Products
piezoelectric transducer for beauty ultherapy machine HNB-4P1-4325 in stock cavitition head
piezoelectric transducer for beauty ultherapy machine HNB-4P1-4325 in stock cavitition head
piezoelectric transducer for beauty ultherapy machine HNB-4P1-4325 in stock cavitition head
piezoelectric transducer for beauty ultherapy machine HNB-4P1-4325 in stock cavitition head

piezoelectric transducer for beauty ultherapy machine HNB-4P1-4325 in stock cavitition head

FOB Reference Price: Get Latest Price
≥200 Pieces
US $10
≥500 Pieces
US $9.5
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Brand Name:
HAINERTEC
Frequency:
1mhz, 3mhz

Quick Details

Usage:
VIBRATION SENSOR
Model Number:
HNB-4P1-4325
Place of Origin:
Jiangsu, China
Brand Name:
HAINERTEC
Frequency:
1mhz, 3mhz
Product Description
Support for custom

Technical parameters of ultrasonic focusing transducer for medical and beauty.
Model
Frequency Ft(±10%)
Capacitance (pF)
Size OD-H (mm)
Focal length
Power (W)
HNB-4F250-D75-SR40
250KHz
8000±10%
115*60
20
250W
HNB-4F250-D66-SR36
250KHz
11000±10%
90*45
15
150W
HNB-4F4000-D20-SR20
4MHz
8500±10%
22*10/11
4.5
35W
Note : We can provide different type driving circuit with 24-48 VDC or 110-220VAC input voltage, and accept R&D and customization
Principle : Focusing on ultrasound waves on a small area of the body produces high level of sound and heat. For human tissues, such as fat cells, the high temperature above 60 can be generated instantly, and coagulation necrosis can be generated in a very shor time, so as to achieve the goal of thermal ablation.
Technical paramaters of ultrasonic transdcuers for beauty fat-burning
Model
Frequency (KHz)
Capacitance (pF)
Impedance (Ω)
Size OD*H (mm)
Cap OD (mm)
HNB-4AH-2560
60±1.0
2300±10%
≤35Ω
30*35
38
HNB-4AH-3050
53±1.0
3200±10%
≤35Ω
38*40
48
HNB-4SS-3540
40±1.0
4400±10%
≤25Ω
35*55
38
HNB-4SS-3840
40±1.0
5400±10%
≤25Ω
40*58
50/62/72
HNB-4SS-3528
28±0.8
4400±10%
≤25Ω
45*79
50/62/72
HNB-4SS-3833
33±1.0
5400±10%
≤25Ω
45*61
50/62/72
Note: We can provide different type driving circuit with 24-48 VDC or 110-220VAC input voltage, and accept R&D and customization.
Principle: The high frequency ultrasonic vibration produces positive and negative pressure. It pulls away low-density adipose tissue that is high in water content, which caused the cells inside and outside implosion of microvoid, the result is that the increased of the molecular motion of high-energy molecules cause cells to break. It  has the effect of melting fat, disappear fat, mainly used in the abdomen, buttocks and legs and so on.

Technical parameters of ultrasonic transducre for face-lift.

Model
Frequency
Capacitance (pF)
Impedance (Ω)
Size (mm)
Power (W)
Structure
Notes
HNB-4P1-2316
1MHz±15%
950
≤100Ω
23*14
15W
The patch type
Round head
HNB-4P1-4325
1MHz±15%
2300
≤80Ω
43*14
20W
The patch type
Round head
HNB-4S1-3920
1MHz±15%
1480
≤80Ω
39*17.50
18W
The patch type
Circular head
HNB-4E1-4428
1MHz±15%
2300
≤80Ω
44*38.50
25W
The patch type
Cone head
HNB-4P3-4325
3MHz±15%
6900
≤80Ω
43*14
15W
The patch type
Round head
HNB-4P3-6545
3MHz±15%
20000
≤80Ω
65*11
30W
The patch type
Round head
HNB-4P5-6550
500Khz±15%
4200
≤50Ω
65*11
40W
The patch type

