- Product Details
- {{item.text}}
Quick Details
-
Type:
-
Air Source Heat Pump
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
TX heat pump
-
Model Number:
-
TX heat pump
-
Item:
-
monoblock inverter heat pumps
-
Power supply:
-
220-230V/380-400V~50/60Hz
-
Refrigerant:
-
R32/R290
-
Features 1:
-
super comfortable
-
features 2:
-
super efficicent
-
Features 3:
-
Easy Maintenance
-
Features 4:
-
one stop HVAC solution
-
Function:
-
House Heating Cooling Hot Water
-
Certification:
-
CE Certificate
Quick Details
-
Warranty:
-
1 Year
-
Application:
-
Household
-
Power Source:
-
Electric
-
Type:
-
Air Source Heat Pump
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
TX heat pump
-
Model Number:
-
TX heat pump
-
Item:
-
monoblock inverter heat pumps
-
Power supply:
-
220-230V/380-400V~50/60Hz
-
Refrigerant:
-
R32/R290
-
Features 1:
-
super comfortable
-
features 2:
-
super efficicent
-
Features 3:
-
Easy Maintenance
-
Features 4:
-
one stop HVAC solution
-
Function:
-
House Heating Cooling Hot Water
-
Certification:
-
CE Certificate
Full DC Inverter R290 Air to water floor heating cooling heat pump air source monoblock inverter heat pumps
Product Description
The TX Monoblock heat pump is 3 in 1, with heating, cooling, and hot water all in one.
OutLook
R32 environmental refrigerant Energy class: A+++ Full DC inverter Panasonic compressor and fan motor -25℃ inverter EVI Power Detection Function SG-READY Function 5-Inch TFT True Color Screen 5G/2.4G Compatible WIFI Module Dual Temperature Zone Reserved RS485 Communication Port Linkage Control with PV Function Outlet water temperature up to 60℃ |
Features
R290 refrigerant,low GWP(GWP=3)
Energy class: A+++
Stable operation at -25°C
Outlet water temperature up to 75℃
Power Detection Function
SG-READY Function
5-Inch TFT True Color Screen
5G/2.4G Compatible WIFI Module
Dual Temperature Zone
Reserved RS485 Communication Port
Linkage Control with PV Function
|
Energy Saving | |
|
Full DC Inverter Technology
Full DC inverter twin rotary compressor has smaller size and higher efficiency Variable frequency stepless speed control motor is more energy saving. Introduction of water-cooled canned rotor pump realizes lower sound level and higher efficiency. |
Ten layers of security protection for peace of mind
From refrigerant, water flow to power supply, set up a ten-item all-round safety protection system, all-time and all-round escort, so that the equipment can operate more safely and stably.
|
Specifications:
Model: |
|
BLN-006TB1 |
BLN-010TB1 |
BLN-010TB3 |
BLN-014TB1 |
BLN-014TB3 |
BLN-018TB1 |
|
Power Supply |
|
220~240V~ /50Hz |
220~240V~ /50Hz |
380~415V/3N~ /50Hz |
220~240V~ /50Hz |
380~415V/3N~ /50Hz |
220~240V~ /50Hz |
|
Nominal Heating (Max) (A7/6℃,W30/35℃) |
Heating Capacity |
kW |
2.50 ~ 8.30 |
4.20-12.20 |
4.20 ~ 12.20 |
5.30 ~ 16.50 |
5.30-16.60 |
6.20-20.50 |
Input Power |
kW |
0.57 ~ 1.92 |
0.86 ~ 2.88 |
0.86 ~ 2.88 |
1.15 ~ 4.15 |
1.15 ~ 4.15 |
1.36 ~ 5.28 |
|
