- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
Hongjin
-
Product name:
-
Sulfur dioxide corrosion test chamber
-
Standard test:
-
ACSS,SOAK,DRYAIR.HUMI,ROOMAIR
-
Humidity range:
-
60% ~ 95%RH (temperature at RT+10t ~ 70b )
-
Test temperature:
-
5°C ~ +80°C
-
Keyword:
-
Corrosion Spray Test Chamber
-
MOQ:
-
1
-
Salt spray temperature:
-
5°C ~ 50°C (CASS)
-
Salt solution temperature:
-
RT+10°C ~ 60°C
-
Dry air temperature:
-
RT+10°C ~ 70°C
-
Power supply:
-
AC380V
Quick Details
-
Warranty:
-
1 Year
-
Power:
-
Electronic
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Hongjin
-
Product name:
-
Sulfur dioxide corrosion test chamber
-
Standard test:
-
ACSS,SOAK,DRYAIR.HUMI,ROOMAIR
-
Humidity range:
-
60% ~ 95%RH (temperature at RT+10t ~ 70b )
-
Test temperature:
-
5°C ~ +80°C
-
Keyword:
-
Corrosion Spray Test Chamber
-
MOQ:
-
1
-
Salt spray temperature:
-
5°C ~ 50°C (CASS)
-
Salt solution temperature:
-
RT+10°C ~ 60°C
-
Dry air temperature:
-
RT+10°C ~ 70°C
-
Power supply:
-
AC380V
specification
Application scope:
This equipment is widely used in aerospace, automobiles and motorcycles, military equipment, electrical and electronics, fire and security, chemical industry and metallurgy, quality inspection and measurement, postal and telecommunications, shipbuilding and railways and other enterprises and institutions as well as universities and scientific research institutions.
product description:
This equipment is used to test the protective layers of electrical and electronic products, electroplating products and various metal products. It is used to assess the ability of materials and their protective layers to resist corrosive gases, and to compare the process quality of similar protection. It is a The artificial simulated gas corrosion test is to use sulfur dioxide gas to accelerate corrosion tests on materials or products under a certain temperature and relative humidity environment to test and compare the degree of damage suffered by the product's protective layer within a certain time range. It can also be used to evaluate the ability of certain products to resist corrosion by corrosive gases. The test results show that a lot of human, financial and material resources have been saved.
Reference standard:
DIN 50018-2013 "Sulfur dioxide corrosion test in saturated environment" GB/T 2423.33-2005 "Environmental testing of electrical and electronic products Part 2: Test method testing Kca: High concentration sulfur dioxide test》 GB/T 9789-2008 "Sulfur dioxide corrosion test of metals and other inorganic coatings under normal condensation conditions" GB 25972-2010 "Gas fire extinguishing systems and components - Sulfur dioxide corrosion test" QB/T 3830-1999 "Corrosion resistance test method and sulfur dioxide test method for metal coatings and chemical treatment layers of light industrial products" GB/T 5170.11-2008 Inspection methods for environmental testing equipment for electrical and electronic products Corrosive gas testing equipment As well as international standards ISO6988-2000, European and American UL639, UL294 and
Product Paramenters
Sulfur dioxide test chamber parameters:
|
|
|
Specifications and models:
|
HJ-250 type
|
|
Studio size:
|
600×900×500 (mm) (depth×width×height)
|
|
temperature range:
|
Room temperature~50℃
|
|
Heating rate:
|
0.1~1℃/min
|
|
Humidity range:
|
85~98%R·H (display value)
|
|
Temperature uniformity:
|
≤±2℃
|
|
Temperature fluctuation:
|
≤±0.5℃
|
|
Timing range:
|
0-9999 H/M/S (adjustable)
|
|
Number of air changes:
|
1 time/day (adjustable)
|
|
Gas purity:
|
99%
|
|
Gas generation method:
|
cylinder method
|
|
Sulfur dioxide gas concentration:
|
0.1~1% (volume percentage)
|
|
Air pressure:
|
0.2~0.4mPa
|
|
Uniform load-bearing inside:
|
≤100KG
|
|
Ambient temperature:
|
Normal temperature~35℃
|
|
environment humidity:
|
<75%
|
|
Power requirements:
|
AC380V/50HZ
|
|
Pre-installed power:
|
9KW (including acid treatment tank power)
|
Acid treatment tank (exhaust gas treatment device) parameters:
|
|
|
|
|
model:
|
HJ-200
|
Internal dimensions:
|
D600×W600×H550mm
|
temperature range:
|
Room temperature~60℃
|
Temperature deviation:
|
≤±2℃
|
Temperature fluctuation:
|
≤±0.5℃
|
pH meter display range:
|
0~14
|
Display range of pH value of waste gas after treatment:
|
6~9
|
Chemical reagents:
|
Sodium hydroxide of analytical grade, activated carbon and deionized distilled water (prepared by customer)
|
Gas concentration processing range:
|
0~1% (volume ratio)
|
Gas detector range:
|
0-200ppm
|
voltage:
|
AC220V 50HZ
|
Installed power approx:
|
3KW
|
Products Description
Hot Searches