Products
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock
UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock

UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock

FOB Reference Price: Get Latest Price
≥10 Sets
US $119
≥100 Sets
US $109
≥200 Sets
US $99
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Application:
Hotel
Design Style:
Modern
Place of Origin:
Liaoning, China
Brand Name:
Golden House
Material:
galvanized steel
Color:
grey color
Certificate:
WHI/FM
Name:
double swing steel fire door
Surface:
Finished Steel
Function:
Anti-fire
Size:
6070/8080
Infilling:
Polystyrene/Honrycomb/Mineral fire board
Special Door Type:
Fire Doors
Position:
Commercial

Quick Details

Door Material:
Steel
Feature:
fire prevention
Main Material:
Steel
Application:
Hotel
Design Style:
Modern
Place of Origin:
Liaoning, China
Brand Name:
Golden House
Material:
galvanized steel
Color:
grey color
Certificate:
WHI/FM
Name:
double swing steel fire door
Surface:
Finished Steel
Function:
Anti-fire
Size:
6070/8080
Infilling:
Polystyrene/Honrycomb/Mineral fire board
Special Door Type:
Fire Doors
Position:
Commercial

UL listed approve 180 minute steel commercial emergency exit fire rated door with panic bar lock

Product Description

steel fire door feature:

fire rated up to 3 hours with WHI  UL  FM label applied .

all of doors are designed and fabricated under SDI requirements.

1 3/4" thickness (44.5mm),non-handed assemble with reversible hinge shim parts.

fire rated wire glass or louver option for vision lites .

all materials is  approved  in accordance with NFPA  ASTM and other standards .

steel stiffener, hardware preparations and reinforcement are conformed with ANSI standards .

GH Steel Fire Door Technical Data :

Brand

Golden House (GH)

Standard

UL 10(b),UL 10(c) /NFPA/ASTM /UBC7-2

Certifications

INTERTEK(WHI),FM,UL

Fire rated time

45min,90min,up to 180 min

Door Size (single)

standard width up to 4'0"(1200mm ) Height  up to 8'0"(2440mm);

customized size is available .

Leaf thickness:1 3/4" standard ( 44.5mm )

Frame jamb depth:100-300mm

Door size (Double)

Maximum size is 8'x8'(2440x2440mm)

Door leaf sheet

20Ga-18Ga (1.0/1.2mm).customized level is available

Door frame sheet

16Ga.(1.5mm) ,customized level is available

Opening

swing /inward or outward

Type

2panel/6panel/flush panel/vision lite /louver

Material of leaf and frame

cold roll steel or Galvanized Steel or Galvannealed Steel

Filling material

Honeycomb,Polystyrene,Mineral Fire Board

Surface finish

factory Primer /finsih paint/power coated/wood grain finished

Color

RAL color system or be customized as well

Application

Suitable for building project,business,home decoration (Office,hotle,church,home and so on )

Packing

in wooden case or steel pallet package


Structure & Frame

FIRE DOOR FRAMES

Frame used in masonry walls maybe used with a maximum 3-hour fire door while frame used in drywall stud walls are intended to be used with a maximum 1-1/2-hour fire door. consulting with your door frame manufacturers listings for fire door frames than can be used in drywall stud walls with a maximum 3-hour ratings.

Certifications

Fire-Rated doors are required to be suited for the various type of walls as below :

Frame and Hardware must also carry the appropriate fire label

Door fire Rating Wall Rating Description and Use
3 Hour 4 Hour The openings are in wall that separating buildings or dividing a single building into designated fire areas.doors for this openning are required at 3 hours fire rating.
1-1/2 Hour 2 Hour Openings  are used in enclosures of vertical communication or egress through buildings. theste could be stairwells or elevator shafts. They also are in boiler rooms and in exterior walls that have the potential for severe fire exposure from the outside of the building.

3/4 Hour

(45 Minutes)

1 Hour For use on the  openings are in corridors and room partitions. A door with this rating may also be used in the exterior wall which are subject to moderate fire exposure from the outside of the building.

1/3 Hour

(20 Minutes)

1 Hour These openings are in corridors or interior partitions where this fire rating is required .

Door Type & Photo

FIRE DOOR TYPES

Anchor&Hardware

Client Comments

Overseas Warehouse

Los Angeles distribution center :

Address:14300 Alondra Blvd. La Mirada, CA. 90638 Los Angeles,USA

Tel: 714 562 8808

Vancouver distribution center :

Address: #1185 1579 Kingsway Ave Port Coquitlam, BC. V3C 1S2 Vancouver,Canada

Tel: 604 475 6679

Quality control

1991--Golden house started production of metal and wood fire door.

1998-- expanded production plant , a large production line covering area is 1, 200,000 sq.

2003—imported German solid wood and metal door production line.

2006--become the first factory who possesses INTERTEK WH and UL  FM fire certificates.

2007--Set up a distribution center with big warehouse containing 6000 doors in Los Angeles USA.

2012--Set up a distribution center with warehouse containng 5000 doors  in Vancouver Canada.

2015--Authorized WHI fire label with fire-rated 3 hours on double steel door  and UL fire label with fire-rated 20 minutes on wooden door.

2018--Authorized UL fire label with fire-rated 90 minutes on steel doors.

2019--Authorized WHI fire label with fire-rated 90 minutes on wooden door matched steel frame.

2020--Authorized UL fire label with fire-rated 3 hours on steel door and frame.

2021--Authorized the 34dB sound insulation steel door certificate.

2022--Fire Door Glass Light Frames holder is UL certified

2023--Certified with temperature rising fir door with 60 mins

packaging & shipping

FAQ


Q1:Can be mixed different colors and models together in one order?
A1:Surely yes. Mixed colors and models are acceptable in One 20GP or in one 40HQ we suggested 3-6 models.

Q2:Can you make the door according to our drawing?
A2:Yes,we can.But customer should send us drawing to check firstly,then we shall reponse you the correct drawing for production .


Q3: What’s your policy for samples?
A3:For small sample,we can offer for free.For completely doors ,we have to charge some cost on actual situation. But we will refund the sample charge to you if you place bulk order next time.

Q4: What’s your special service?
A4:Overseas installation service.

Q5: How to order Delivery time?
A5: Delivery time: About 20-35days.
First we need know your specific door request and specs, then we issue the related solutions to meet your requirements. After that, we make the invoice and drawings for your approval. Once you approve the both, 50% deposit will be arranged and the production is started; after the order is finished, we take video or pictures to you, or you dispatch inspector here, then collect the balance before shipping.

Q6:Do you have stock?
A6:we stock American standard hollow metal door & frames as procedure in factory. When your order is special and need customerized , we need arrange that specially, just like project schedule, most of them need customerized by specific size, color, lock type, materials, etc. So, we can pick up wholesaler order or end user project order both.