Current Input |
A |
2.53 ~ 8.52 |
3.82 ~ 12.77 |
1.46 ~ 4.89 |
5.10 ~ 18.41 |
1.86 ~ 6.70 |
6.10 ~ 23.67 |
|
COP |
W/W |
4.32 ~ 5.86 |
4.23 ~ 5.39 |
4.23 ~ 5.39 |
3.97 ~ 5.43 |
3.97 ~ 5.43 |
3.88 ~ 5.21 |
|
Nominal Heating (Max) (A7/6℃,W47/55℃) |
Heating Capacity |
kW |
2.30 ~ 7.62 |
3.85 ~ 11.20 |
3.85 ~ 11.20 |
4.90 ~ 15.10 |
4.90 ~ 15.10 |
6.30 ~ 19.90 |
Current Input |
kW |
0.75 ~ 2.61 |
1.13 ~ 3.75 |
1.13 ~ 3.75 |
1.65 ~ 5.25 |
1.65 ~ 5.25 |
1.65 ~ 6.82 |
|
Input Current |
A |
3.32 ~ 11.58 |
5.01 ~ 16.6 |
1.92 ~ 6.37 |
7.32 ~ 23.30 |
1.67 ~ 8.47 |
7.40 ~ 30.56 |
|
COP |
W/W |
2.92 ~ 3.33 |
2.99 ~ 3.46 |
2.99 ~ 3.46 |
2.87 ~ 3.38 |
2.87 ~ 3.38 |
2.91 ~ 3.34 |
|
Nominal Cooling (Max) (A35/24℃,W12/7℃) |
Cooling Capacity |
kW |
1.80 ~ 7.10 |
2.60 ~ 10.30 |
2.60 ~ 10.30 |
4.50 ~ 13.50 |
4.50 ~ 13.50 |
5.50 ~ 17.50 |
Current Input |
kW |
0.61 ~ 2.43 |
0.91 ~ 3.65 |
0.91 ~ 3.65 |
1.45 ~ 4.85 |
1.45 ~ 4.85 |
1.65 ~ 6.25 |
|
Input Current |
A |
2.71 ~ 10.78 |
4.03 ~ 16.19 |
1.55 ~ 6.20 |
6.43 ~ 21.52 |
2.34 ~ 7.82 |
7.40 ~ 28.02 |
|
EER |
W/W |
3.04 |
3 |
3.00 |
2.87 |
2.87 |
2.96 |
|
ERP Level(Outlet water temp. at 35℃) |
/ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
|
ERP Level(Outlet water temp. at 55℃) |
/ |
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
|
Rated Input Power |
kW |
2.71 |
3.83 |
3.83 |
6.20 |
6.20 |
7.50 |
|
Rated Input Current |
A |
12 |
17 |
6.5 |
27.50 |
10.50 |
35.00 |
|
Refrigerant Type / Charge / GWP |
/ |
R32/1.25/675 |
R32/1.8/675 |
R32/1.8/675 |
R32/2.8/675 |
R32/2.8/675 |
R32/3.5/675 |
|
Rated water flow |
m3/h |
1.1 |
1.75 |
1.75 |
2.52 |
2.52 |
3.20 |
|
Fan quantity |
/ |
1 |
1 |
1 |
1 |
1 |
2 |
|
Fan motor type |
/ |
DC inverter |
||||||
Compressor |
/ |
Panasonic / DC inverter / Rotary / EVI |
||||||
Circulating pump |
/ |
Inverter type / Built-in |
||||||
IP Class |
/ |
IPX4 |
||||||
Sound pressure at 1m distance |
dB(A) |
49 |
52 |
52 |
53 |
54 |
56 |
|
Max outlet water temperature |
°C |
60 |
60 |
60 |
60 |
60 |
60 |
|
Water piping connections |
inch |
G1 |
G1 |
G1 |
G1-1/4 |
G1-1/4 |
G1-1/2 |
|
Pressure drop at rating water flow |
kPa |
25 |
27 |
27 |
30 |
30 |
32 |
|
Operating temperature range (Heating mode) |
°C |
-25~45 |
||||||
Operating temperature range (Cooing mode) |
°C |
16~45 |
||||||
Unpacked Dimensions ( L×D×H ) |
mm |
1100×445×850 |
1100×445×850 |
1100×445×850 |
1110×480×850 |
1110×480×850 |
1110×445×1450 |
|
Packed Dimensions ( L×D×H ) |
mm |
1160x530x1010 |
1160x530x1010 |
1160x530x1010 |
1160×565×1010 |
1160×565×1010 |
1170×530×1610 |
|
UnPacked Weight |
kg |
102 |
107 |
107 |
124 |
124 |
151 |
|
Packed Weight |
kg |
114 |
119 |
119 |
136 |
136 |
168 |
About Us
Heat pump P roducts Line
Contact Us
Cindy Cui
Sales Manager / International Projects Service Centre
Tongxing Air Conditioning Technology Co., Ltd.(China)
Email: cindycui(@)tongxingac.com
Mobile: 0086 15617912993
R290 Air to water floor heating cooling heat pump air source monoblock inverter heat pumps