Principle: Similar to the priciple of fat blasting, high-frequency ultrasonic vibration causes the cavitation and implosion of low-density fat with high water content in facial tissue, and high-energy molecules cause the rupture of the whole cell, which plays the role of fat melting and lipid elimination. Because facial nerve cells are sensitive, generally higher frequencies are selected, such as above 1MHz.
Technical parameters of ultrasonic transducer for skin cleaning, make up removing, medicane guiding and atomizing.
Model
Frequency (KHz)
Capacitance (pF)
Impedance (Ω)
Size OD*H (mm)
Power (W)
Notes
HNB-4SP5-4225
500±15%
1100
≤40Ω
42*12
30W
fat-burning and dedicine guiding
HNB-4PZ-4225
1000±15%
2300
≤80Ω
42*12
20W
face lifting and medicine guiding
HNB-4P3-4225
3000±15%
6900
≤80Ω
42*12
15W
face lifting and medicine guiding
HNB-4SS-2080
80±5%
1950
≤100Ω
40*32
15W
skin cleaning and medicine guiding
HNB-4SE-2030
30±5%
1950
≤35Ω
24*83
20W
skin cleaning and medicine guiding
HNB-4SE-1540
40±5%
1650
≤45Ω
19.2*65
12W
skin cleaning and medicine guiding
HNB-4SE-1550
50±15%
1650
≤40Ω
19.2*57
12W
skin cleaning and medicine guiding
HNB-4L6-2825
25±15%
42±10%
≤100Ω
37*145
60W

HNB-4L2-2830
30±15%
14±10%
≤100Ω
37*38
20W

Note: We can provide different type driving circuit with 24-48 VDC or 110-220VAC input voltage, and accept R&D and customization.
Priciple: The cavitation effect of ultrasound in liquid has the functions of cleaning, melting fat and drug guiding. It play the functions of skin cleaning, removing fat, removing makeup, and promoting permeability. At yhe same time, the high-frequenct vibration products the massage function, it also promoted the metabolism and the activation skin cell function.
Technical parameters of ultrasonic spraying transducers for atomizing
Model
Frequency (KHz)
Power (W)
Size OD50 (um)
Max Flow (ml/min)
Structure
Notes
HNN-4SE-13100
100.0±10%
18
30±10%
10
Through the hole
Jet Peel 2
HNN-4P1-25100
1670±10%
28
8±10%
5
The patch type
Jet Peel 2
HNN-4P1-20100
2500±10%
20
3±10%
3
The patch type
Jet Peel 2
Note: We can provide different type driving circuit with 24-48 VDC or 110-220VAC input voltage, and accept R&D and customization.
Principle: Ultrasonic atomization micron particles, combined with pulse hyperbaric oxygen technology, drug essence can be introduced into the dermis, the dose is precise and controllable, for the second generation of water oxygen meter.
Technical paramaters of ultrasonic transducers for health massage.
Model
Frequency (KHz)
Capacitance (pF)
Impedance (Ω)
Size OD*H (mm)
Power (W)
Notes
HNB-8AS-2535
35±1.5
1700±10%
≤35Ω
25*150
50W
Energy-gathering
HNB-8AE-2540
40±1.5
1300±10%
≤50Ω
28*72
50W
Energy-gathering
HNB-8AS-1550
50±1.5
1650±10%
≤20Ω
18*58
15W
Energy-gathering
Note: We can provide different type driving circuit with 24-48 VDC or 110-220VAC input voltage, and accept R&D and customization.
Principle: When the high-frequency vibration produced by ultrasonic wave ACTS on human body, several effects(mechanical effect, warm effect and physical and chemical effect) play a role in tissue massage, energy absorption, drug penetration, blood circulation and blood stasis, anti-inflammatory and analgesic effects.
Supporting Euipment Parameters
Technical parameters of ultrasonic drive circuit.
Model
Frequency (KHz)
Power (W)
Size L*W*H (mm)
Related functions
Encapsulation
HNE-FP-SS
20~200
≤200
150*108*36
Seperate excitation and sweeping frequency, small signal remote control.
Over temperature over current protection, adjustable
power.
circuit board
HNE-FP-SP
20~200
≤200
150*108*36
Seperate excitation, phase lock, small signal remote control.
Over temperature over current protection, adjustable power.
Power Box
HNH-FP-SS
20~200
≤200
215*114*51
Seperate excitation and sweeping frequency, small signal remote control.
Over temperature over current protection, adjustable
power.
Power Box
HNH-FP-SP
20~200
≤200
215*114*51
Seperate excitation, phase lock, small signal remote control.
Over temperature over current protection, adjustable power.
Power Box
HNH-FP-S
500~1000
≤150
203*147*61
Seperate excitation, small signal remote control.
Over temperature over current protection, adjustable power.
Power Box
HNH-FP-S
500~1000
≤200
110*80*36
Seperate excitation, small signal remote control.
Over temperature over current protection, adjustable power.
Power Box
HNH-FP-A
500~1000
≤20
110*80*36
Auti excitation, 24VDC direct power supply.
Power Box
Note: Model HNE-FP-SS( F stands frequency, P stands power).
APP
Post My RFQ
WhatsApp
+86-17326049340