- Product Details
- {{item.text}}
Quick Details
-
Product Name:
-
Picosecond+808 Laser
-
Laser type:
-
Semiconductor laser(755nm+808nm+1064nm)
-
Screen Size:
-
10.4 Inch
-
Laser bar:
-
600W/800W/1000W
-
Energy density:
-
1-50J/cm2 50*2.4=120J(Deviations+2%)
-
Pulse width range:
-
1-20ms
-
Spot size:
-
12*20mm
-
Frequency:
-
1-10HZ
-
Cooling System:
-
Semiconductor+built-in water+Air Cooling triple cooling systems
-
Fuse specification:
-
05x25 10A
Quick Details
-
Place of Origin:
-
Shaanxi, China
-
Brand Name:
-
OEM ODM
-
Model Number:
-
P227
-
Product Name:
-
Picosecond+808 Laser
-
Laser type:
-
Semiconductor laser(755nm+808nm+1064nm)
-
Screen Size:
-
10.4 Inch
-
Laser bar:
-
600W/800W/1000W
-
Energy density:
-
1-50J/cm2 50*2.4=120J(Deviations+2%)
-
Pulse width range:
-
1-20ms
-
Spot size:
-
12*20mm
-
Frequency:
-
1-10HZ
-
Cooling System:
-
Semiconductor+built-in water+Air Cooling triple cooling systems
-
Fuse specification:
-
05x25 10A
Laser Safety
1. The eyebrow washing machine is classified as Class 4 laser products according to the safety classification of laser radiation!
2. The laser is invisible infrared light, of which the laser with a wavelength of 532nm is green dazzling visible light. The operator should wear special protective goggles with a wavelength range of 200-1080nm!
3. The laser window is located at the end of the pistol head aiming, and the laser radiation emitted by this window should be avoided!
4. Never look directly at the end port of the pistol head and any reflected laser beam!
5. Easy and explosive narcotics, liquids, gases (such as alcohol, ether, oxygen, etc.) should be kept away from the laser radiation area, and protective measures should be taken!
6. Metal instruments can cause laser reflection. The operator should avoid direct exposure to these instruments, and try not to use reflective instruments!
7. Avoid wearing jewelry that can reflect laser light such as watches, necklaces, bracelets, etc. during operation!
8. Patients must be provided with strict and effective eye protection. Such as covering with gauze, eyelid, eye mask, etc. The operator applies gauze to cover the operator's eye. When washing eyeliner, you must follow our company's training method and perform eyeliner surgery after skilled operation! The use of eyelid and eye mask to protect the eyeball is convenient for surgery, and the operator should have clinical experience in ophthalmology. When using the above instruments, be sure to do a good job of disinfection. Otherwise, improper protection of the eyeball will cause great discomfort to the operator, causing corneal inflammation in mild cases, and corneal shedding in severe cases, and even blindness.
9. Except for the affected area to be treated and the target for adjusting the laser, it is strictly forbidden to irradiate other places with the laser. When moving the pistol during treatment and placing the pistol after treatment, the end exit of the pistol head must point to a safe place!
10. A laser radiation warning sign should be posted at the entrance of the laser treatment room. Unrelated personnel are prohibited from entering and leaving at will during the use of the laser!
11. The absorption of laser light by pigments of different diseased tissues is different. The choice of energy required for treatment should be from small to large.
12. It is recommended that you be equipped with a dedicated laser operation room. It is forbidden to use any reflective equipment indoors, and the room is equipped with air conditioners, cooling machines and other equipment. Laser operation should be divided into areas specially designated for operators and operators, and pre-operative precautions should be posted indoors!
13. Note: A large spot corresponds to a smaller energy density, and a small spot corresponds to a large energy density!
Energy density = energy size / spot area.
eye protection
1. Operators in the laser operating area must wear protective glasses! Strict eye protection must be provided to the operator!
2. The operator in the operation area should wear special laser protective goggles, and the suitable wavelength is 200-1080nm!
3. The laser safety goggles cannot completely protect the direct laser or the laser reflected by glass, mirror and smooth metal surface. Therefore, it is strictly forbidden to wear goggles to look directly at the above-mentioned direct laser and reflected light.
4. Covering with gauze, wearing protective goggles, eyelid shielding, etc. are effective to protect the eyes of the operator!
5. It is better to use wet gauze to protect the eyes, but the treatment part must be kept absolutely dry!
6. Please turn off the instrument when debugging the laser or wiping the laser lens!
1.USA Coherent brand laser emitter, stable light.
2.Safety treatment. Stable performance. long usage life.
3.High efficiency. Absorption of melanin to achieve the effect of painless hair removal effectively.
4.Pain free. Sapphire touch cooling system can make sure that treatment more safe and no hurt to skin.
5.Fast hair removal result. The big spot size prompt the treatment speed.
6.Permanent hair removal. Applicable to all skin color, excellent result.
Laser type |
Semiconductor laser(755nm+808nm+1064nm) |
Screen Size |
10.4 Inch |
Laser bar |
600W/800W/1000W |
Energy density |
1-50J/cm2 50*2.4=120J(Deviations+2%) |
Pulse width range |
1-20ms |
Spot size |
12*20mm |
Frequency |
1-10HZ |
Cooling System |
Semiconductor+built-in water+Air Cooling triple cooling systems |
Fuse specification |
05x25 10A |
Input Power |
2000W |
Power |
AC220V+10% 10A 50HZ, 110vt10% 10A 60HZ |
Package size |
60*47*62CM |
Gross weight |
36kg |