LR series method of hypochlorite disinfectant generator together (electrolysis), plate test using the latest technology,add sodium
salt solution which contain chlorine into generator , by electrolysis produce hypochlorous acid liquid sterilization equipment.
Have excellent synergy broad-spectrum sterilization ability, can quickly and effectively kill the hay bacillus coli, pseudomonas
aeruginosa, savary-gilliard door, legionella bacteria and e. coli bacteria, etc.; For typhoid fever, hepatitis b, such as cholera
virus has good killing effect. And don't generate chlorinated organic compounds (carcinogenic, teratogenic and cause material).
The equipment material purchasing sodium chloride is convenient, is the world recognized the ideal alternative products in the
field of drinking water disinfection. Its working principle in electrolytic cell anode add sodium salt solution of chlorine,
cathode indoor water, electrolytic just by turning on the power supply. At the same time in the anode chamber to produce a variety
of pure disinfection gases, dose into the untreated water.
- Product Details
- {{item.text}}
Quick Details
-
Name:
-
Ozone Generator
-
Function:
-
Water Purification Plant
-
Filter Media:
-
ozone
-
Voltage:
-
customized
-
Processing:
-
Molded
-
Product Keywords:
-
ozone
Quick Details
-
Place of Origin:
-
China
-
Product name:
-
Ozone Generator
-
Application:
-
Water Disinfection
-
Name:
-
Ozone Generator
-
Function:
-
Water Purification Plant
-
Filter Media:
-
ozone
-
Voltage:
-
customized
-
Processing:
-
Molded
-
Product Keywords:
-
ozone
Product Description

Composition:
Salt tank, electrolytic tank, cooling system, intelligent electrolytic power supply, control system, safety protection system
Salt tank, electrolytic tank, cooling system, intelligent electrolytic power supply, control system, safety protection system
Product Description
Reaction principle

3.Advantage:
3.1 Unique titanium using ruthenium, iridium, rhodium, platinum five yuan rare metals such as coating, stable performance, the
electrolysis efficiency is high, no clean, resistance to corrosion
3.2 Unique new plate plate in use process, no cleaning and maintenance, long service life (more than three years), stable
performance, low resistance, can automatically balance, to achieve the best efficiency, lower power consumption, salt consumption,
operation cost is reduced.
3.3Unique pump circulation system (imported from Japan IWAKI company), keep electrolytic solution componentsalways stay in dynamic
balance, guarantee the stability of equipment operation, ensure application effect of the equipment.
3.4 Unique heating exchange system and equipment overheating protection system, to ensure that heating transfer effect keep
optimum. to avoid the equipment in electrolysis process, because of heating production and make the equipment interior temperature
over 80 ℃, cause electrolyte membrane degeneration, aperture larger permeability increase, at the same time, to avoid the
deformation caused the decline of the UPVC material strength used equipment.
3.5 The unique LR series method hypochlorous acid mixing high efficient sterilizer special cathode, anode, electrochemical high
efficiency, long service life
3.6 Unique high-frequency electrolysis power makes the LR series hypochlorous acid mixed efficient sterilizer work more stable,
and realized the full automation of the equipment; And remote computer operation or with on-line flowmeter and residual chlorine
instrument to realize automatic closed-loop control.
3.7Generator all made of UPVC titanium composite materials and other corrosion resistant equipment corrosion, long service life
3.8 Sodium hypochlorite disinfectant site preparation, negative pressure dosing, safety and reliability of the operation of the
generator
3.9 According to user needs, by receiving flowmeter, 4-20 ma residual chlorine sensor signal to realize automatic closed-loop
control or remote computer control
electrolysis efficiency is high, no clean, resistance to corrosion
3.2 Unique new plate plate in use process, no cleaning and maintenance, long service life (more than three years), stable
performance, low resistance, can automatically balance, to achieve the best efficiency, lower power consumption, salt consumption,
operation cost is reduced.
3.3Unique pump circulation system (imported from Japan IWAKI company), keep electrolytic solution componentsalways stay in dynamic
balance, guarantee the stability of equipment operation, ensure application effect of the equipment.
3.4 Unique heating exchange system and equipment overheating protection system, to ensure that heating transfer effect keep
optimum. to avoid the equipment in electrolysis process, because of heating production and make the equipment interior temperature
over 80 ℃, cause electrolyte membrane degeneration, aperture larger permeability increase, at the same time, to avoid the
deformation caused the decline of the UPVC material strength used equipment.
3.5 The unique LR series method hypochlorous acid mixing high efficient sterilizer special cathode, anode, electrochemical high
efficiency, long service life
3.6 Unique high-frequency electrolysis power makes the LR series hypochlorous acid mixed efficient sterilizer work more stable,
and realized the full automation of the equipment; And remote computer operation or with on-line flowmeter and residual chlorine
instrument to realize automatic closed-loop control.
3.7Generator all made of UPVC titanium composite materials and other corrosion resistant equipment corrosion, long service life
3.8 Sodium hypochlorite disinfectant site preparation, negative pressure dosing, safety and reliability of the operation of the
generator
3.9 According to user needs, by receiving flowmeter, 4-20 ma residual chlorine sensor signal to realize automatic closed-loop
control or remote computer control


