- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
vowish Visual Field Perimeter, VOWISH
-
Model Number:
-
APS-T90
-
Product name:
-
Visual Field Perimeter
-
Model:
-
APS-T90
-
Function:
-
Optical Examination
-
Detection method:
-
Static perimetry
-
Certificate:
-
CE ISO
-
Type:
-
Manufacturer
-
Detection range:
-
0-90
-
Location:
-
Shanghai
Quick Details
-
Warranty:
-
12 months, 12 month
-
Customized support:
-
No
-
Place of Origin:
-
Shanghai, China
-
Brand Name:
-
vowish Visual Field Perimeter, VOWISH
-
Model Number:
-
APS-T90
-
Product name:
-
Visual Field Perimeter
-
Model:
-
APS-T90
-
Function:
-
Optical Examination
-
Detection method:
-
Static perimetry
-
Certificate:
-
CE ISO
-
Type:
-
Manufacturer
-
Detection range:
-
0-90
-
Location:
-
Shanghai
ophthalmology perimeter APS-T90 ophthalmic visual field perimeter machine
APS-T90 Visual Field Perimeter
Features:
Parameters:
Technical Specification |
|
Model |
APS-T90 |
Stimulate point appearing way |
Optical projection |
Detection method |
Static perimetry |
Detection range |
0-90 degree |
Background light |
Yellow, white |
Background brightness |
White : 31.5asb Yellow : 315asb |
Visual Target Color |
Red , blue, white |
Visual Target Brightness |
0.08asb-10000asb |
Vision Target Interval time |
≥200ms ( customizable , no limit ) |
Visual target holding time |
≥200ms ( customizable , no limit ) |
Brightness level |
0-51db |
Visual Target Size
|
Grade Ⅱ Grade Ⅲ Grade Grade Grade |
Detection strategy |
Full-threshold, fast threshold, custom, Two notation, three notation, quantify defects |
Threshold strategy |
Intelligent dynamic, fast intelligent dynamic, age-related, The threshold, a single strength |
Threshold Test Mode |
Center 10-2, Center 24-2, Center 30-2, Center 60-4, Nasal step, macula |
Screening, special test mode |
Center 40, Center 64, Center 76, Center 80, Center Armaly; Peripheral 60, Nasal step, |
|
Armaly Full Field, Full Field 81, Full Field 120;Full Field 135, Full Field 246, upper 36, upper 64, Ester mansinglesee, Ester manbinocular |
Fixation monitoring |
Dynamic real-time video monitoring, physiological blind spot monitoring, Eye tracking curve, eye position offset alarm |
Analysis Software |
Reliability analysis, analysis of a single vision, triple report analyzes, Overview vision analysis, glaucoma semi vision analysis |
Report Figure |
Value, grayscale, the overall bias decibel chart, The overall deviationprobability map, chart pattern deviation decibels, Pattern deviation probability plot, staring Figure |