- Product Details
- {{item.text}}
Quick Details
-
Keyword:
-
hrv heat hepa recovery ventilation
-
Heat exchanger:
-
Enthaply Heat Exchanger
-
Color:
-
White and black
-
Shape:
-
Rectangle
-
Airflow:
-
150-6000CMH
-
Certificate:
-
SAA
-
MOQ:
-
1 Set
-
OFFER OEM:
-
Accept
Quick Details
-
Place of Origin:
-
China
-
Brand Name:
-
IGUICOO
-
Product name:
-
heat recovery ventilators
-
Keyword:
-
hrv heat hepa recovery ventilation
-
Heat exchanger:
-
Enthaply Heat Exchanger
-
Color:
-
White and black
-
Shape:
-
Rectangle
-
Airflow:
-
150-6000CMH
-
Certificate:
-
SAA
-
MOQ:
-
1 Set
-
OFFER OEM:
-
Accept

IGUICOO Hrv Heat Recovery Fresh Air Ventilation System Ceiling Ventilate Recuperator Energy Recovery Ventilation Hvac System
Specification
Item
|
Ventilation system/Heat recovery ventilator/Energy recovery ventilation
|
Warranty
|
1 Year
|
After-sale Service
|
Online technical support, Free spare parts
|
Project Solution Capability
|
Provide overall solution
|
Application
|
Hotel/School/Commercial building/Real estate project
|
Design Style
|
Modern
|
Place of Origin
|
China
|
Model Number
|
TFKC-015~TFKC-100 TDKC-080~ TDKC-600
|
Air Flow(m³/h)
|
1000
|
Install type
|
Ceiling
|
Maintenance
|
Side door
|
Heat Recovery Type
|
Enthalpy exchanger
|
Efficiency(%)
|
75%
|
Power Voltage(V)/Frequency(HZ)
|
110-240/50-60HZ 380V
|
OEM/ODM
|
Accept
|
Products Features
•
RH
Automation
•
Boost
Ventilation
•
DC
motor
•
Freeze
Protection Automation
•
PM2.5
Automation •
Internal CO2
Sensor
•
Internal RH
Sensor
WiFi remote intelligent control energy heat recovery ventilation system
It is built in energy saving BLDC motor, G4+H12 filter, high efficiency enthalpy heat exchanger. Ideal ventilation solution for
family homes and small commercial projects.
It is built in energy saving BLDC motor, G4+H12 filter, high efficiency enthalpy heat exchanger. Ideal ventilation solution for
family homes and small commercial projects.

Airflow: 150~1000m³/h
Model: TFKC A4 series
1. Energy saving BLDC motor, 4 speeds control
2. Filter alarm: filter dirty plugging replacement reminder
3. High efficiency enthalpy heat recovery, more comfortable indoor climate
4. G4+H12 filter, efficiency over 97% to filter the particulate from 2.5μm to 10μm
5.
Intelligent control system, standard CO2 、PM2.5、humidity control function, 485 and BMS (Building Management System)control available.

Side door.
Cross reverse flow type enthalpy exchange core has higher heat exchange and humidity exchange.

