Quick Details
-
Brand Name:
-
Acrel
-
Model Number:
-
AGF-M24T
-
Accuracy Class:
-
Class 0.5
-
Output Voltage:
-
1000V DC
-
Operating Temperature:
-
-35~+65℃
-
Dimensions:
-
144mm*46mm*55mm
-
Rated current:
-
DC 0~20A
-
Response time:
-
1s
-
Communication:
-
RS485 modbus rtu
-
Temperature coefficient:
-
400ppm
-
Power supply:
-
DC1000V or DC1500V
Quick Details
-
Phase:
-
Single Phase
-
Measuring Energy Range:
-
0-999999.99kwh
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
Acrel
-
Model Number:
-
AGF-M24T
-
Accuracy Class:
-
Class 0.5
-
Output Voltage:
-
1000V DC
-
Operating Temperature:
-
-35~+65℃
-
Dimensions:
-
144mm*46mm*55mm
-
Rated current:
-
DC 0~20A
-
Response time:
-
1s
-
Communication:
-
RS485 modbus rtu
-
Temperature coefficient:
-
400ppm
-
Power supply:
-
DC1000V or DC1500V
Solutions & Applications
Solar PV Power Distribution Monitoring Solution
Practical Application of AGF-MxxT in PV Combiner Box
APV Smart Solar PV Combiner Box installed under PV Array
Products Description
AGF-MxxT DC Multi-Circuits Monitoring Device for PV Combiner Box
AGF-T Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus) communication port for transmitting all the datas to master device.
● Measurement: DC Current of up to 24 Circuits (with Hall Sensors); Voltage of Busbar
● Communication: RS485 (MODBUS-RTU)
● Application: Paired with PV Combiner Box for DC Multi-circuits Monitoring
● Temperature Monitoring: Inner Temperature of PV Combiner Box
● DI Function: 3-channel Digital Input
● Display: LCD Display
● Installation: 35mm DIN Rail (Main Body); Perforation (Cable)
● Power Supply: 1000V DC or 1500V DC
● Standard&Certificate: CE;LVD;EMC
Multi-circuits Measurement up to 24 DC Circuits
● Input Channel: up to 24 Circuits
● LED Indicator for Re-flux, Disconnection, Over-current
● Rated Current: 20A
● Accuracy: 0.5 Class
● Voltage Measuring Range: up to 1500V (Busbar)
3-Channel DI Switch Status Monitoring
● DI Status of Lightning Protector and DC CB
● Octocoupler or dry Contact
● Octocoupler or dry Contact
Temperature Measuring & Over-temperature Alarm Function
● Measuring the inner Temperature of DC PV Junction Box
● Thermistor: NTC
● Range of Measuring: -20℃~+100℃
Easy Installation
● Perforated Hole for Cable to pass through
● DIN Rail Installation
● Module Connected by Data Lin
Keypads HMI for Programming
● Communication(address, baud rate and etc.)
● Over-temp Alarm Threshold
LCD Display
● English Interface
● Data Display
Function & Parameter
Product Naming
Type
|
Describetion
|
|
Function
|
Optional function
|
|
AGF-M4T
|
4 circuits DC0-20A Photovoltaic confluence detaction
|
|
1.3.5KV hall isolation 2.RS485 Modbus-RTU 3.Accuracy 0.5 class
4.0-1000V voltage measurement. 5.3 sets of extemal status inputs(optocoupler or dry contact mode) 6.The auxiliary power supply can be DC1000V, DC1500V.
|
1.MJ (Analog input+ Relay output)-PT100/DC 4-20mA/DC0-10V+2 circuits normally open
2.B(power filter module) 3.L(LCD)
4.P2(Auxiliary power supply DC1000V) 5.P3(Auxiliary power supply DC1500V)
|
|
AGF-M8T
|
8 circuits DC0-20A Photovoltaic confluence detaction
|
|
|
|
|
AGF-M12T
|
12 circuits DC0-20A Photovoltaic confluence detaction
|
|
|
|
|
AGF-M16T
|
16 circuits DC0-20A Photovoltaic confluence detaction
|
|
|
|
|
AGF-M20T
|
20circuits DC0-20A Photovoltaic confluence detaction
|
|
|
|
|
AGF-M24T
|
24 circuits DC0-20A Photovoltaic confluence detaction
|
|
|
|
Dimension & Installation
Configuration of 8-channel or 4-channel confluence acquisition module will be decided by actual needs: when 4 channels or less are needed, 4-channel confluence acquisition module will be installed, when needed channel number is 5 to 8, 8-channel confluence acquisition module will be installed. When needed channel number is more than 8, then the number will be divided by 8. If there is a remainder in the result and the remainder is less than 4, then 4-channel confluence acquisition module will be installed. If the remainder is more than 4, 8-channel confluence acquisition module will be installed.