- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Chongqing, China
-
Brand Name:
-
Atomic Absorption Spectrophotometer
-
Model Number:
-
GD-4530F XRF Precious Metal Analyzer
-
Focal Length:
-
015mm
-
Wavelength Range:
-
190nm-900nm
-
Application:
-
Residual Fuel Oils Metal Analyzer Spectrometer
-
Apparatus:
-
AAS Mining Sample Analyzer Atomic Absorption Spectrophotometer
-
Usage:
-
AAS,Soil Contamination Analyzer,Gold in Soil Analyzer
-
Device:
-
AAS Spectrophotometer Metal Element Analyzer
-
Working mode:
-
Flame/Graphite Furnace Atomic Absorption Spectrophotometer
-
Detection limit:
-
PPM or PPB
-
Accuracy of the wavelength:
-
0.15nm
-
Base line stability:
-
0.002A/30min (Cu)
-
Preciseness:
-
0.5%
Quick Details
-
Warranty:
-
3 years
-
Size:
-
700x550x450(mm)
-
Weight:
-
75kg
-
Place of Origin:
-
Chongqing, China
-
Brand Name:
-
Atomic Absorption Spectrophotometer
-
Model Number:
-
GD-4530F XRF Precious Metal Analyzer
-
Focal Length:
-
015mm
-
Wavelength Range:
-
190nm-900nm
-
Application:
-
Residual Fuel Oils Metal Analyzer Spectrometer
-
Apparatus:
-
AAS Mining Sample Analyzer Atomic Absorption Spectrophotometer
-
Usage:
-
AAS,Soil Contamination Analyzer,Gold in Soil Analyzer
-
Device:
-
AAS Spectrophotometer Metal Element Analyzer
-
Working mode:
-
Flame/Graphite Furnace Atomic Absorption Spectrophotometer
-
Detection limit:
-
PPM or PPB
-
Accuracy of the wavelength:
-
0.15nm
-
Base line stability:
-
0.002A/30min (Cu)
-
Preciseness:
-
0.5%
Products Description
GD-4530F XRF Precious Metal Analyzer/Metal Analyzer Spectrometer
♣ Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)
♣ Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.
♣ Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp
♣ Position adjusting: the best height of the flame burner and can automatically set the front and rear positions
♣ Fully automated wavelength scanning and peak searching
♣ Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout
♣ Deuterium lamp and self-absorption background regulation
♣ Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called
♣ Measuring method: flame absorption method and emission method
♣ Result printing: parameter printing, data result printing and diagram printing
Complete Automatic Controlling System of 4530F XRF Precious Metal Analyzer/Metal Analyzer Spectrometer With the help of the software, the following can be easily achieved
♣ Selection of the element lamp
♣ Up-down-front-rear adjustment of the lifter
♣ Adjustment of the optical energy
♣ Selection of the slit
♣ Determination of wavelength scanning and peak searching
♣ Selection of the atomizer
♣ Setting of the background deduction method
♣ Controlling of the gas flow
♣ Automatic flaming and flaming out
♣ Setting of the graphite furnace testing method
Advanced Graphite Furnace Temperature Controlling Technology
♣ The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3m s/time fast sampling technique can make more accurate and reliable testing data
♣ The fast heating capacity can improve the flexibility of the elements further
♣ Use the ordinary power source of 220V without need of dynamic power of 380V
♣ The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
♣ Three grades adjustable gas flow can accustom to more application needs
♣ Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error
Safe, Reliable and Convenient Flame System
♣ Epc can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily
♣ Efficient Atomization system enables a higher sensitivity
♣ The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage.
Multi-functional Software Workstation
♣ A workstation that is supported WINDOWS XP/2000/NT
♣ The rich menu brings great convenience to the use of customer
♣ Convenient conversion between different menus makes the operation more easily
♣ Various analytical correction methods provide the users more choices
♣ Basic default parameter settings enable even the beginners can do the normal operation
♣ Flexible storage, editing and printing methods give the user largest support
Instrument Configuration
♣ Atomic Absorption Spectrophotometer 1pc
♣ Air compressor without noise 1pc
♣ PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configurat ion)
♣ A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)
4530F AAS Specifications
1
|
Wavelength range
|
190 – 900nm
|
2
|
Spectral bandwidth
|
Can automatically change between 0.1nm,0.2nm,0.4nm,1.0nm and 2.0nm
|
3
|
Accuracy
|
±0.15nm
|
4
|
Receptivity of the wavelength
|
≤0.04nm
|
5
|
Base line stability
|
≤0.002A/30min (Cu)
|
6
|
Characteristic viscosity
|
0.02μg/ml/1% (Cu)
|
7
|
Checking limit
|
0.004μg/ml (Cu)
|
8
|
Preciseness
|
0.50%
|
9
|
Grating
|
1800 lines/mm
|
10
|
Inflamer
|
All-metal titanium burner
|
11
|
Atomizer
|
Effective glass atomizer
|
12
|
Lamp turrets
|
Eight lamps
|
13
|
Size and weight
|
700mm×550mm×450mm 75Kg
|
14
|
Power source
|
220V±22V AC
|
Note: