- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
AISO/OEM
-
Model Number:
-
ASQ-1250/4P
-
Rated Current:
-
1250A
-
Frame current:
-
1250
-
Product name:
-
ATS Switch
-
Rated Voltage:
-
400V
-
Packaging:
-
Export Wooden Case Packing
-
Sample:
-
Accept
-
Port:
-
Ningbo/Shanghai
-
Gurantee period:
-
18 Months
-
Certificate:
-
ISO9001
-
Rated frequency:
-
50/60Hz
-
Product Keywords:
-
Dual Power Isolation Switch
Quick Details
-
Type:
-
PC
-
Number of Pole:
-
4
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
AISO/OEM
-
Model Number:
-
ASQ-1250/4P
-
Rated Current:
-
1250A
-
Frame current:
-
1250
-
Product name:
-
ATS Switch
-
Rated Voltage:
-
400V
-
Packaging:
-
Export Wooden Case Packing
-
Sample:
-
Accept
-
Port:
-
Ningbo/Shanghai
-
Gurantee period:
-
18 Months
-
Certificate:
-
ISO9001
-
Rated frequency:
-
50/60Hz
-
Product Keywords:
-
Dual Power Isolation Switch
ATS Switch Switch auto transfer switch
Overview ATS Switch / generator automatic transfer switch / auto transfer switch
This generator automatic transfer switch/ auto transfer switch is suitable for the double-circuit power supply system of AC50/60Hz, rated voltage below 690V and rated current below 4000A, to realize automatic or manual transfer between normal power(N) and standby power(R), (Main and standby power supply can be a grid, starting generator, battery, main and standby power supply is defined by the users) then to get an unmanned transformer station for dual-power users. The ATS Switch is applicable to the provisions of the state for class or a class load user, where power failure is impermissible such as high-rise building, post and telecommunication, coal ship, industrial assembly line, medical, military facilities, airports, fire protection, metallurgy, chemical industry, textile, petroleum and etc.
Normal working conditions ATS Switch / generator automatic transfer switch / auto transfer switch
1, The air temperature is -25℃~+40℃, the average value within 24hours should not be over 35 ℃.
2, The relative humidity should not exceed 50% at max temperature +40℃, the higher relative humidity is permissible at lower temperature for instance, 90% at +20℃, but the condensation will be produced due to temperature change, which should be considered.
3, The altitude of mounting place should not exceed 2000m.
4, Classification: IV; Inclination is not more than ±23℃.
5, Pollution grade: 3
6, If beyond above mentioned conditions, users should negotiate with the manufacturer. If the product is used for sea, petroleum and nuclear power station, the technical agreement shall be sighed separately.
Model / Item | ASQ-63A | ASQ-125A | ASQ-250A | ASQ-630A | ASQ-800A | ASQ-1250A | ASQ-1600A | ASQ-2000A | ASQ-2500A | ASQ-3150A | ASQ-4000A |
Usage category | AC-33iB | ||||||||||
Rated working voltage(Ue) | AC400V | ||||||||||
Rated insulation voltage(Ui) | 690V | ||||||||||
Rated impulse withstand voltage(Uimp) | 8kV | 6kV | 8kV | ||||||||
Rated short-time withstand current(lcw) | 5kA | 10kA | 10kA | 20kA | 40kA | 60kA | 60kA | 80kA | 80kA | 100kA | 125kA |
Rated short circuit making capacity(lcm) | 7.65kA | 17kA | 17kA | 40kA | 60kA | 60kA | 80kA | 100kA | 125kA | 160kA | 200kA |
Operating endurance(times) | 10000 | 5000 | |||||||||
5000 | 2500 | ||||||||||
Pole No. | 2 | ||||||||||
3 | |||||||||||
4 | |||||||||||
Operating cycls(s/times) | 20s | ||||||||||
Switching time | 1-99s(delay) |