- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
FUOOTECH
-
Model Number:
-
SX-150
-
Function:
-
Testing octane and cetane of gasoline and diesel fuel
-
Gasoline octane number range:
-
40 ~ 135 ON
-
Gasoline stability measurement range:
-
50-2400 min.
-
Cetane number measurement range:
-
20 ~ 100
-
Kerosene content determination range:
-
0 ~ 95%
-
Measure time:
-
1 ~ 5 seconds
-
Application:
-
Widely used in Petrol Station, Lab, Oil, Eletrical Station
-
Display:
-
LCD liquid crystal display
-
Dimension:
-
100 * 210 * 40
-
Advantage:
-
Portable type with battery
Quick Details
-
Warranty:
-
1 year
-
Power:
-
Electronic
-
Place of Origin:
-
Chongqing, China
-
Brand Name:
-
FUOOTECH
-
Model Number:
-
SX-150
-
Function:
-
Testing octane and cetane of gasoline and diesel fuel
-
Gasoline octane number range:
-
40 ~ 135 ON
-
Gasoline stability measurement range:
-
50-2400 min.
-
Cetane number measurement range:
-
20 ~ 100
-
Kerosene content determination range:
-
0 ~ 95%
-
Measure time:
-
1 ~ 5 seconds
-
Application:
-
Widely used in Petrol Station, Lab, Oil, Eletrical Station
-
Display:
-
LCD liquid crystal display
-
Dimension:
-
100 * 210 * 40
-
Advantage:
-
Portable type with battery
Product Description
Portable Octane and Cetane Analyzer for Engine Oil and Transformer Oil
Details Images
Specification
Item
|
Unit
|
Value
|
Gasoline octane number range
|
ON
|
40–135
|
Gasoline octane number measurement accuracy
|
ON
|
± 0.5
|
Limit of acceptable difference between parallel octane number measurements, max
|
ON
|
± 0.2
|
Gasoline stability measurement range
Petrol oxidation breakdown time measurement range |
min.
|
50-2400
|
Acceptable limit of gasoline oxidation breakdown time basic error
|
%
|
5
|
Acceptable basic error limit of petrol oxidation breakdown time
|
min.
|
10
|
Cetane number measurement range
|
CN
|
20–100
|
Measurement accuracy of diesel cetane number
|
CN
|
±1.0
|
Acceptable difference limit between cetane numbers parallel measurements, max
|
CN
|
±0.5
|
Acceptable error limit when determining diesel fuel pour point
|
Co
|
± 5
|
Kerosene content determination range in diesel fuels
|
%
|
0-95
|
Acceptable basic error limit when determining kerosene content in diesel fuels
|
%
|
3
|
Measure time
|
sec.
|
1–5
|
Minimum power supply for instrument operation
|
V
|
5.4
|
Instrument service life
|
MIN. years
|
6
|
Overall dimensions of:
|
|
|
Electronic unit
|
mm
|
100х210х40
|
Sensor
|
mm
|
60х100
|
Instrument weight (including 1 sensor)
|
g
|
850
|
The instrument capabilities:
Parameter
|
Description
|
Standards
|
Measurement of gasoline octane level
|
Research (RON), motor (MON) method. Anti Knocking Index AKI (Pump octane number PON).
|
GOST 8226-82 (ASTM D 2699-86), GOST 511-82 (ASTM D 2700-86), GOST Р 51105-97, GOST Р 51866-2002 (ЕН 228-99)
|
Measurement of diesel cetane level
|
In addition to cetane number, the diesel type and pour point are defined.
|
GOST 305-82 (ASTM D 4737-03), GOST 3122-67 (ASTM D 613, EN ISO 5165)
|
Measurement of diesel fuel pour point
|
It is determined depending on the diesel fuel cetane number.
|
Informative parameter
|
Determination of diesel fuel type
|
Diesel fuel type (S-summer, W-winter, and A-arctic) is determined depending on the pour point.
|
Informative parameter
|
Kerosene content in diesel fuel
|
Kerosene content in diesel fuel is determined as percentage.
|
Informative parameter
|
Gasoline breakdown time (oxidation stability)
|
Breakdown time is measured in minutes with prior selection of a gasoline grade.
|
GOST 4039-88 (ASTM D 525), GOST Р 52068-2003
|
On-Site Project
Packing & Delivery
Delivery package:
Hot Searches