- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
ACD190-4T2.2GB
-
Output Frequency:
-
0-500Hz
-
Size:
-
23*11*17cm
-
Weight:
-
1.5KG
-
Application:
-
Motor
-
Certificate:
-
CE ISO9001, CE,ISO9001
-
Warranty:
-
12 Months
-
Protection:
-
Overload
-
Color:
-
Black
-
Inverter type:
-
Ac -Dc-Ac Frequency Inverter
-
OEM:
-
Accept OEM Logo
-
Frequency:
-
50/60 HZ
-
Control mode:
-
SVC V/F Control
Quick Details
-
Output Current:
-
5.0A
-
Place of Origin:
-
Shandong, China
-
Brand Name:
-
K&R Technology
-
Model Number:
-
ACD190-4T2.2GB
-
Output Frequency:
-
0-500Hz
-
Size:
-
23*11*17cm
-
Weight:
-
1.5KG
-
Application:
-
Motor
-
Certificate:
-
CE ISO9001, CE,ISO9001
-
Warranty:
-
12 Months
-
Protection:
-
Overload
-
Color:
-
Black
-
Inverter type:
-
Ac -Dc-Ac Frequency Inverter
-
OEM:
-
Accept OEM Logo
-
Frequency:
-
50/60 HZ
-
Control mode:
-
SVC V/F Control
Product Display
Parameters
Input
|
Rated voltage . frequency
|
Three phase AC380V:50/60Hz
Single phase AC220V:50V60Hz |
|
||
|
Allowable range of voltagevariation
|
Three phase AC360V-450V
Single phase AC190V - 250V |
|
||
Output
|
Voltage
|
0-460V :0-260V
|
|
||
|
Frequency
|
low-frequency mode : 0- 300Hz High-frequency mode : 0-3000Hz
|
|
||
|
Overload capacity
|
G Model:110% long term 150% 1 min 200% 4 second
P Model:105% Long term 120%1 min 150%1 second |
|
||
Control Model
|
|
V/F control, advanced V/F control, V/F separation control, PG free current vector control
|
|
||
Control Characteri stics
|
Frequency setting resolution
|
Analog input
|
0.1% of maxximum output frequency
|
||
|
|
Digital settings
|
0.01Hz
|
||
|
Frequency accuracy
|
Analog input
|
Within 0.2% of the maxirum outout frequency
|
||
|
|
Digital input
|
Set output frequency within 0.01%
|
||
|
V/F control
|
V/F curve
|
The reference frequency can be set arbitrarily from 0.5 to 3000Hz, and the multi-point V/F curve can beset arbitrarily. Multiple fixed curves such as constant torque, reduced torque 1, reduced torque 2, andsquared torque can also be selected
|
||
|
|
Torque boost
|
Manual setting: 0.0~30.0% of rated output
Automatic lifting: Automatically determine the lifting torque based on the output current and combined with motor parameters |
||
|
|
Automatic current and voltage limiting
|
It can automatically detect the stator current and voltage of the motor during acceleration, deceleration,or stable operation, and suppress them within the allowable range based on a unique algorithm.minimizing the possibility of system fault tripping
|
||
Control Characteri stics
|
Inductive vector control
|
Voltage frequencycharacteristics
|
Automatically adjust the output voltage frequency ratio based on motor parameters and unique algorithms
|
||
|
|
Torque characteristic
|
Starting torque:
150% rated torque at 3.0Hz (V/F control) 150% rated torque at 1.0Hz (advanced V/F control) 150% rated torque at 0.5Hz (without PG current vector control) Steady state accuracy of operating speed: s 0.2% of rated synchronous speed Speed fluctuation: ≤ 0.5% rated synchronous speed Torque response: ≤ 20ms (without PG current vector control) |
||
|
|
Self measurement ofmotor carmeters
|
Without any limitations, automatic parameter detection can be completed under both static and dynamic
conditions of the motor to achieve the best control effect |
||
|
|
Current and voltage suppression
|
Full process current closed-loop control, completely avoiding current impact, with complete overcurrent and overvoltage suppression function
|
||
|
Running Under voltage suppression
|
Especially for users with low grid voltage and frequent fluctuations in grid volage, even within the allowable voltage range, the system can maintain the longest possible operating time based on unique algorithms and residual energy allocation strategies
|
|
||
Typical
functions |
Multi speed swing and operation
|
16 segment programmablemulti segment speedcontrolwith multiple operating modes available.Swing frequency operation:preset freguency and center frequencv adiustable. state memory and recovery after power outage
|
|
||
|
PID control
RS48 communication |
Built-in PID controller (with preset freauency) with standard RS485 communication function, multiple communication protocols
available. and linkage svnchronization control function |
|
||
|
Frequency setting
|
Analog input
|
DC voltage 0-10V, DC current 0-20mA (upper and lower limits optional)
|
||
|
Output signal
|
Digital input
|
settings with analog inputs
Operation panel settings,RS485 interface settings, UP/DW terminal control, and multiple combination |
||
|
|
Digital Output
|
One Y-terminal open collector output and two programmable relay outputs (TA, TB, TC), with up to 61
meaning options |
||
|
|
Analog Output
|
1 channel analog signal output, with a flexible output range between 0-2mA or 0-10V, which can achieve
the output of physical quantities such as set frequency and output frequency |
||
|
Automatic
voltage stabilization operation |
According to needs, dynamic voltage regulation, static voltage regulation, and non votage regulation can be selected to achieve the most stable operating effect
|
|
||
|
Acceleration
and deceleration time setting |
0.1s~3600.0min continuously settable, S-type and linear mode optional
|
|
||
|
Brake
|
energy
consumption braking |
The starting voltage, return voltage, and energy consumption braking rate of energy consumption braking can be continuously adjusted
|
||
|
|
direct current
braking |
Starting frequency of DC braking during shutdown: 0.00- [ F00.13 ] Upper limit frequency
Braking time: 0.0-100.0 seconds; Braking current: 0.0%-150.0% of rated current |
||
|
|
Flux braking
|
0-100 0:Invalid
|
||
|
Low noise operation
|
The carrier frequency is continuously adjustable from 1.0KHz to 16.0KHz, minimizing motor noise
|
|
||
|
Speedtrackingspeed
restart function |
It can achieve smooth restart and instant stop restart functions of the motor in operation
|
|
||
|
Counter
|
One internal counter for easy system integration
|
|
||
|
Operation function
|
Upper and lower frequency settings, frequency jump operation, reverse operation limit, slip frequency compensation,RS485 communication, frequency increase and decrease control, fault self recovery operation, etc
|
|
Product Details
Product Application
Products Category
Hot Searches