Quick Details
-
Brand Name:
-
MSL
-
Model Number:
-
MSLUS06
-
Rated supply voltage:
-
A.C.220V (The grid power source)
-
Voltage fluctuation range:
-
A.C. 190-240V
-
Carrier frequency:
-
55.5KHz±1%
-
Maximum input current:
-
3.15A
-
Input power:
-
690V
-
Maximum amplitude:
-
100um±1%
-
Maximum output current:
-
380mA±1%
-
Fuse:
-
T3.15A,L250VP
-
Case size:
-
360*330*160mm
-
The error range of amplitude value:
-
1%
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Free spare parts
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
MSL
-
Model Number:
-
MSLUS06
-
Rated supply voltage:
-
A.C.220V (The grid power source)
-
Voltage fluctuation range:
-
A.C. 190-240V
-
Carrier frequency:
-
55.5KHz±1%
-
Maximum input current:
-
3.15A
-
Input power:
-
690V
-
Maximum amplitude:
-
100um±1%
-
Maximum output current:
-
380mA±1%
-
Fuse:
-
T3.15A,L250VP
-
Case size:
-
360*330*160mm
-
The error range of amplitude value:
-
1%
Product Description
Clinical technical requirements
I.The output mode:
The system has two output modes :MIN mode and MAX mode.
The coagulation mode can be adjusted form 1 to 5 gears, and the cut mode is fixed to 5 gears.
1. II. Adopting constant current tissue adaptive control technology , tracking tissue changes and outputting constant current to
ensure constant amplitude.
III. All blood vessels within 3mm can be safely closed during operation,and the limit can reach 5mm.
1. IV. Output control :with foot switch and manual switch control function.
2. V. Transducer detection function :detect the operating parameters (static capacitance, impedance, resonant frequency ) of the
transducer to ensure high efficiency , stable and safe output of the transducer.
3. VI. Full touch screen control , activate and automatically clear the error prompt.
VII.Intelligent monitoring function of the system:
(I) Monitoring the opening and closing of the tool bit jaws during the test.
(II)Detecting the connection reliability between the transducer and the cutter head.
(III)Detecting jaw pressure overload alarm.
(IV)Detecting the service life of the transducer.
(V)Test the performance of manual control and foot control switches.
(VI)Detect the generator temperature and give an alarm.
VIII. Key hardware structure:
(I)Adopting quad-core CPU control,which is responsible for alarm and display,phase tracking,organization adaptive control and
whole system operation.
(II)The hardware current closed-loop control is adopted,and the output amplitude is stable.
The system has two output modes :MIN mode and MAX mode.
The coagulation mode can be adjusted form 1 to 5 gears, and the cut mode is fixed to 5 gears.
1. II. Adopting constant current tissue adaptive control technology , tracking tissue changes and outputting constant current to
ensure constant amplitude.
III. All blood vessels within 3mm can be safely closed during operation,and the limit can reach 5mm.
1. IV. Output control :with foot switch and manual switch control function.
2. V. Transducer detection function :detect the operating parameters (static capacitance, impedance, resonant frequency ) of the
transducer to ensure high efficiency , stable and safe output of the transducer.
3. VI. Full touch screen control , activate and automatically clear the error prompt.
VII.Intelligent monitoring function of the system:
(I) Monitoring the opening and closing of the tool bit jaws during the test.
(II)Detecting the connection reliability between the transducer and the cutter head.
(III)Detecting jaw pressure overload alarm.
(IV)Detecting the service life of the transducer.
(V)Test the performance of manual control and foot control switches.
(VI)Detect the generator temperature and give an alarm.
VIII. Key hardware structure:
(I)Adopting quad-core CPU control,which is responsible for alarm and display,phase tracking,organization adaptive control and
whole system operation.
(II)The hardware current closed-loop control is adopted,and the output amplitude is stable.
Specification
item
|
value
|
Rated supply voltage
|
A.C.220V (The grid power source)
|
Voltage fluctuation range
|
A.C. 190-240V
|
Carrier frequency
|
55.5KHz±1%
|
Maximum input current
|
3.15A
|
Input power
|
690V
|
Maximum amplitude
|
100um±1%
|
Maximum output current
|
380mA±1%
|
Fuse
|
T3.15A,L250VP
|
Case size
|
360*330*160mm
|
The error range of amplitude value
|
1%
|