulling handcart with load, to prevent grounding switch closed with charged, to prevent
the grounding switch in the grounding position transmission and to prevent into live space, which is referred to as the
"five-anti" function. The cabinet is equipped with VS1 (ZN63), ZN12V vacuum circuit breaker, also can be equipped with imported
VD4 vacuum circuit breaker and VC series vacuum contactor. The switchgear meet the requirements of standard
IEC62271-200,IEC62271-100 etc.
Work Environment
2. Altitude: Not exceed 1000m above sea level;
3. Ambient humidity: Daily average RH ≤ 95%; Monthly average RH ≤ 90%
Water vapor pressure:Daily average RH ≤ 2.2kPa; Monthly average RH ≤ 1.8kPa;
There may be condensation, when the temperature plunged with filth, the products apply to the
following two conditions more severe than normal
(1). Condensation not frequently(average monthly not more than two times) with mild pollution;
(2). There is no condensation (average yearly not more than two times) with serious pollution;
4.No violent vibration, bumps and vertical gradient not more than 8° of place