- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
HTT-30KVA
-
Weight:
-
80KG
-
Product name:
-
Online UPS Systems
-
Battery Type:
-
Lead-acid Maintenance-free Battery
-
Wave Form:
-
Pure Sinewave
-
Transfer time:
-
0ms
-
Certification:
-
CE
-
Efficiency:
-
>96%
-
Display:
-
LCD+LED Display
-
Dimensions:
-
420*750*880mm
-
Frequency Range:
-
35-70 HZ
-
Voltage range:
-
291-492
Quick Details
-
Warranty:
-
1year
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
BAYKEE
-
Model Number:
-
HTT-30KVA
-
Weight:
-
80KG
-
Product name:
-
Online UPS Systems
-
Battery Type:
-
Lead-acid Maintenance-free Battery
-
Wave Form:
-
Pure Sinewave
-
Transfer time:
-
0ms
-
Certification:
-
CE
-
Efficiency:
-
>96%
-
Display:
-
LCD+LED Display
-
Dimensions:
-
420*750*880mm
-
Frequency Range:
-
35-70 HZ
-
Voltage range:
-
291-492
Product Description
H
TT Series Single phase, Three phase high frequency online UPS
Main Features
1. DSP control, double conversion true online three phase input three phase output UPS
2. Through filter, PFC, and convert AC into DC, and then DC is converted into AC output by inverter.
3. Adopt similar to modular design; integrate the every phase power parts into the same PCB boards. But not whole module design.
4. Advanced adaptive feed forward offset control, low harmonic distortion
5. THDi<1%
6. Input power factor: 0.99@10% load
7. Efficiency: 95%
8. Compact design, high space use
9. In front of the operation design, ease of maintenance and replacement
10. Can set input/output single phase/three phase
11. Compatible with various types of loads
12. Can 4pcs in parallel
13. With kinds of communication interface
14. More than 60% recyclable material
15. Display the remaining discharge time
16. Digital LCD display, beautiful and easy to operate
17. Compatible with many languages
18. This series max. power is 200kVA



Specification
HTT Series Specification
Model
|
|
HTT-10kS
|
HTT-10kH
|
HTT-15kS
|
HTT-15kH
|
HTT-20kS
|
HTT-20kH
|
|||||||
Capacity
|
|
10kVA / 8kW
|
|
15kVA / 12kW
|
|
20kVA / 16kW
|
|
|||||||
Input
|
|
|
|
|
|
|
|
|||||||
Voltage range
|
Low line loss
|
110 VAC(Ph-N) ± 3 % at 50% load
|
|
|
|
|
|
|||||||
|
|
176 VAC(Ph-N) ± 3 % at 100% load
|
|
|
|
|
|
|||||||
|
Low line comeback
|
Low line loss voltage + 10V
|
|
|
|
|
|
|||||||
|
High line loss
|
300 VAC(L-N) ± 3 % at 50% load
|
|
|
|
|
|
|||||||
|
|
276 VAC(L-N) ± 3 % at 100% load
|
|
|
|
|
|
|||||||
|
High line comeback
|
High line loss voltage - 10V
|
|
|
|
|
|
|||||||
Frequency range
|
|
46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system
|
|
|
|
|
|
|||||||
Phase
|
|
Three phase with neutral
|
|
|
|
|
|
|||||||
Power factor
|
|
≧ 0.99 at 100% load
|
|
|
|
|
|
|||||||
Output
|
|
|
|
|
|
|
|
|||||||
Phase
|
|
Three phase with neutral
|
|
|
|
|
