Quick Details
-
Model Number:
-
SY-B032
-
Place of Origin:
-
Guangdong,China
-
Wavelength:
-
470nm
-
Quality System:
-
Recognized by CE TUV and CMD
-
Voltage:
-
AC 85V~264V,Auto adapt according to the input voltage
-
Humidity:
-
20%RH-80%RH
-
Test Method:
-
Dispersion light nephelometric analysis
-
Light Source:
-
Cold Lamp with high brightness and long lifetime
-
Power:
-
≤80W
-
Working Environment:
-
Temperature:10℃~30℃
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Online technical support
-
Brand Name:
-
SUNNYMED
-
Model Number:
-
SY-B032
-
Place of Origin:
-
Guangdong,China
-
Wavelength:
-
470nm
-
Quality System:
-
Recognized by CE TUV and CMD
-
Voltage:
-
AC 85V~264V,Auto adapt according to the input voltage
-
Humidity:
-
20%RH-80%RH
-
Test Method:
-
Dispersion light nephelometric analysis
-
Light Source:
-
Cold Lamp with high brightness and long lifetime
-
Power:
-
≤80W
-
Working Environment:
-
Temperature:10℃~30℃
Product Description
Specification
Test Method: Dispersion light nephelometric analysis
Test Principle: The highest point on first order differentiation, Percentage analysis
Zero point correction: Auto track the zero point, eliminate the effect
of sample and reagent
Wavelength: 470nm
Light Source: Cold Lamp with high brightness and long lifetime
Detector: Unique dispersion light detector with high sensitivity
and repeatability, immunized the effect
on result of jaundice,hemolysis,chyle and turbidity on plasma
Test Channel: 4 channels,each channel is independent,
one or more same or different items can be test
Simultaneously
Incubator: Provide 28 incubators for reagent and sample
Incubator Temperature:37±0.2℃
Measure trigger: Auto trigger the measurement through configured pipette
Item modify: easy to add or edit items, easy to set the items parameters
Calibration: single-point calibration;
multipoint calibration; auto store and match with calibration curve
Quality control: Auto draw the QC figure
Reagent: Open reagent system
Reagent volume: ≤40μL
Sample volume: ≤40μL
Memory: Save more than 10000 samples results,
and auto recover the results when power is off during Working condition
Repeatability: CV≤5%
Calculative item: S,
%,PTR,INR,Fib can be get through PT, This leads to lower the cost of reagent
Printer: Inner thermal printer,can be connected to external printer
Information edit: easy to input and edit the detail information of patients
Interface: RS-232 serial port,can be connected to external printer and computer
Test Principle: The highest point on first order differentiation, Percentage analysis
Zero point correction: Auto track the zero point, eliminate the effect
of sample and reagent
Wavelength: 470nm
Light Source: Cold Lamp with high brightness and long lifetime
Detector: Unique dispersion light detector with high sensitivity
and repeatability, immunized the effect
on result of jaundice,hemolysis,chyle and turbidity on plasma
Test Channel: 4 channels,each channel is independent,
one or more same or different items can be test
Simultaneously
Incubator: Provide 28 incubators for reagent and sample
Incubator Temperature:37±0.2℃
Measure trigger: Auto trigger the measurement through configured pipette
Item modify: easy to add or edit items, easy to set the items parameters
Calibration: single-point calibration;
multipoint calibration; auto store and match with calibration curve
Quality control: Auto draw the QC figure
Reagent: Open reagent system
Reagent volume: ≤40μL
Sample volume: ≤40μL
Memory: Save more than 10000 samples results,
and auto recover the results when power is off during Working condition
Repeatability: CV≤5%
Calculative item: S,
%,PTR,INR,Fib can be get through PT, This leads to lower the cost of reagent
Printer: Inner thermal printer,can be connected to external printer
Information edit: easy to input and edit the detail information of patients
Interface: RS-232 serial port,can be connected to external printer and computer
Working Environment
|
37±0.2ºC
|
|
Temperature
|
10℃~30℃;
|
|
Humidity
|
20%RH-80%RH
|
|
Voltage
|
AC 85V~264V,Auto adapt according to the input voltage
|
|
Power
|
≤80W
|
|
Quality System
|
Recognized by CE TUV and CMD
|