Products
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch

Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch

FOB Reference Price: Get Latest Price
≥5 Pieces
US $6.25
≥25 Pieces
US $5.75
≥100 Pieces
US $5.25
≥500 Pieces
US $4.75
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
Pulse trigger cycle time delay relay module
Max. Current:
10A
Working voltage:
DC5V/12V/24V
Input signal:
NPN/PNP/Switch
Standby current:
10mA
Output mode:
Switch
Time adjustable:
0.01s to 999 minutes
Size:
70*45*28.6mm
Time accuracy:
0.01s
Contact mode:
One open and one close
Set method:
Button set with power off
Certification:
other

Quick Details

Max. Voltage:
24V
Place of Origin:
Guangdong, China
Brand Name:
Taidacent
Model Number:
Pulse trigger cycle time delay relay module
Max. Current:
10A
Working voltage:
DC5V/12V/24V
Input signal:
NPN/PNP/Switch
Standby current:
10mA
Output mode:
Switch
Time adjustable:
0.01s to 999 minutes
Size:
70*45*28.6mm
Time accuracy:
0.01s
Contact mode:
One open and one close
Set method:
Button set with power off
Certification:
other
Taidacent 5V 12V 24V Digital Timer Switch Adjustable Time Delay Relay Module Trigger Cycle Timer Delay On Off Relay Switch
Product Description
1. This product comes with 38 common working modes, which can realize power-on delay on/delay off timing cycles and other scenarios. For details, please refer to the function introduction of P11-P48 on the detail page, which has a wider range of applications. 2. The large time range of 0.01s-999 minutes is adjustable, and the applicability is wider. 3. The design of the module adopts diodes to prevent reverse connection, and the reverse connection does not burn. The input and output optocouplers are electrically isolated to make the product performance more stable. 4. The SMT automatic horizontal placement process is adopted in a large area to make the product consistency and higher quality Quantitative performance is better. 5. Using 0.36-inch 4A common cathode digital tube, the display content is more intuitive and clear, and the button-type operation is more convenient. 6. Using relays, the mechanical failure rate is greatly reduced, and the service life can reach 250,000 times, which is significantly longer than the 100,000 times of other brands of relays.
Specification
item
value
Model Number
Pulse trigger cycle time delay relay module
Max. Current
10A
Max. Voltage
24V
Working voltage
DC5V/12V/24V
Input signal
NPN/PNP/Switch
Standby current
10mA
Output mode
Switch
Time adjustable
0.01s to 999 minutes
Size
70*45*28.6mm
Time accuracy
0.01s
Contact mode
One open and one close
Set method
Button set with power off

Function

P-11: Jog (close the signal relay, and disconnect the relay when the signal disappears) P-12: Self-locking (give a signal to the relay to pull in, and then give a signal to disappear the relay to disconnect) P-13: When the signal is given, the relay will automatically stop at the time of closing A, and the trigger will be invalid during the delay period. P-14: When the signal is given, the time for the relay to pull in A will automatically stop, and re-time will be triggered during the delay period. P-15: When the signal is given, the time for the relay to pull in A will automatically stop, and the superposition timing will be triggered during the delay period. P-16: When the signal is given, the relay will automatically stop when the A time is closed, and the reset will be triggered during the delay period. P-17: Give the signal → the relay is closed, after the input signal is disconnected, start timing A time is disconnected, during the delay period, the signal remains output again, and the timing stops P-18: After the power is turned on, the relay will be pulled in immediately, and will be turned off after a delay of A time until the next power-on. P-21: Give signal, after delay A time → relay pulls in. P-22: Give a continuous signal, after the time exceeds A → the relay is pulled in, the signal disappears, and the relay is disconnected. P-23: After the signal disappears for more than A time, the relay is pulled in, there is a signal, and the relay is disconnected. P-24: There is a signal. After the A time is exceeded, the relay pulls in. After the signal disappears and exceeds the A time, the relay is disconnected. P-25: There is a signal. After the time exceeds A, the relay is closed. After the signal exceeds the time A again, the relay is disconnected. P-26: There is a signal, the relay will stop after pulling in A for a time, and when the signal disappears, the relay will stop after pulling in A again. P-27: There is a pulse signal detected, the relay does not work, there is no pulse signal, the relay delays A time to pull in.
P-28: Delay A time after power-on, the relay will pull in until power-off. P-31: After the power is turned on, the relay pulls in the A time, disconnects the B time, and loops infinitely until the power is turned off. P-32: There is a signal, start the P-31 infinite loop, the signal disappears, the loop is terminated. P-33: Give the signal once, start the P-31 infinite loop, give the signal again to terminate the loop. P-34: After the power is turned on, after the delay time A, the relay pulls in, and the pull-in time B is disconnected. P-35: There is a signal, after a delay of time A, the relay is pulled in, and the time of pull-in B is disconnected. P-36: There is a signal, after a delay of time A, the relay pulls in for time B and disconnects, the signal disappears, and the timer is cleared and stopped. P-37: If there is a signal, the relay will automatically stop when the A time is closed, and then time the B time after the stop. The signal triggering is invalid within the A+B time.
P-38: If there is a signal, the relay will automatically stop when the A time is pulled in. After the time is stopped, the time B will be counted again, and the time will be stopped when the A is pulled in again. P-41: No action when there is a signal, trigger when the signal disappears, and disconnect after the output starts A time. P-42: The signal disappears, after the delay time A, the output starts, and the work ends after the time B. P-43: The signal disappears, after the time A exceeds the output, the output starts, and the work ends after the time B. P-44: After the power is turned on, the output starts A time, stops B time, and ends the cycle C times. P-45: Power on and no action, start A time for signal output, stop B time, and cycle C times to disconnect. Give the signal again and do it again. P-46: After the signal is given more than A times, the relay output starts → maintains the output. P-47: After the signal is given more than A times, the output starts and stops for B time. P-48: In C seconds, after continuously giving the signal more than A times, the output starts and stops for B seconds.

Button setting instructions The power-on display "----" indicates that it enters the standby state

Function settings: Press K1 for the first time, it takes more than 1 second to be effective, to prevent false triggering. Display: P-11: K2 adjusts the main mode, K3K4 adjusts the function. Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit) Press K1 for the third time, the screen displays: BO01: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) Press K1 for the fourth time, it will display "------" to enter the standby state Press K4 in standby state to permanently turn off/on the display and switch to low power mode

Decimal point time unit description: X.XX decimal point is in the hundreds place, timing range: 0.01 seconds ~ 9.99 seconds XX.X The decimal point is in the ten place, the timing range: 0.1 seconds ~ 99.9 seconds XXX has no decimal point, timing range: 1 second to 999 seconds XXX. The decimal point is in ten places, the timing range: 1 minute to 999 minutes