- Product Details
- {{item.text}}
Quick Details
-
Product Series:
-
EasyPactMT
-
Circuit breaker application:
-
Distribution protection
-
Number of poles:
-
3P 4P
-
Network frequency:
-
50/60 Hz
-
Type of release:
-
Electronic
-
Trip protection function:
-
LSI
-
Type of installation:
-
Drawer type
-
Short delay current setting type:
-
9 levels adjustable
-
Short delay time setting type:
-
5 levels adjustable
-
Instantaneous protection current:
-
Adjustable
Quick Details
-
Brand Name:
-
standard
-
Place of Origin:
-
Zhejiang, China
-
Model Number:
-
Shunt release
-
Product Series:
-
EasyPactMT
-
Circuit breaker application:
-
Distribution protection
-
Number of poles:
-
3P 4P
-
Network frequency:
-
50/60 Hz
-
Type of release:
-
Electronic
-
Trip protection function:
-
LSI
-
Type of installation:
-
Drawer type
-
Short delay current setting type:
-
9 levels adjustable
-
Short delay time setting type:
-
5 levels adjustable
-
Instantaneous protection current:
-
Adjustable
![](https://cdn.bestsuppliers.com/seo_products_img/zjyiguan/ec7f18138e4e396fa9e38debfec9c440.png!/rotate/180)
![](https://cdn.bestsuppliers.com/seo_products_img/zjyiguan/270f268d57e933b9ba93bfc4bfaa7c7a.png!/rotate/180)
![](https://cdn.bestsuppliers.com/seo_products_img/zjyiguan/625a1eb8073e39a4bc7b01d6770ed1cb.png!/rotate/180)
![](https://cdn.bestsuppliers.com/seo_products_img/zjyiguan/ec29098b583831d3a32cb1ae1298801f.png!/rotate/180)
Micrologic control unit AC-additional position switch driver
S-Basic 2.0 √ 5.0 Remote operation
A-Ammeter 2.0 5.0 6.0 7.0 Remote ON/OFF MCH-Energy storage motor 220
D-Energy meter 5.0 6.0 XF-Closing coil 220
P-Power meter 5.0 6.0 7.0 MX-Shunt coil 220
H-Harmonic meter 5.0 6.0 7.0 PF-"Ready to close" contact small capacity
LR-Long time delay protection socket standard 0.4 ~ 1 Ir 6 A-240 V AC
Low setting value 0.4 ~ 0.8 Ir BPFE-electrical close button
High setting value 0.8 ~ 1 Ir Res-electrical reset option
LR off (no long delay protection) RAR-automatic reset option
AD-external power supply module V remote trip MN-undervoltage trip
BAT-battery module R-delay unit (not adjustable)
TCE-external current transformer Rr-adjustable delay unit
Used for neutral line and residual current type ground fault protection second MX
TCE-External current transformer for super large neutral wire lock
(3 P-Micrologic P / H) and residual current type ground fault protection VBP-ON/OFF button lock (transparent cover + padlock)
TCW-external current transformer for SGR type ground fault protection OFF position lock:
Rectangular transformer for leakage protection Type N (280 x 115 mm) VCPO-Padlock
Type H (470 x 160 mm) VSPO-Bracket for key lock (without lock) Profalux
PTE-External voltage measurement input 1 lock Profalux
Communication 2 Lock 1 Key Profalux
COM module ModBus body chassis 2 locks, different keys (H type) Profalux
Digipact body chassis chassis "exit" position lock:
Modbus VSPD module-key lock bracket (lock not included) Profalux
(For cabinet display module) 1 lock Profalux
Connection 2 lock 1 key Profalux
Horizontal top and bottom 2 locks, different keys Profalux
Vertical upper end and lower end optional connection/exit/test position lock
Front upper end lower end VPEC-door interlocking chassis right interlocking
Vertical connection adapter N type-fixed front, drawer type chassis left interlock
Cable crimp terminal adapter N type-fixed front, drawer type VPOC-advance and retreat interlock
Arc chute screen N type-fixed front IPA-cable type door interlock
Phase spacer fixed type, drawer type VDC-mismatch protection
Smart Controller Micrologic 2.0 / Micrologic 5.0 / Micrologic 6.0
LR-Long Delay Tuning Module
MCH-energy storage motor MCH MT 08-63H/L D/O AC200-240V
MX-shunt coil MX standard type 200-250Vac/dc
XF-closing coil XF standard type 200-250Vac/dc