4.Application scope
1. Equipment product design, the manufacture should comply with the specifications and standards
JB2932 water treatment equipment manufacturing technology condition
GB/T1002.1-1996 water supply use rigid polyvinyl chloride (PVC -u) pipe
GB/T4219—1996 Chemical with rigid polyvinyl chloride (PVC -u) pipe
GB/T4454—1996 Hard PVC laminate material
GB/T17218-1998 Domestic drinking water transport and distribution protective material safety evaluation standard
GB5749 drinking water sanitary standard
HJ/T272-2006 Sodium hypochlorite disinfectant generator
GB2682 Electrical complete sets equipment of light and color of the button
ZDJ98003-87 Water treatment equipment, paint, packaging technology
GB178—85 Industrial noise control design specification
GB11984-89 Sodium hypochlorite safety procedures
2.Technical parts
Our technology, equipment, materials should be provided by the performance, quality of similar products in the best, the supplied
equipment can fully meet the needs of users requirements: good operation records. System, reliable monitoring, alarm instrument,
to supervise, judge system equipment running status. System with reliable safety protection measures. Cooling water dosage are
rare.
Equipment and systems which contact with salt water, sodium hypochlorite solution, acid liquor PVC plastic pipes, pipe fittings,
valves use PVC plastic valve. System instruments, meters, all according to the corrosion medium pump (salt water, selection of
sodium hypochlorite solution and acid liquor). All pipe, valves, pipe fittings and so on pressure level should match the
corresponding system pressure rating.
Sterilization system equipment in accordance with the identified process to remove algae in the approved drawings and
manufacturing technical documentation. Must set up the enclosure grounding bolt, shell part and power part of the metal structure
and the grounding bolt, a reliable electrical connection between real connection resistance values < 0.1, grounding bolt has
obvious signs
The generating sodium hypochlorite solution physical chemical property : clear transparent, no visible impurities.
Air blower air volume and air pressure to meet under the condition of sodium hypochlorite generator rating runtime hydrogen
concentration will be diluted to less than 1%.
Algae removal system of sterilization equipment before delivery are processed according to the requirements of relevant standards
for protection. The color of the paint protection processing equipment of the paint by the tenderee and the design institute for
confirmation.
3. power source
voltage:3 phase four wire system(380/220V)
power mains frequency:50Hz
4. Operating environment
Equipment layout: The preparation of sodium hypochlorite and dosing device, power supply and other indoor decorate;
Environment temperature: indoor 5~35℃,outdoor -36.5~40℃
Annual medial humidity:65%
1000g/h sodium hypochlorite generator
JB2932 water treatment equipment manufacturing technology condition
GB/T1002.1-1996 water supply use rigid polyvinyl chloride (PVC -u) pipe
GB/T4219—1996 Chemical with rigid polyvinyl chloride (PVC -u) pipe
GB/T4454—1996 Hard PVC laminate material
GB/T17218-1998 Domestic drinking water transport and distribution protective material safety evaluation standard
GB5749 drinking water sanitary standard
HJ/T272-2006 Sodium hypochlorite disinfectant generator
GB2682 Electrical complete sets equipment of light and color of the button
ZDJ98003-87 Water treatment equipment, paint, packaging technology
GB178—85 Industrial noise control design specification
GB11984-89 Sodium hypochlorite safety procedures
2.Technical parts
Our technology, equipment, materials should be provided by the performance, quality of similar products in the best, the supplied
equipment can fully meet the needs of users requirements: good operation records. System, reliable monitoring, alarm instrument,
to supervise, judge system equipment running status. System with reliable safety protection measures. Cooling water dosage are
rare.
Equipment and systems which contact with salt water, sodium hypochlorite solution, acid liquor PVC plastic pipes, pipe fittings,
valves use PVC plastic valve. System instruments, meters, all according to the corrosion medium pump (salt water, selection of
sodium hypochlorite solution and acid liquor). All pipe, valves, pipe fittings and so on pressure level should match the
corresponding system pressure rating.
Sterilization system equipment in accordance with the identified process to remove algae in the approved drawings and
manufacturing technical documentation. Must set up the enclosure grounding bolt, shell part and power part of the metal structure
and the grounding bolt, a reliable electrical connection between real connection resistance values < 0.1, grounding bolt has
obvious signs
The generating sodium hypochlorite solution physical chemical property : clear transparent, no visible impurities.
Air blower air volume and air pressure to meet under the condition of sodium hypochlorite generator rating runtime hydrogen
concentration will be diluted to less than 1%.
Algae removal system of sterilization equipment before delivery are processed according to the requirements of relevant standards
for protection. The color of the paint protection processing equipment of the paint by the tenderee and the design institute for
confirmation.
3. power source
voltage:3 phase four wire system(380/220V)
power mains frequency:50Hz
4. Operating environment
Equipment layout: The preparation of sodium hypochlorite and dosing device, power supply and other indoor decorate;
Environment temperature: indoor 5~35℃,outdoor -36.5~40℃
Annual medial humidity:65%
1000g/h sodium hypochlorite generator
Model list
seri no
|
item
|
specification
|
unit
|
Qty
|
manufacturer
|
1
|
sodium hypochlorite generator
|
LR-1000
|
set
|
1
|
YIMEI
|
2
|
high frequency switching power
|
GGDF-1000A/12V
|
set
|
1
|
HEBEI
|
3
|
anode plate
|
LR-1000
|
set
|
1
|
YIMEI
|
4
|
cathode plate
|
LR-1000
|
set
|
1
|
YIMEI
|
5
|
salt water metering pump
|
Q=100L
|
set
|
1
|
Italy
|
6
|
dosing meter pump
|
Q=100L
|
set
|
1
|
Italy
|
7
|
liquid level gauge
|
Wy-100
|
set
|
1
|
Shanghai
|
8
|
filter
|
DN25
|
set
|
1
|
YIMEI
|
9
|
liquid level sensor
|
Xk-100
|
set
|
1
|
Jiangsu
|
10
|
cooling system
|
LR1000
|
set
|
1
|
zhejiang
|
11
|
salt water tank
|
PEV5M3
|
set
|
1
|
zhejiang
|
12
|
sodium hypochlorite tank
|
PEV5M3
|
set
|
1
|
beijing
|
Recommend Products
Our Advantages
Hot Searches