|
|||||||
Output voltage
|
|
208/220/230/240VAC(Ph-N)
|
|
|
|
|
|
|||||||
AC voltage regulation
|
|
± 1%
|
|
|
|
|
|
|||||||
Frequency range (Synchronized range)
|
|
46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system
|
|
|
|
|
|
|||||||
Frequency range (Batty. mode)
|
|
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
|
|
|
|
|
|
|||||||
|
AC mode
|
100%~110%: 10min
|
|
|
|
|
|
|||||||
|
|
110%~130%: 1min
|
|
|
|
|
|
|||||||
|
|
>130% : 1sec
|
|
|
|
|
|
|||||||
|
Battery mode
|
100%~110%: 30sec
|
|
|
|
|
|
|||||||
|
|
110%~130%: 10sec
|
|
|
|
|
|
|||||||
|
|
>130% : 1sec
|
|
|
|
|
|
|||||||
Current crest ratio
|
|
3:1 max
|
|
|
|
|
|
|||||||
Harmonic distortion
|
|
≦ 2 % @ 100%linear load; ≦ 5 % @ 100% Non-linear load
|
|
|
|
|
|
|||||||
Transfer time
|
Line To Battery
|
0 ms
|
|
|
|
|
|
|||||||
|
Inverter To Bypass
|
0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
|
|
|
|
|
|
|||||||
|
Inverter To ECO
|
<10 ms
|
|
|
|
|
|
|||||||
Efficiency
|
|
|
|
|
|
|
|
|||||||
AC mode
|
|
> 89%
|
|
>89%
|
|
>89%
|
|
|||||||
Battery mode
|
|
> 86%
|
|
>88%
|
|
>87%
|
|
|||||||
Battery
|
|
|
|
|
|
|
|
|||||||
|
Type
|
12 V / 9 Ah
|
|
12 V / 9 Ah
|
|
12 V / 9 Ah
|
|
|||||||
|
Numbers
|
20(18-20 adjustable)
|
|
2 x 20(18-20
|
|
2 x 20(18-20
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||
|
Recharge time
|
9 hours recover to 90% capacity
|
|
|
|
|
|
|||||||
|
Charging current
|
1.0 A ± 10% (max.)
|
|
2.0 A ± 10% (max.)
|
|
2.0 A ± 10% (max.)
|
|
|||||||
|
Charging voltage
|
273 VDC ± 1%
|
|
|
|
|
|
|||||||
|
Type
|
Depending on applications
|
|
|
|
|
|
|||||||
|
Numbers
|
18 - 20
|
|
|
|
|
|
|||||||
|
Charging current
|
4.0 A ± 10% (max.)
|
|
4.0 A ± 10% (max.)
|
|
4.0 A ± 10% (max.)
|
|
|||||||
|
Charging voltage
|
273 VDC ± 1%
|
|
|
|
|
|
|||||||
Physical
|
|
|
|
|
|
|
|
|||||||
|
Dimension, D X W X H mm
|
815X250 X826
|
592X250 X826
|
815X250 X826
|
592X250 X826
|
815X250 X826
|
592X250 X826
|
|||||||
Outline
|
Net weight (kg)
|
109
|
38
|
164
|
40
|
164
|
40
|
|||||||
|
Dimension, D X W X H mm
|
920X380 X1025
|
700X385 X1071
|
920X380 X1025
|
700X385 X1071
|
920X380 X1025
|
700X385 X1071
|
|||||||
Packaging
|
Net weight (kg)
|
127
|
45
|
182
|
47
|
182
|
47
|
|||||||
Environment
|
|
|
|
|
|
|
|
|||||||
Operation temperature
|
|
0 ~ 40°C (the battery life will down when > 25°C)
|
|
|
|
|
|
|||||||
Operation humidity
|
|
<95 % and non-condensing
|
|
|
|
|
|
|||||||
Operation altitude**
|
|
<1000m
|
|
|
|
|
|
|||||||
Acoustic noise level
|
|
Less than 60dB @ 1 meter
|
|
Less than 65dB @ 1 meter
|
|
|
|
|||||||
Management
|
|
|
|
|
|
|
|
|||||||
Smart RS-232 or USB
|
|
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux and MAC
|
|
|
|
|
|
|||||||
Optional SNMP
|
|
Power management from SNMP manager and web browser
