Quick Details
-
Brand Name:
-
CNC
-
Model Number:
-
YCQ9M
-
Rated Current:
-
16A-630A
-
Rated inpulse withstand voltage(KV):
-
8
-
Whether the smart:
-
Yes
-
Poles:
-
3P, 4P
-
Rated short circuit breaking capacity (I:
-
50 KA
-
Mechanical life:
-
5000
-
Electrical life:
-
1000
-
Original:
-
YCB9M
-
Rated operational current (Ie):
-
16A-630A
-
Max. Voltage:
-
AC 400V
-
Rated operational voltage (Ue):
-
AC 400V
Quick Details
-
Type:
-
smart
-
Number of Pole:
-
3
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
CNC
-
Model Number:
-
YCQ9M
-
Rated Current:
-
16A-630A
-
Rated inpulse withstand voltage(KV):
-
8
-
Whether the smart:
-
Yes
-
Poles:
-
3P, 4P
-
Rated short circuit breaking capacity (I:
-
50 KA
-
Mechanical life:
-
5000
-
Electrical life:
-
1000
-
Original:
-
YCB9M
-
Rated operational current (Ie):
-
16A-630A
-
Max. Voltage:
-
AC 400V
-
Rated operational voltage (Ue):
-
AC 400V
Product Category
Product Description
3p Ats 32 Amp 4 PolesS Automatic Transfer Switch 63A
YCQ9M Automatic Transfer Switch
Product Detail
Rated inpulse withstand voltage(KV) | 8 |
Whether the smart | Yes |
Poles | 3P, 4P |
Rated short circuit breaking capacity (I | 50 KA |
Mechanical life | 5000 |
Electrical life | 1000 |
Original | YCB9M |
Rated operational current (Ie) | 16,25,32,40,50,63,80,100,125,160,180,250,....400,630 |
Max. Voltage | AC 400V |
Rated operational voltage (Ue) | AC 400V |
Product Keywords | 3p 63a ats,transfer switch automatic 32 amp,4 polesS automatic transfer switch 63A |
Product Overview
Ensure un-interruptible service of critical electric power
When overvoltage, under-voltage or phase failure occur to a power supply, it will
automatically switch over to another power supply or start the electric generator.
It is mainly used in hospital, shopping mall, bank, hotel, high buildings and fire
control where long time power disconnection is not allowed and ceaseless power
supply is needed.
Full automatic power supply changeover system
It is equipped with three changeover methods including self-throwing and self-
reset (power network to power network), self-throwing and not self-reset (power
network to power network), self-throwing and self-reset (power network to power
generation), in order to satisfy different power changeover requirement.
Intelligent
It has communication interface with built-in RS485, and has two kinds of
communication agreement including MODBUS-RUS and electric meter 1997,
which can realize real time data upload, distance data configuration and condition
monitor, and can achieve the function of telecommand, telemetering, remote
control, and remote regulating. Remote vision can be achieved through matching
intelligent power distribution system.
Safe and reliable, and have fire control linkage function
When fire disaster occurs to no fire control load, fire protection control center can
send signal to intelligent controller, cut off double power supply, ensure fire
disaster load to break.