Multi-color optional
If you have special needs,we can customize for your project, such as high static pressure、110V
ERV can be used with kinds of heat pump air conditioning
The following is a partial installation diagram ↓↓↓↓
• Strong motor
Efficient quiet, efficient copper core motor, stable and reliable performance.Power consumption is reduced, saving 70% energy consumption.
• Efficient cross-flow heat exchanger
Using polymer membrane material, with high heat recovery efficiency is up to 85%,enthalpy efficiency is up to 76%, effective air exchange rate above 98%,with flame retardant,long-term antibacterial and mildew prevention function, washable, life up to 3~10 years.
In the hot season, the system precools and dehumidifies the fresh air, humidify and preheat in the cold season.
Double purification protection:
Primary filter(washable) + high efficiency filter can filter 0.3
μm
particles, and the filtration efficiency is as high as 99.9%.
Static pressure curve
We are all measured curves, our 250 airflow may be equivalent to some businesses 350 or even 500 airflow.
Within 1000m³/h, Tuya APP can be used for remote control. App is available to IOS and Android phones with the following functions:
1. Monitoring indoor air quality Monitor local weather, temperature, humidity, CO2 concentration, VOC at your hand for healthy living.
1. Monitoring indoor air quality Monitor local weather, temperature, humidity, CO2 concentration, VOC at your hand for healthy living.
2.Variable setting timely switch, speed settings, bypass/timer/filter alarm/temperature setting.
3.Optional language
Different language English/French/Italian/Spanish and so on to meet your requirement.
Different language English/French/Italian/Spanish and so on to meet your requirement.
4.Group control One APP can control multiple units.
5.Optional PC centralized control(up to 128pcs ERV controlled by one Data acquisition unit) Multiple data collectors areconnected in parallel.
Model
|
Airflow
(m³/h)
|
Rated E.S.P(Pa)
|
Temp.Eff.
(%)
|
Noise
(dB(A))
|
Power input (W)
|
N.W(Kg)
|
Size(mm)
|
TFKC-025 (A4 -1D2)
|
250
|
100
|
73-81
|
34
|
82
|
33
|
750*600*220
|
TFKC-035 (A4-1D2)
|
350
|
120
|
74-82
|
35
|
105
|
45
|
830*725*255
|
TFKC-045 (A4-1D2)
|
450
|
120
|
70-75
|
36
|
180
|
48
|
950*735*250
|
TFKC-080(A4-1D2)
|
800
|
100
|
70-75
|
42
|
500
|
80
|
1300*860*390
|
TFKC-100 (A4-1D2)
|
1000
|
120
|
70-75
|
50
|
550
|
86
|
1540*860*390
|
Airflow: 800~6000m3/h
1. AC motor, 3 speeds control
2.High efficiency enthalpy heat recovery, more comfortable indoor climate
3. G4 filter
4.≥1500m³/h airflow, using 380V voltage., without controller, more details can feel free contanct us.
About us
1.Have
2 plants
meet the capacity demands 2.Possess
80 patents
certificates
3.
10+ years
experience HVAC industry 4. Have strong
R&D and HVAC design team
5. Free installation plan design service 6.
A
full set of ventilation
system installation
pipe fitting supply
7.Have
2 laboratories
(nation
a
l approved enthanlpy and 30
m³
laboratory
8. Duilt a sound certificate system of ISO9001, ISO 14001, ISO45001, CE certificate and other product certification system.
How to choose the right equipment?
1. Choose the proper installation types based on the building structure
2. Determine the required fresh airflow based on the usage scenario, area size, and persons
3. Select the right specifications and quantity according to the determined fresh airflow
Patent certificate
Our exhibition
Packing & Shipping
FAQ
Q1: How could I get a sample?
A:We do not provide free sample, if you are interested in our products please contact our customer
service, she can tell you the details of the sample.
Q2: Sample time?
A: Existing products: Within 15~35 days;
Q3: Whether you could make our brand on your products?
A: Yes. We can print your Logo on both the products and the packages if you can meet our MOQ.
Q4: Whether you could make your products by our color?
A: Yes, The color of products can be customized if you can meet our MOQ.
Q5: How to guarantee the quality of your products?
A: 1) Strict detection during production.
2) Strict sampling inspection on products before shipment and intact product packaging ensured.
service, she can tell you the details of the sample.
Q2: Sample time?
A: Existing products: Within 15~35 days;
Q3: Whether you could make our brand on your products?
A: Yes. We can print your Logo on both the products and the packages if you can meet our MOQ.
Q4: Whether you could make your products by our color?
A: Yes, The color of products can be customized if you can meet our MOQ.
Q5: How to guarantee the quality of your products?
A: 1) Strict detection during production.
2) Strict sampling inspection on products before shipment and intact product packaging ensured.
Hot Searches