Solar power station systems are typically used for regional centralized power supply, such as village, island, fields monitoring
and so on. Also the power level range is between kilowatts to hundreds kilowatts.
Explore More Products
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
Sunpal
-
Work Time (h):
-
Depend On Sun Duration
-
Max PV Power:
-
56.8KW
-
Max PV Voltage:
-
480V
-
Certificate:
-
ce
-
Warranty:
-
3years
-
System nominal voltage:
-
48/96/192/220/240VDC
-
Battery voltage range:
-
48-240V
-
Cooling:
-
Forced air cooling
-
Communication(Optional):
-
RS485
-
Display:
-
LCD+LED
-
Noise(dB,1m):
-
<55
-
Working Temperature(°C):
-
-10~+50
-
Ralative Humidity:
-
0-95%(Non-condensing)
-
Altitude(m):
-
<5000
-
Degree of Protection:
-
IP20
Quick Details
-
Type:
-
MPPT
-
Application:
-
Solar Working Station, Solar System Controller
-
Place of Origin:
-
China
-
Brand Name:
-
Sunpal
-
Work Time (h):
-
Depend On Sun Duration
-
Max PV Power:
-
56.8KW
-
Max PV Voltage:
-
480V
-
Certificate:
-
ce
-
Warranty:
-
3years
-
System nominal voltage:
-
48/96/192/220/240VDC
-
Battery voltage range:
-
48-240V
-
Cooling:
-
Forced air cooling
-
Communication(Optional):
-
RS485
-
Display:
-
LCD+LED
-
Noise(dB,1m):
-
<55
-
Working Temperature(°C):
-
-10~+50
-
Ralative Humidity:
-
0-95%(Non-condensing)
-
Altitude(m):
-
<5000
-
Degree of Protection:
-
IP20
Product Description
Parameters
Model
|
GSM48
|
GSM96
|
GSM192
|
GSM220
|
GSM240
|
|||||
Rated Current (A)
|
60/120
|
50/100/150/200
|
|
|
|
|||||
Battery Input
|
|
|
|
|
|
|||||
Rated voltage (VDC)
|
48
|
96
|
192
|
220
|
240
|
|||||
Low voltage protection point (VDC)
|
43.2
|
86.4
|
172.8
|
194.4
|
216.0
|
|||||
Low voltage recovery point (VDC)
|
52.0
|
104.0
|
208.0
|
23.40
|
260.0
|
|||||
Over voltage protection point (VDC)
|
62.0
|
124.0
|
248.0
|
279.0
|
310.0
|
|||||
Over voltage recovery point (VDC)
|
60.0
|
120.0
|
240.0
|
270.0
|
300.0
|
|||||
Soalr Input
|
|
|
|
|
|
|||||
Charging Mode
|
Three-stage:constant current(MPPT)、constant voltage、float
|
|
|
|
|
|||||
Maximum input power(kWp)
|
3.4/6.8
|
5.7/11.4/17.1/22.8
|
11.4/22.8/34.2/45.6
|
12.8/25.6/38.4/51.2
|
14.2/28.4/42.6/56.8
|
|||||
Starting voltage (VDC)
|
60
|
120
|
240
|
270
|
300
|
|||||
MPPT Voltage Range(VDC)
|
50-150
|
110-280
|
230-450
|
260-450
|
290-450
|
|||||
Max. Open Circuit Voltage(VDC)
|
170
|
300
|
480
|
480
|
480
|
|||||
Maximum Efficiency
|
>98%
|
|
|
|
|
|||||
MPPT Efficiency
|
>99%
|
|
|
|
|
|||||
Other
|
|
|
|
|
|
|||||
Noise (dB)
|
<55
|
|
|
|
|
|||||
Ralative Humidity
|
0-95%(Non-condensing)
|
|
|
|
|
|||||
Display
|
LCD+LED
|
|
|
|
|
|||||
Communication(Optional)
|
RS485
|
|
|
|
|
|||||
Working Temperature(°C)
|
-10~+50
|
|
|
|
|
|||||
Cooling
|
Forced air cooling
|
|
|
|
|
|||||
Altitude(m)
|
<5000
|
|
|
|
|
|||||
Degree of Protection
|
IP20
|
|
|
|
|
|||||
Dimension(D x W x H)(mm)
|
160 x 400 x 280 / 440 x 440 x 685
|
|
|
|
|
|||||
Weight(kg)
|
7-8 / 10-40
|
|
|
|
|
|||||
Protections
|
PV array reverse polarity protection;night time anti-charge protection; battery overcharge protection,over-discharge protection;
output overload protection; output short circuit protection |
|
|
|
|
Configuration
Details Images & Packing
Our Projects
Our Factory
Application
Solar Station System
Solar Home System
Solar home system are typically used for home photovoltaic power generation system, to solve electricity demand of none power or
unstable power region. Also the power level rage is between hundred watts to kilowatts.
unstable power region. Also the power level rage is between hundred watts to kilowatts.
Solar RVs/Vessels System
Solar RVs/Vessels system are typically used for reducing the RVs and the vessels electricity cost, by setting up solar system to
assist gasoline/diesel power generator.
assist gasoline/diesel power generator.
Solar Street lights System
Solar Street lights System are typically used for street lightning of cities, villages, the intelligent streetlight system will
remote monitoring all street lamps to reduce the operation and maintenance costs of system.
remote monitoring all street lamps to reduce the operation and maintenance costs of system.
Hybrid Energy System
The Hybrid energy system contains solar, wind, diesel and city electricity energy system. The system will meet the load demand of
electricity in villages, islands, and telecom stations to reduce the system cost and improve the replenishment ratio of system.
electricity in villages, islands, and telecom stations to reduce the system cost and improve the replenishment ratio of system.
Certifications
Hot Searches