The blood coagulation analyzer adopts the principle of optical colorimetry for detection. After the reagent is mixed with the plasma, fibrinogen is converted into fibrin and coagulated, which leads to the change of the optical density of the test specimen, and the instrument detects the coagulation end point.
- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
BK-CA04
-
Place of Origin:
-
Shandong, China
-
Product name:
-
Blood Coagulation Analyzer
-
Model:
-
BK-CA04
-
Test Principle:
-
Optical Colorimetry
-
Test Channel:
-
4 (can test different projects at the same time)
-
Wavelength:
-
470nm
-
Sample Incubation Position:
-
24
-
Reagent Incubation Position:
-
6
-
Detection Position Temperature:
-
37.0±1.0°C
-
Incubation Time:
-
1-999s
-
Sample Volume:
-
20μl~40μl
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Online technical support
-
Brand Name:
-
BIOBASE
-
Model Number:
-
BK-CA04
-
Place of Origin:
-
Shandong, China
-
Product name:
-
Blood Coagulation Analyzer
-
Model:
-
BK-CA04
-
Test Principle:
-
Optical Colorimetry
-
Test Channel:
-
4 (can test different projects at the same time)
-
Wavelength:
-
470nm
-
Sample Incubation Position:
-
24
-
Reagent Incubation Position:
-
6
-
Detection Position Temperature:
-
37.0±1.0°C
-
Incubation Time:
-
1-999s
-
Sample Volume:
-
20μl~40μl
Product Description
The blood coagulation analyzer adopts the principle of optical colorimetry for detection. After the reagent is mixed with the plasma, fibrinogen is converted into fibrin and coagulated, which leads to the change of the optical density of the test specimen, and the instrument detects the coagulation end point.
Detailed Images
Specification
Model
|
BK-CA02
|
BK-CA04
|
|
Test Principle
|
Optical Colorimetry
|
|
|
Test Items
|
PT, APTT, TT, FIB
|
|
|
Test Channel
|
2 (can test different projects at the same time)
|
4 (can test different projects at the same time)
|
|
Wavelength
|
470nm
|
|
|
Detection Time
|
Normal sample detection time is 20 to 40 seconds, and can be set arbitrarily from 20 to 99 seconds
|
|
|
Sample Incubation Position
|
12
|
24
|
|
Reagent Incubation Position
|
5
|
6
|
|
Detection Position Temperature
|
37.0±1.0°C
|
|
|
Incubation Position Temperature
|
37.0±1.0°C
|
|
|
Incubation Time
|
1-999s
|
|
|
Reaction Time
|
1-99s
|
|
|
Reagent Dosage
|
Minimum dosage 20μl
|
|
|
Sample Volume
|
20μl~40μl
|
|
|
Display
|
5-inch high-definition color touch screen
|
|
|
Storage
|
20,000 results storage, automatically save measurement data when power off
|
|
|
Communication Interface
|
RS232 serial interface, support LIS system
|
|
|
Printer
|
Built-in thermal printer
|
|
|
Power Supply
|
AC100~240V, 50/60Hz
|
|
|
Consumption
|
70VA
|
|
|
Ambient Temperature
|
10℃~30℃
|
|
|
Relative Humidity
|
≤80%
|
|
|
Atmospheric Pressure
|
86kPa~106kPa
|
|
|
External Size (W* D*H)
|
360*210*120mm
|
390*250*135mm
|
|
Net Weight
|
3.5kg
|
4.96kg
|
|
Package Size (W* D*H)
|
376*246*316mm
|
445*305*265mm
|
|
Gross Weight
|
5Kg
|
7kg
|
Hot Searches