X-fluorescence sulfur meter is a new type of quantitative analysis instrument with microcomputer. The instrument is based on the X-fluorescence energy dispersion principle, the use of environmentally friendly X-ray tube excitation technology, the use of nuclear electronics and microcomputer together to form an advanced physical measurement method of analysis instruments; Detection without any chemical reagents, than the chemical analysis method is accurate, fast, the fastest 60 seconds to detect the sulfur content in liquid, solid powder samples.
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
ADDITION
-
Model Number:
-
JF180
-
Product name:
-
X Ray Fluorescence Sulfur Content in Oil Analyzer
-
Application:
-
Crude oil, diesel, solid powder samples, lubricants
-
Standards:
-
ASTM D4294
-
Sulfur measurement range:
-
7ppm or more
-
Sample volume:
-
2 - 3ml
-
Measurement time:
-
60, 120, 240 s
-
Repeatability:
-
<0.02894 (X+0.1691)
-
Reproducibility:
-
<0.1215 (X+0.05555)
Quick Details
-
Warranty:
-
1 Year
-
Power:
-
Electronic
-
Place of Origin:
-
Hunan, China
-
Brand Name:
-
ADDITION
-
Model Number:
-
JF180
-
Product name:
-
X Ray Fluorescence Sulfur Content in Oil Analyzer
-
Application:
-
Crude oil, diesel, solid powder samples, lubricants
-
Standards:
-
ASTM D4294
-
Sulfur measurement range:
-
7ppm or more
-
Sample volume:
-
2 - 3ml
-
Measurement time:
-
60, 120, 240 s
-
Repeatability:
-
<0.02894 (X+0.1691)
-
Reproducibility:
-
<0.1215 (X+0.05555)
Product Description
X-Fluorescence Sulfur Content Analyzer
Specification
item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM, ODM, OBM, Software reengineering
|
Place of Origin
|
China
|
|
Hunan
|
Brand Name
|
ADDITION
|
Model Number
|
JF180
|
Power
|
Electronic
|
Detection limit
|
7ppm or more
|
Sample consumption
|
2-3ml
|
Measurement time
|
60, 120, 240 s
|
Product Paramenters
1. Sulfur measurement range: 7ppm or more.
2. Sample volume: 2~3ml;
3. Measurement time: 60, 120, 240 seconds, arbitrary setting;
4. Precision: Repeatability : <0.02894 (X+0.1691);
Reproducibility : <0.1215 (X+0.05555);
5. Power source: AC220V, 50Hz
6. Size: 468*358*158mm
7. Weight <12kg
2. Sample volume: 2~3ml;
3. Measurement time: 60, 120, 240 seconds, arbitrary setting;
4. Precision: Repeatability : <0.02894 (X+0.1691);
Reproducibility : <0.1215 (X+0.05555);
5. Power source: AC220V, 50Hz
6. Size: 468*358*158mm
7. Weight <12kg
Functional characteristics
1.
Selection of the working curve, no need to manually select the curve of the corresponding range according to the size of
the sulfur content.
2. Automatically stabilize the spectrum and peak or determine the peak position through the instrument screen film, no
longer need the user to open the outer cover to manually adjust the detector high voltage.
3. The instrument AC 220v / DC 12v two power supply mode, convenient for customers to use in the field.
4. The kernel of the instrument is like a computer, which can be extended according to the special needs of different users,
and can be upgraded remotely through the usb port of the instrument.
5. Unique mechanical structure design, into and out of the sample feeding operation almost silent.
6. Single sample automatic measurement, the number of measurements: 2, 3, 5, 10, 50 times set, the average value and
standard deviation are given at the end of the measurement;
7. Calibration curve number: the instrument can store 9 calibration curves, 5 for the monomial linear, 4 for the binomial
parabola;
Packing & Delivery
Honeycomb box packing
Our Advantages
Hot Searches