Quick Details
-
Brand Name:
-
QX
-
Model Number:
-
HFS-25 HFS-20 HFS-15 LKB-01
-
Operating Temperature:
-
100 °C
-
operation temperature:
-
0-60
-
material:
-
brass or stainless stell
-
Control Type:
-
Paddle
-
Connection:
-
NPT Pipe Thread
-
Material:
-
Stainless steel or brass
-
Electrical Switch:
-
SPDT RATING :220VAC/15A
-
Case:
-
Plastic cover witch 1/2 couduit opening
Quick Details
-
Media Type:
-
Liquid
-
Flow Rate:
-
1.5-48.5 m3/h
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
QX
-
Model Number:
-
HFS-25 HFS-20 HFS-15 LKB-01
-
Operating Temperature:
-
100 °C
-
operation temperature:
-
0-60
-
material:
-
brass or stainless stell
-
Control Type:
-
Paddle
-
Connection:
-
NPT Pipe Thread
-
Material:
-
Stainless steel or brass
-
Electrical Switch:
-
SPDT RATING :220VAC/15A
-
Case:
-
Plastic cover witch 1/2 couduit opening
Brand Name
|
QX
|
Model Number
|
HFS-25 HFS-20 HFS-15 LKB-01
|
Medium
|
brass or stainless stell
|
pressure
|
1.6Mpa
|
output
|
SPDT
|
IP
|
IP65 |
Operating
|
0 ~ 65
|
size
|
1, 3/4, 1/2
|
Service life
|
>10000times |
Maximum liquid pressure: 1.6 MPa. Available with 3 stainless steel paddles for pipe diameters from 25 to 75 mm. The number of
paddles can be changed on request and the length of the paddles can be trimmed on request.The HFS series liquid flow switches are
supplied with an additional 6'' paddle for use in 100 to 150mm diameter pipes.
Diameter pipes. The flow setting is adjustable and the user can set the flow value as required. For the convenience of the user,
the HFS series flow switches have a large wiring space.The HFS series is also available with stainless steel connections for
ammonia and other media.
Ammonia and other media.
1, 3/4, 1/2'' Fractional Threaded Connections Brass Material Toggle Flow Switches Toggle flow switches are used to detect
unidirectional or bi-directional flow of fluids, including ammonia and other media.
When the fluid flows through the pipe, the baffle plate is deflected, by adjusting the adjusting bolt.
When the fluid flows through the pipeline, the baffle deflects, and by adjusting the adjusting bolt, the single-knife,
double-throw microswitch is actuated at the set flow rate and outputs a switching signal; for bidirectional detection, the baffle
deflects, and the single-knife, double-throw microswitch is actuated at the set flow rate and outputs a switching signal.
signal; for bidirectional detection, the baffle plate deflection pushes the magnetic module up and the module acts. For detecting
one-way flow of air and water.
and water, the water should not be entangled debris. When the fluid flows through the pipe in the indicated direction, the baffle
plate will be deflected.
Deflection. By adjusting the mediator bolt, the single-pole, double-throw microswitch is activated at the set flow rate and
outputs a
switching signal. Set flow range with easy adjustment Widely used for measurement of water, gas, oil and other media.
Translated with DeepL
paddles can be changed on request and the length of the paddles can be trimmed on request.The HFS series liquid flow switches are
supplied with an additional 6'' paddle for use in 100 to 150mm diameter pipes.
Diameter pipes. The flow setting is adjustable and the user can set the flow value as required. For the convenience of the user,
the HFS series flow switches have a large wiring space.The HFS series is also available with stainless steel connections for
ammonia and other media.
Ammonia and other media.
1, 3/4, 1/2'' Fractional Threaded Connections Brass Material Toggle Flow Switches Toggle flow switches are used to detect
unidirectional or bi-directional flow of fluids, including ammonia and other media.
When the fluid flows through the pipe, the baffle plate is deflected, by adjusting the adjusting bolt.
When the fluid flows through the pipeline, the baffle deflects, and by adjusting the adjusting bolt, the single-knife,
double-throw microswitch is actuated at the set flow rate and outputs a switching signal; for bidirectional detection, the baffle
deflects, and the single-knife, double-throw microswitch is actuated at the set flow rate and outputs a switching signal.
signal; for bidirectional detection, the baffle plate deflection pushes the magnetic module up and the module acts. For detecting
one-way flow of air and water.
and water, the water should not be entangled debris. When the fluid flows through the pipe in the indicated direction, the baffle
plate will be deflected.
Deflection. By adjusting the mediator bolt, the single-pole, double-throw microswitch is activated at the set flow rate and
outputs a
switching signal. Set flow range with easy adjustment Widely used for measurement of water, gas, oil and other media.
Translated with DeepL
FAQ
1. Can provide OEM manufacturing: products, packaging
2. Sample orders available
3.We will respond to your inquiry within 24 hours.
4.After sending, we will track the product for you every three days until you receive it. When you receive the products, test them and give me feedback. If you have any questions about the issue, please contact our customer service and we will provide you with a professional solution.