- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Liaoning, China
-
Brand Name:
-
Qiaogong
-
Dimension(L*W*H):
-
2250*460*720mm
-
Weight (KG):
-
145 KG
-
Product name:
-
Gas fired air curtains
-
Heating medium:
-
NG LPG
-
Mounting height:
-
<6m
-
Outlet air velocity:
-
10m/s
-
Heating capacity:
-
50KW/ 170000BTU
-
Thermal efficiency:
-
99%
-
Standard gas flow rate(NG):
-
4.83 m3/h
-
Standard gas flow rate(LPG):
-
4.11kg/h
-
Electric Power:
-
0.78kW
-
Noise:
-
<65dB(A)
Quick Details
-
Type:
-
Air Curtain
-
Mounting:
-
Installed above the door
-
Airflow:
-
10000m³/h
-
Place of Origin:
-
Liaoning, China
-
Brand Name:
-
Qiaogong
-
Dimension(L*W*H):
-
2250*460*720mm
-
Weight (KG):
-
145 KG
-
Product name:
-
Gas fired air curtains
-
Heating medium:
-
NG LPG
-
Mounting height:
-
<6m
-
Outlet air velocity:
-
10m/s
-
Heating capacity:
-
50KW/ 170000BTU
-
Thermal efficiency:
-
99%
-
Standard gas flow rate(NG):
-
4.83 m3/h
-
Standard gas flow rate(LPG):
-
4.11kg/h
-
Electric Power:
-
0.78kW
-
Noise:
-
<65dB(A)
General Information
The primary reason for installing gas fired air curtains is to prevent the influx of cold outside air through a door opening into a heated area.
Typical applications include large dispatch bay doors in factories , shopping malls and warehouses, and internal doors between areas of different temperatures. Wider door openings can be accommodated by bolting two or more units together.
Product features
· Indirect combustion heat exchange.
· Built-in stainless steel heat exchanger.
· The gas fired unit heater is installed with a fan to force the fume exhaust
out of the room.
· Low NO X emission.
· The thermal efficiency up to 99%.
· Modular design, can be used in combination.
Standard configurations
· Gas leak alarm.
· Accidental flameout protection.
· Equipment overheating protection.
· Preset upper temperature limit.
· Equipment status self-check.
· Intelligent network control interface.
· The unit heater has a local switch.
· The unit heater can be connected to the remote switch.
Optional configurations
· Intelligent network controller(One control twenty)
· Digital display controller
· Interlock with door
The main technical parameters
Type | Industrial | Commercial | ||
Model | RM-40175Z-R | RM-40225Z-R | DRM-2518L-R | DRM-2522L-R |
Mounting height m |
<6 | <6 | <4.2 | <4.2 |
Dimensions(L*W*H) mm | 1750*460*720 | 2250*460*720 | 1800*600*380 | 2200*600*380 |
Air flow m 3 /h |
7500 | 10000 | 6000 | 7200 |
Outlet air velocity m/s | 10 | 10 | 13 | 13 |
Heat input kW/Hr | 40 | 50 | 35 | 45 |
Thermal efficiency | 99% | 99% | 99% | 99% |
Standard gas flow rate (NG) m3/h |
3.86 | 4.83 | 3.38 | 4.35 |
Min.gas flow rate (NG) m3/h |
2.32 | 2.9 | 2.03 | 2.61 |
Standard gas flow rate (LPG ) m3/h |
3.29 | 4.11 | 2.88 | 3.77 |
Min.gas flow rate (LPG) m3/h |
1.97 | 2.47 | 1.73 | 2.22 |
Gas pipe diameter inch | 3/4" | 3/4" | 3/4" | 3/4" |
Flue nominal bore mm | 100 | 100 | 80 | 100 |
Electrical power kw
|
0.63 | 0.78 | 0.95 | 1.13 |
Noise dB(A) | 65 | 65 | 55 | 55 |