|
|
|
|
|
|
Model
|
HTT-30kVA
|
HTT-40kVA
|
HTT-50kVA
|
HTT-60kVA
|
HTT-80kVA
|
HTT-100kVA
|
HTT-120kVA
|
|||||||
Capacity
|
30kVA/30kW
|
40kVA/36kW
|
50kVA/45kW
|
60kVA/60kW
|
80kVA/72kW
|
100kVA/90kW
|
120kVA/108kW
|
|||||||
Mains input(AC)
|
|
|
|
|
|
|
|
|||||||
Phase
|
3 phase +N+PE
|
|
|
|
|
|
|
|||||||
Voltage range
|
291~492 V(line-line) full load; 200V~291V linearly decrease
|
|
|
|
|
|
|
|||||||
Frequency range
|
35Hz~70Hz
|
|
|
|
|
|
|
|||||||
THDi
|
<3% (full linear load)
|
|
|
|
|
|
|
|||||||
Power factor
|
0.995
|
|
|
|
|
|
|
|||||||
Bypass range
|
-10%~10% (can customized -10%~-30%, +10%~+20%)
|
|
|
|
|
|
|
|||||||
Battery
|
|
|
|
|
|
|
|
|||||||
Connection type
|
Positive series and negative series battery
|
|
|
|
|
|
|
|||||||
Rated voltage
|
+180Vdc~ +300Vdc,-180Vdc~ -300Vdc
|
|
|
|
|
|
|
|||||||
Battery number
|
30-50pcs/set (even number optional)
|
|
|
|
|
|
|
|||||||
Charging current
|
can be set according to battery capacity
|
|
|
|
|
|
|
|||||||
Output(inverter)
|
|
|
|
|
|
|
|
|||||||
Output voltage
|
380VAC 3 phase+N+PE
|
|
|
|
|
|
|
|||||||
Voltage regulation
|
<±1%
|
|
|
|
|
|
|
|||||||
Phase lock range
|
50Hz/60Hz±5Hz(self frequency 50Hz/60Hz±0.01Hz)
|
|
|
|
|
|
|
|||||||
Output frequency
|
50Hz/60Hz±0.01Hz(turn into mains frequency if phase locked)
|
|
|
|
|
|
|
|||||||
Power factor
|
1
|
0.9
|
0.9
|
1
|
0.9
|
0.9
|
0.9
|
|||||||
Crest factor
|
3:1
|
|
|
|
|
|
|
|||||||
THDu
|
THD≤2.0% (linear load), THD≤3%(non-linear load)
|
|
|
|
|
|
|
|||||||
Three phase voltage unbalance degree
|
Balance load: ≤0.5% 100% Unbalance load : ≤1%
|
|
|
|
|
|
|
|||||||
Dynamic voltage transient range
|
≤5%
|
|
|
|
|
|
|
|||||||
Transient recovery time
|
≤20ms
|
|
|
|
|
|
|
|||||||
Three phase voltage deviation
|
Mains:0.4°; Battery :0.3°
|
|
|
|
|
|
|
|||||||
Transfer time
|
Mains to battery: 0ms; Inverter to bypass: 0ms
|
|
|
|
|
|
|
|||||||
Overload capacity
|
125% for 10min: 150% for 1min; >150% for 200ms (linear load)
|
|
|
|
|
|
|
|||||||
System efficiency
|
>95%
|
|
|
|
|
|
|
|||||||
Environment indicator
|
|
|
|
|
|
|
|
|||||||
Noise
|
<65dB @100%load, cooling fan adopt intelligent speed control
|
|
|
|
|
|
|
|||||||
Display
|
Touch screen LCD+LED
|
|
|
|
|
|
|
|||||||
Interface
|
Standard: RS232, RS485, dry contacts;(SNMP card optional)
|
|
|
|
|
|
|
|||||||
Operation temperature
|
Temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C,Altitude(m): <1000, 1000m-2000m above every 100m reduce 1%
|
|
|
|
|
|
|
|||||||
IP class
|
IP30( Removable dust filter)
|
|
|
|
|
|
|
|||||||
Physical specifications
|
|
|
|
|
|
|
|
|||||||
Cabinet size (W*D*H)
|
420*750*880
|
|
|
600*800*1250
|
|
|
|
|||||||
Cabinet weight KG
|
80
|
85
|
85
|
210
|
230
|
235
|
250
|
|||||||
NOTES: Subject to change without further notice!