Chassis MT N2/H1/H1b/H2-800/1600A 3P
CDP-door frame CDP MT 08-63 D/O
Horizontal wiring behind the upper end MT08-63H/L 800/2000A D/O 3P
Horizontal wiring behind the lower end MT08-63H/L 800/2000A D/O 3P
Phase spacer 3P D/O
AD-external power supply module AD 220Vac
BAT-battery module
4 contact additional block
Additional SDE fault trip contact
Additional low-capacity SDE fault trip contacts
CE connection position contact
CT test position contact
CD exit position contact
PF-Ready to close contact PF MT 08-63 5A-240Vac
BPFE-electric closing button BPFE MT 08-63
Remote electrical reset option after Res fault disconnection Res 220-240Vac
2ndMX-Second shunt release 2ndMX 200-250Vac/dc
MN-under voltage release MN 200-250Vac/dc
Rr/R-adjustable/non-adjustable undervoltage delay unit Rr 200-250Vac/dc
VBP-button locking device VBP MT 08-63
OFF position lock VCPO
OFF position lock bracket MT 08-63
Key lock interlock, three locks and two keys, bracket N containing the lock
CB-Secondary wiring terminal cover CB 800/4000A 3P
VSPD-Exit position lock [Need to purchase lock bracket separately] VSPD Profalux 1 lock
VSPD Exit Position Lock Bracket Profalux Lock Bracket-Exit Position Lock MT 08-63H/L
VPOC-swing-in interlock [forward and retreat] VPOC MT 08-63H/L
VPEC-door interlock VPECD MT 08-63
VDC-breaker adaptation protection
The DAE-switch is moved out and the spring automatically releases energy
VIVC front baffle position indicator and locking device VIVC 800/4000A 3P
IBPO-Rocking-in interlock between rocker and OFF button
Bezel locking block [2 spares] Spare safety bezel locking block 800/4000A
CP-transparent cover CP MT 08-63
OP-door frame partition board OP MT 08-63
CDM-Mechanical Operation Counter CDM MT 08-63
Connecting rod interlock MT 08-63
Rope interlock
Cable type door interlock MT 08-63
1. Top fixed
2. Bottom fixed
3. Protective cover
4. Cover opening point
5. The lead seal of the protective cover is fixed
6. Long delay tuning module
7. Long time delay tuning module fixing screw
8. Circuit breaker connection port
9. Far-infrared link communication excuse
10. External link terminal
11. Battery box
12. Digital display
13. Three-phase column display and ammeter
14. Long delay current setting
15. Long delay trip delay
16.Short time delay trip
17. Short delay trip delay
18. Instantaneous trip ISD
19. Instantaneous trip LI
20. Ground fault trip
21. Ground fault trip delay
22. Leakage trip
22. Leakage trip
23. Leakage trip delay
24. LED indicates long delay trip
25. LED indicates short delay trip
26. LED indicates ground fault or leakage trip
27. LED indicates protection trip
28. LED indicates overload
29. Switch menu button
30. Menu content display button
31. Quick browse navigation buttons
our service
Product advantages
1 high quality
2 Competitive price
3 secure payment
4 fast delivery
5 Always trustworthy
6 Experienced
7
Integrity management, consistent
product information
1 Price: source goods, low profit
2
Guarantee: You can sign a credit guarantee order and I will bear the cost. He will guarantee the security of your payment.
3 Payment methods: online payment, bank transfer, Western Union, credit card, etc. We provide high-quality customers with flexible payment terms. Offshore payment
4 Shipping method: You can choose your preferred shipping method for the goods to ensure the safe and smooth arrival of the goods
Operating products
1 Schneider. ABB, Siemens brand industrial control products
2 OEM of similar industrial control products made in China
3 Complete sets of electrical equipment made in China: such as power distribution cabinets, etc.
4 Chinese-made tea, such as West Lake Longjing, tea ceremony source tea, etc.
5 China made perfume bottle essential oil bottle
6 Air source equipment made in China, such as refrigeration dryers, suction dryers, etc.
Hot Searches