Products
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC
Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC

Ion Chromatography Column IC Column C18 RP Na H Ag 1cc Samples Pretreatment SPE Cartridge 1mL SPE Filler For HPLC

FOB Reference Price: Get Latest Price
≥100 Pieces
US $2
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Place of Origin:
Guangdong, China
Filler:
C18, RP, Ag, H, Na, Ag

Quick Details

Warranty:
none
Brand Name:
JVLAB
Model Number:
ION-C18, ION-RP, ION-Ag, ION-H, ION-Ag
Place of Origin:
Guangdong, China
Filler:
C18, RP, Ag, H, Na, Ag
Product Overview

Ion Chromatography P retreatment Column


The pre-treatment column is suitable for solid-phase extraction of analytes and matrix elimination of samples.
Details Images

IC-H pretreatment column

2.7-2.9μeq,1cc.
Use to remove alkaline earth metal ions, transition metal ions and carbonate ions from sample matrix, and is also used to neutralize the strong alkalinity of sample solution.

IC-Na pretreatment column

2.7-2.9μeq,1cc.
Use to remove transition metal ions and alkaline earth metal ions from samples.

IC-Ag pretreatment column

2.7-2.9μeq,1cc.
Use to remove Cl-, Br-, I-, AsO43-, CrO42-, CN-, MoO42-, PO43-, SeO32-, SeCN-, SO32-, S2-, SCN- and WO42- plasma from the sample solution.

IC-RP pretreatment column

400mg,1cc.
Use to remove hydrophobic compounds, especially unsaturated compounds and aromatic compounds, PH range is 0~14.

IC-Ba pre-treatment column

2.7-2.9 μ Eq, 1cc.
Use to remove sulfate ions from the sample.

IC-C18 pretreatment column

400mg,1cc.
Use to removal of hydrophobic compounds pH range 2~8.

Activation and usage steps of pre-treatment columns


IC-C18 & IC-RP Columns 1. Extract 5mL of chromatographic pure methanol using a disposable syringe and push it into a C18 or RP column at a flow rate of 2-4mL/min. 2. Extract 10mL of secondary deionized water using a disposable syringe and push it into a C18 or RP column at a flow rate of 2-4mL/min. 3. Allow C18 or RP small columns to stand flat for 20 minutes to ensure their full activation. 4. Use a disposable syringe to extract the sample solution, push it into a C18 or RP column at a flow rate of 2-4mL/min, and discard the first 3mL. 5. Collect the remaining liquid and combine it with a needle filter to directly enter ion chromatography for analysis, or transfer it to a sample bottle for injection analysis through an automatic sampler. 6. In principle, C18 or RP pre-treatment columns are disposable, but in order to save costs, they can be activated and regenerated for reuse. The method of regeneration is to repeat steps (1) and (2) for regeneration. Generally, one RP column can be regenerated 5 times.

IC-H, IC-Na, IC-Ag, IC-Ag/H Columns 1. Extract 10mL of deionized water with a disposable syringe and push it through the small column at a flow rate of 2-4mL/min. 2. Allow the small column to stand flat for 30 minutes and fully activate it. 3. Use a disposable syringe to extract the sample solution, push it into the small column at a flow rate of 2-4mL/min, and discard the first 3mL. 4. Collect the remaining liquid and combine it with a needle filter to directly enter ion chromatography for analysis, or transfer it to a sample bottle for injection analysis through an automatic sampler.

Attention Please! 1. The H column, Ag column, and Ag/H column are all non renewable. 2. When using Ag columns, they must be combined with H columns for better results. 3. The Ag column and Ag/H column are used to remove chloride ions from the sample solution. When the small column adsorbs chloride ions, the filler portion that adsorbs chloride ions will turn black. When the filler black extends to 2/3 of the solution, it is not recommended to reuse it. Reuse interval: Use a disposable syringe to extract 20mL of deionized water and push it through the small column at a flow rate of 2-4mL/min for cleaning to avoid cross contamination. 4. When activating the cleaning column, it is important to ensure that the liquid is vertically pushed into the column from the syringe and left to stand for 20 minutes.
APP
Post My RFQ
WhatsApp
+86-17326049340