- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
5F/6F/7F/8F
-
Place of Origin:
-
Shanghai, China
-
Licence Number:
-
20061430
-
OEM&ODM Service:
-
Support
Quick Details
-
Warranty:
-
3 years
-
After-sale Service:
-
Return and Replacement
-
Brand Name:
-
INT
-
Model Number:
-
5F/6F/7F/8F
-
Place of Origin:
-
Shanghai, China
-
Licence Number:
-
20061430
-
OEM&ODM Service:
-
Support
Shanghai INT Medical Femoral Introducer Sets
[Product Structure] The product is composed of introducer sheath, dilator, guide wire, and seldinger needle. The product is made from polyethylene, polypropylene, and stainless steel.
[Product Type] 5F, 6F, 7F, 8F
[ Applicatio n Scope] The introducer set and dilator enter into the vas along guidewire to build a passage, which connects skin and vas. After the dilator pulling out, the introducer sheath is the only entrance for the vas operation. The hemostasis valve of introducer set and the silica gel film at the hub is respectively used to stop blood stream and prevent seeping blood. It could avoid hemorrhage.
[Instruction for Use]
- 1) Shave the skin, disinfect, spread the cloth and lay gauze aside.
- 2) Puncture with seldinger needle from the top of the skin with angel between 30-45 degrees until bright
- red blood gush from the hub of the seldinger needle to make sure the needle attains needed position.
- 3) Insert the guidewire across the seldinger needle until the position needed.
- 4) Hold guidewire tightly and then remove the seldinger needle.
- 5) Insert dilator into the sheath, then insert guidewire from the end of dilator, hold tightly when the dilator is approaching the skin, and rotate gently while pushing into the vessel.
- 6) Hold sheath tightly and remove guidewire and dilator.
- 7) Translate catheter across the sheath into the vessel at needed position. If necessary, fix the sheath.
- 8) A fter operating, remove the sheath and process hemostasis.
NOTE
Hold the guidewire anytime. According to the centimeter mark, adjust the insertion depth.
If widening percutaneous puncture is needed, do the operation with scalpel, its blade opposite to the guidewire.
Type I (Radial) | |||||||
Ref. NO. | Fr Size | Sheath | Dilator | Guide Wire |
Needle
(G/mm) |
||
I. D.
(mm) |
L
(mm) |
I. D.
(mm) |
L
(mm) |
O. D.
(inch) |
|||
TR01 | 5F | 1.9 | 110 | 0.68 | 168 | 0.021 | 21/45 |
TR02 | 6F | 2.1 | 110 |
Characteristic:
Type I (Radial)
1.Longer taper ensure smooth transition between sheath and dilator
2.Excellent pushability, flexibility and radiopacity
3.0.021” stainless steel guide wire, hydrophilic guide wire available upon request
Type II (Radial)
1.Longer taper ensure smooth transition between sheath and dilator
2.Excellent pushability, flexibility and radiopacity
3.Hydrophilic guide wire with cannula needle is available
4.Hydrophilic coated sheath available
Type III (Femoral)
1.Excellent pushability, flexibility and radiopacity
2.Smooth transition between sheath and dilator
3.No leakage under 80kpa
4.Hydrophilic coated sheath available
Int-Medical current
product portforlio:
Interventional:
PTCA balloon catheter, PTCA guide wires, Baloon inflation devices,
angiographic
catheters, Introducers sets, Hemostasis valve sets, High pressure Manifolds,
Pressure bandages, Dose-control syringes, Color piston specialty sringes, Introducer needles.
Orthepedic Intervention:
PVP Tool Kit,Spin Tool Kit,PKP Balloon Catheter,ECTR Disposable Kit,Bone Biopsy Drill,Bone Needle+vacuum Lock Syringe
Peripheral Intervention:
Intestinal Ballon Catheter,Vaginal Speculum
Infusion &Injection & accessories : Vacuum Lock Syringe,PC Syringe,Infusion Pump,High pressure tubings,(Anti-back)Needle Free Connector, Stopcock,Manifolds for Anesthesiology