- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
HEYI
-
Accuracy Class:
-
1%
-
Output Voltage:
-
80-260V
-
Operating Temperature:
-
-10-60degree
-
Dimensions:
-
4.9*4.7*5.3CM
-
Voltage Range:
-
AC50-300V
-
Active power:
-
0-30000W
-
Current Range:
-
AC0-99.99A
-
Frequence:
-
45-65hz
-
Electric Energy:
-
0-99999kw
Quick Details
-
Phase:
-
Single Phase
-
Measuring Energy Range:
-
0-99999kwh
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
HEYI
-
Accuracy Class:
-
1%
-
Output Voltage:
-
80-260V
-
Operating Temperature:
-
-10-60degree
-
Dimensions:
-
4.9*4.7*5.3CM
-
Voltage Range:
-
AC50-300V
-
Active power:
-
0-30000W
-
Current Range:
-
AC0-99.99A
-
Frequence:
-
45-65hz
-
Electric Energy:
-
0-99999kw
Product Description




product description
OX-D48-2058 DIN-Rail Multi-Function Digital Meter
User Guide
OX-D48-2058 DIN-rail multi-function Digital meter can measure AC voltage, AC current, power factor, active
power, electric energy and power frequency. The meter display part adopts the color high-definition LCD screen
Technical Indicators
1.Accuracy: 1%±2 words
2.Range: AC voltage : AC 50.0-300.0V/ AC 250.0-450.0V ( You should select the one type of meter in your order ).
AC current:AC0.0-99.99A(the accuracy is0.01Awhen measure signal lower than100A, when measure
signal higher than100A, the meter will show100.0A)
Power frequency: 45.00-65.00Hz
Power factor: 0.00 - 1.00PF
Active power: 0-45000W ( The display accuracy is 0.1W when the active power between 0 and 9999.9W, otherwise the accuracy is 1W)
Electric energy: 0-99999kwh (The display accuracy is 0.01kwh when the electric energybetween0-999.99kwh,0.1kwhwhentheelectric
energy between 10000.0-9999.9kwh,0.01kwh when the electric energy between 100000-99999kwh
3.Speed: 2 times per second
4.Size: 49×47×52
5.Hole: diameter Φ22mm
6.Autosave: When the meter power is off, the current electric energy value will be automatically saved . the meter
will read the value after the next power on and going to keep adding to the saved value.number.
Application Method
1.According to the wiring diagram, connect the plug two-wire of the current transformer to transformer the input on
meter, make the current return conductor across the hold which in the middle of the current transformer.
2.Connect the voltage measurement to the voltage input terminal of the meter. Then turn on and measure the voltage to start to
read the measure result.
3.The electric energy reset button is on the right-bottom of the meter, you can press the button with a needle last for
4. second, then the electric energy will be reset.
Attention
The meter with measure range between 250-450V can only use to measure 50Hz AC city electricity, it will be
destroyed when use to measure square wave, output of inverter and correction sine wave. The meter with measure range between
50-300 not affected.
User Guide
OX-D48-2058 DIN-rail multi-function Digital meter can measure AC voltage, AC current, power factor, active
power, electric energy and power frequency. The meter display part adopts the color high-definition LCD screen
Technical Indicators
1.Accuracy: 1%±2 words
2.Range: AC voltage : AC 50.0-300.0V/ AC 250.0-450.0V ( You should select the one type of meter in your order ).
AC current:AC0.0-99.99A(the accuracy is0.01Awhen measure signal lower than100A, when measure
signal higher than100A, the meter will show100.0A)
Power frequency: 45.00-65.00Hz
Power factor: 0.00 - 1.00PF
Active power: 0-45000W ( The display accuracy is 0.1W when the active power between 0 and 9999.9W, otherwise the accuracy is 1W)
Electric energy: 0-99999kwh (The display accuracy is 0.01kwh when the electric energybetween0-999.99kwh,0.1kwhwhentheelectric
energy between 10000.0-9999.9kwh,0.01kwh when the electric energy between 100000-99999kwh
3.Speed: 2 times per second
4.Size: 49×47×52
5.Hole: diameter Φ22mm
6.Autosave: When the meter power is off, the current electric energy value will be automatically saved . the meter
will read the value after the next power on and going to keep adding to the saved value.number.
Application Method
1.According to the wiring diagram, connect the plug two-wire of the current transformer to transformer the input on
meter, make the current return conductor across the hold which in the middle of the current transformer.
2.Connect the voltage measurement to the voltage input terminal of the meter. Then turn on and measure the voltage to start to
read the measure result.
3.The electric energy reset button is on the right-bottom of the meter, you can press the button with a needle last for
4. second, then the electric energy will be reset.
Attention
The meter with measure range between 250-450V can only use to measure 50Hz AC city electricity, it will be
destroyed when use to measure square wave, output of inverter and correction sine wave. The meter with measure range between
50-300 not affected.
Specification
item
|
value
|
Place of Origin
|
China
|
|
Zhejiang
|
Brand Name
|
HEYI
|
Model Number
|
|
Display Type
|
Digital Only
|
Phase
|
Single Phase
|
Measuring Energy Range
|
0-99999kwh
|
Accuracy Class
|
1%
|
Output Voltage
|
80-260V
|
Operating Temperature
|
-10-60degree
|
Dimensions
|
4.9*4.7*5.3CM
|
Voltage Range
|
AC50-300V
|
Active power
|
0-30000W
|
Current Range
|
AC0-99.99A
|
Frequence
|
45-65hz
|
Electric Energy
|
0-99999kw
|
Hot Searches