Products
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer
DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer

DW-XRD-Y3000 poron foam poron xrd X-Ray Diffractometer

FOB Reference Price: Get Latest Price
≥1 Pieces
US $20000
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Rated power:
3kW
Tube voltage:
10-60kV
Tube current:
5-80mA
X-ray tuble:
glass tube,ceramic tube,ripple ceramic tube:Cu,Fe,Co,Cr,Mo etc
X-ray tuble Power:
2kW
Focus size:
1 x 10mm or 0.4 x 14mm or 2 x 12mm
Stability:
≤0.01%
Goniometer structure:
Horizontal ( 0-2 0)
Radius of diffraction:
185mm
Scanning range:
0-164

Quick Details

Warranty:
1 year
Place of Origin:
Shanghai, China
Brand Name:
Drawell
Rated power:
3kW
Tube voltage:
10-60kV
Tube current:
5-80mA
X-ray tuble:
glass tube,ceramic tube,ripple ceramic tube:Cu,Fe,Co,Cr,Mo etc
X-ray tuble Power:
2kW
Focus size:
1 x 10mm or 0.4 x 14mm or 2 x 12mm
Stability:
≤0.01%
Goniometer structure:
Horizontal ( 0-2 0)
Radius of diffraction:
185mm
Scanning range:
0-164
Product Description
DW-3000 XRD Working conditions 1. Host power supply, three-phase five-wire system single 220V (two sets, different phases), each phase current 20A(wire diameter 6mm²), the distribution box has at least 2 sets of air switches above C32 (including one set for computer), the distribution box is no more than 4 meters away from the location of the host; 2.The grounding line resistance ≤4 Ω; 3.The indoor temperature should be kept at 20℃±5℃ 4.The power supply circuit shall not be interfered by strong electric equipment; 5.Indoor need to prevent static electricity, dust, shock, noise (less than 50 db); 6.The indoor relative temperature should be controlled below 70% (it is recommended to install air conditioner or dehumidifier); 7.Indoor should have water supply and drainage
Configuration List
Part
Element
Unit
Qty.


X-Ray High Voltage Generator
1) 1505 High Voltage Transformer
set
1
2) DW-75kV High Voltage Cable
piece
1
3) 9850 Control panel
set
1
4) 9820 High voltage control unit
1
5) 9830 Control gate
1
6) 9810 System Case
1
7) 9840 Main power cable
piece
1
8) X-ray tube 2kW Cu, Focus size 1×10mm²
piece
1
9) 3306 Tube holder
set
1
10) 9924 X-ray Protective cover
1


Angle Measuring System
1) 3501 Goniometer
set
1
2) Goniometer layer board
1
3) Powder sample plate with blind Holes
piece
20
4) Powder sample plate with through holes
10
5) Micronutrient powder sample board
10
6) Zero setting sample piece, double-knife edge slit
piece
1
7) Standard ruler, watch oil
piece
1
8) Filter Ni
piece
1
9) Slit
set
1

Recording and Controlling Unit
1) 2013 Recording and controlling units
set
1
2) CH132 Scintillation counter
set
1
3) Counter cable
piece
1
4) Stepping motor cable
2
5) Interface cable
1
Circulating Water Cooling System
1) DW-ZFB-3000 Cooling device
set
1
2) 9509 Power cable
piece
1
3) Water pipe 6 meters
piece
2
4) Water relay cable
piece
1

Computer
1) INTEL Pentium G2030, RAM 2G ,500G Hard disk 19″LCD
set
1
2) Canon LBP6018 Laser printer
1
Technical Material
1) DW-Y3000 X-ray diffractometer user manual
piece
1
2) DW-ZFB-3000 Cooling device user manual
1
Spare Parts
1) ring rubber blanket
piece
4
2) Fuse 2A 3A 6A
piece
10
Application Field
Certificate
APP
Post My RFQ
WhatsApp
+86-17326049340