- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
programing time switch
-
Max. Current:
-
10A
-
Relay:
-
1CH/2CH
-
Working voltage:
-
5/12/24V
-
Output power:
-
10A DC/AC load
-
Time range:
-
0.01s to 9990minutes adjust
-
Signal:
-
Switch or High Low Level
-
Modes:
-
32 modes
-
Application:
-
Motors Led Light Water pump
-
Certification:
-
other
Quick Details
-
Max. Voltage:
-
24V
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Taidacent
-
Model Number:
-
programing time switch
-
Max. Current:
-
10A
-
Relay:
-
1CH/2CH
-
Working voltage:
-
5/12/24V
-
Output power:
-
10A DC/AC load
-
Time range:
-
0.01s to 9990minutes adjust
-
Signal:
-
Switch or High Low Level
-
Modes:
-
32 modes
-
Application:
-
Motors Led Light Water pump
-
Certification:
-
other
Taidacent DC 5V 12V 24V 10A Adjustable Timer Relay Switch Digital Display Time Replay Trigger Pulse Cycle Timer Delay Switch
Product Description
1 channel: 32/
2 channels: 52 kinds of default common functions, which can realize product jogging, self-locking, delay, timing cycle control, etc. (for details, please refer to the manual of the data package)
Specification
item
|
value
|
Max. Current
|
10A
|
Max. Voltage
|
24V
|
Relay
|
1CH/2CH
|
Working voltage
|
5/12/24V
|
Output power
|
10A DC/AC load
|
Time range
|
0.01s to 9990minutes adjust
|
Signal
|
Switch or High Low Level
|
Modes
|
32 modes
|
Application
|
Motors Led Light Water pump
|
1CH Port connection instructions:
DC+ input DC power positive pole
DC-input DC power supply negative pole
IN+ signal input terminal positive
IN-signal input terminal negative pole
NO relay normally open interface, when the relay is closed, it is shorted with COM, and when it is not closed, it is suspended;
COM relay public port interface
NC relay normally closed terminal interface, when the relay is not pulled in, it is shorted with COM, and when it is pulled in, it is suspended
2CH Port connection instructions
VIN+ input DC power positive pole
GND input DC power negative pole
IN1+ The positive pole of the first signal input terminal
IN1- the positive pole of the first signal input terminal
IN2+ The positive pole of the second signal input terminal
IN2- The negative pole of the second signal input terminal
NO1 Relay 1 normally open port, when relay 1 is closed, it is shorted with COM1, and when it is not closed, it is suspended;
COM1 Relay 1 common terminal interface
NC1 Relay 1 normally closed terminal interface, when relay 1 is not pulled in, it is shorted with COM1, and when it is pulled in, it is suspended;
NO2 Relay 2 normally open port, when relay 2 is closed, it is shorted with COM2, and when it is not closed, it is suspended;
COM2 Relay 2 common terminal interface
NC2 Relay 2 normally closed terminal interface, when relay 2 is not pulled in, it is shorted with COM2, and when it is pulled in, it is suspended;
Remarks
1. Between NC and COM and between NO and COM are only equivalent to a switch without voltage output
2. The power supply voltage should be strictly in accordance with the purchased relay version
3. Trigger signal: 5~24V, low level is 0
Packing & Delivery