- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
Maya
-
Model Number:
-
MY-S015
-
Product name:
-
Traction bed lumbar cervical traction equipment for hospital
-
Lumbar traction course:
-
0~200 mm,Tolerance:±10 mm
-
Treatment time:
-
0~60 min,tolerance not more than 30 S
-
Lumbar individual cycle traction time:
-
0~90 S
-
Lumbar traction interval time:
-
0~90 S
-
Supply voltage:
-
15.220V/50Hz
-
Power input:
-
14.200VA
-
Vertical movement speed:
-
5mm/s~9mm/s
-
Traction pitch angle:
-
-10°~+30° Tolerance: ±2°
-
Traction swing angle:
-
-25°~+25°Tolerance: ±2°
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Online technical support
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Maya
-
Model Number:
-
MY-S015
-
Product name:
-
Traction bed lumbar cervical traction equipment for hospital
-
Lumbar traction course:
-
0~200 mm,Tolerance:±10 mm
-
Treatment time:
-
0~60 min,tolerance not more than 30 S
-
Lumbar individual cycle traction time:
-
0~90 S
-
Lumbar traction interval time:
-
0~90 S
-
Supply voltage:
-
15.220V/50Hz
-
Power input:
-
14.200VA
-
Vertical movement speed:
-
5mm/s~9mm/s
-
Traction pitch angle:
-
-10°~+30° Tolerance: ±2°
-
Traction swing angle:
-
-25°~+25°Tolerance: ±2°
Guangzhou Maya Medical Equipment CO.,LTD
1.More than 10 years experience
2.One-stop service
3.Overseas showroom
4.Main Products: X-ray machine , CT/MRI scan , Ultrasound Machine , Laboratory Equipment , Dental Equipment , Gynecology Equipment and so on.
MY-S015 medical physiotherapy equipment lumbar cervical traction device treatment table traction bed
Micro-computer control multifunctional lumbar vertebrae traction bed uses imported motor and microcomputer software IC as control. In clinical application can automatic vertical traction (picture 1), automatic angled traction (picture 2), automatic swing traction (picture 3). These three functions can be used alone, or in combination. While in the vertical traction, can combined with angled traction, swing traction, negative pressure traction, to overcome the disadvantages of a single action. Especially for posterior lumbar facet joint dislocation reset, disorder, thoracolumbar compression fractures (no paraplegia ), change lumbar vertebrae physiological curvatur disappear or posterior process, it has more significant effect. (when used, it can supine traction or prone traction)
Technical parameter
1. Lumbar traction course: 0~200 mm, Tolerance :±10 mm
2. Treatment time: 0~60 min,tolerance not more than 30 S
3. Lumbar individual cycle traction time: 0~90 S,tolerance not more than 30 S
4. Lumbar traction interval time : 0~90 S,tolerance not more than 30 S
5. Lumbar traction power:0~200N, Tolerance: ±10N;200~990N ,Tolerance: ±50N
6. Vertical movement speed: 5mm/s~9mm/s
7. Traction pitch angle: -10°~+30° Tolerance: ±2°
8. Traction swing angle: -25°~+25° Tolerance: ±2°
9. Maximum course of cervical traction: ≥200 mm
10. Cervical traction: 0~300 N Tolerance:±10N
11. Cervical traction speed: 5mm/s~9 mm/s
12. Cervical individual cycle traction time: 0~9min,tolerance not more than 30 S
13. Cervical traction interval time : 0~90 S,tolerance not more than 30 S
14. Power input: 200VA
15. Supply voltage:220V/50Hz