- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
FanShun
-
Product name:
-
suction accumulator
-
After Warranty Service:
-
No service
-
Local Service Location:
-
None
-
After-sales Service Provided:
-
No after-sales service
-
Marketing Type:
-
Ordinary Product
Quick Details
-
Type:
-
Filter Drier
-
Application:
-
Refrigeration Parts
-
Place of Origin:
-
Zhejiang China
-
Brand Name:
-
FanShun
-
Product name:
-
suction accumulator
-
After Warranty Service:
-
No service
-
Local Service Location:
-
None
-
After-sales Service Provided:
-
No after-sales service
-
Marketing Type:
-
Ordinary Product
Product Paramenters
Product Introduction
In air-conditioning refrigeration system, there’re high pressure and low pressure refrigerant pipes. High pressure refrigerant has high temperature and needs condenser to cooling, and the low pressure refrigerant flow from evaporator needs suction line accumulator to separate gas and liquid, the liquid needs time and temperature to evaporate to gas and then enter compressor, it avoids liquid compression to prolong compressor’s life.
The heat exchange suction accumulator puts two refrigerant pipes together to one vessel, one is high pressure and high temperature and needs cooling, the other is low pressure and low temperature and require to evaporate, so that the two pipes can transfer high and low temperature, let the high temperature refrigerant get cooling and low temperature refrigerant get evaporated. The system’s efficiency will be promoted greatly and cooling effect get better after the heat exchange.
Feature
1.”U“ tube design for maximum flow of refrigerant and minimum oil entrapment
2.Compatible with HFC, HCFC,CFC and associated oils and additives.
3.If the refrigeration system’s evaporation temperature below-15℃,we
Recommends to assemble one heat exchanger
4.Maximum working pressure:3.0Mpa
In air-conditioning refrigeration system, there’re high pressure and low pressure refrigerant pipes. High pressure refrigerant has high temperature and needs condenser to cooling, and the low pressure refrigerant flow from evaporator needs suction line accumulator to separate gas and liquid, the liquid needs time and temperature to evaporate to gas and then enter compressor, it avoids liquid compression to prolong compressor’s life.
The heat exchange suction accumulator puts two refrigerant pipes together to one vessel, one is high pressure and high temperature and needs cooling, the other is low pressure and low temperature and require to evaporate, so that the two pipes can transfer high and low temperature, let the high temperature refrigerant get cooling and low temperature refrigerant get evaporated. The system’s efficiency will be promoted greatly and cooling effect get better after the heat exchange.
Feature
1.”U“ tube design for maximum flow of refrigerant and minimum oil entrapment
2.Compatible with HFC, HCFC,CFC and associated oils and additives.
3.If the refrigeration system’s evaporation temperature below-15℃,we
Recommends to assemble one heat exchanger
4.Maximum working pressure:3.0Mpa
Nomenclature: For Example ZRR-2406
ZRR
|
24
|
06
|
Series
|
Model Number
|
Connection Size(in3/4”)
|
Details Images
Product Category
Our Advantages
Hot Searches