|
|
|
|
|
|
|
|
Model
|
HTT-150kVA
|
HTT-200kVA
|
HTT-300kVA
|
HTT-400kVA
|
HTT-500kVA
|
|||||
Capacity
|
150kVA/135kW
|
200kVA/180kW
|
300kVA/270kW
|
400kVA/360kW
|
500kVA/450kW
|
|||||
Mains input(AC)
|
|
|
|
|
|
|||||
Phase
|
3 phase +N+PE
|
|
|
|
|
|||||
Voltage range
|
291~492 V(line-line) full load; 200V~291V linearly decrease
|
|
|
|
|
|||||
Frequency range
|
35Hz~70Hz
|
|
|
|
|
|||||
THDi
|
<3% (full linear load)
|
|
|
|
|
|||||
Power factor
|
0.995
|
|
|
|
|
|||||
Bypass range
|
-10%~10% (can customized -10%~-30%, +10%~+20%)
|
|
|
|
|
|||||
Battery
|
|
|
|
|
|
|||||
Connection type
|
Positive series and negative series battery
|
|
|
|
|
|||||
Rated voltage
|
+180Vdc~ +300Vdc,-180Vdc~ -300Vdc
|
|
|
|
|
|||||
Battery number
|
30-50pcs/set (even number optional)
|
|
|
|
|
|||||
Charging current
|
can be set according to battery capacity
|
|
|
|
|
|||||
Output(inverter)
|
|
|
|
|
|
|||||
Output voltage
|
380VAC 3 phase+N+PE
|
|
|
|
|
|||||
Voltage regulation
|
<±1%
|
|
|
|
|
|||||
Phase lock range
|
50Hz/60Hz±5Hz(self frequency 50Hz/60Hz±0.01Hz)
|
|
|
|
|
|||||
Output frequency
|
50Hz/60Hz±0.01Hz(turn into mains frequency if phase locked)
|
|
|
|
|
|||||
Power factor
|
0.9
|
0.9
|
0.9
|
0.9
|
0.9
|
|||||
Crest factor
|
3:1
|
|
|
|
|
|||||
THDu
|
THD≤2.0% (linear load), THD≤3%(non-linear load)
|
|
|
|
|
|||||
Three phase voltage unbalance degree
|
Balance load: ≤0.5% 100% Unbalance load : ≤1%
|
|
|
|
|
|||||
Dynamic voltage transient range
|
≤5%
|
|
|
|
|
|||||
Transient recovery time
|
≤20ms
|
|
|
|
|
|||||
Three phase voltage deviation
|
Mains:0.4°; Battery :0.3°
|
|
|
|
|
|||||
Transfer time
|
Mains to battery: 0ms; Inverter to bypass: 0ms
|
|
|
|
|
|||||
Overload capacity
|
125% for 10min: 150% for 1min; >150% for 200ms (linear load)
|
|
|
|
|
|||||
System efficiency
|
>95%
|
|
|
|
|
|||||
Environment indicator
|
|
|
|
|
|
|||||
Noise
|
<65dB @100%load, cooling fan adopt intelligent speed control
|
|
|
|
|
|||||
Display
|
Touch screen LCD+LED
|
|
|
|
|
|||||
Interface
|
Standard: RS232, RS485, dry contacts;(SNMP card optional)
|
|
|
|
|
|||||
Operation temperature
|
Temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C,Altitude(m): <1000, 1000m-2000m above every 100m reduce 1%
|
|
|
|
|
|||||
IP class
|
IP30( Removable dust filter)
|
|
|
|
|
|||||
Physical specifications
|
|
|
|
|
|
|||||
Cabinet size (W*D*H)mm
|
600*1100*2000
|
|
600*1100*2000
|
|
1200*1100*2000
|
|||||
Cabinet weight (KG)
|
415
|
460
|
520
|
620
|
920
|
|||||
NOTES: Subject to change without further notice!
|
|
|
|
|
|
Packing & Delivery

To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Hot Searches