3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive
3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive
3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive
3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive
3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive
3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive
3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive
3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive

3 Phase Power Frequency Converter 60Hz 50Hz Frequency Inverter Tower Crane 2.2Kw Delta Variable Frequency Drive

FOB Reference Price: Get Latest Price
≥5 Pieces
US $99
≥50 Pieces
US $56
≥101 Pieces
US $52
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
ACD190-4T2.2GB
Output Frequency:
0-500Hz
Size:
23*11*17cm
Weight:
1.5KG
Application:
Motor
Certificate:
CE ISO9001, CE,ISO9001
Warranty:
12 Months
Protection:
Overload
Color:
Black
Inverter type:
Ac -Dc-Ac Frequency Inverter
OEM:
Accept OEM Logo
Frequency:
50/60 HZ
Control mode:
SVC V/F Control

Quick Details

Output Current:
5.0A
Place of Origin:
Shandong, China
Brand Name:
K&R Technology
Model Number:
ACD190-4T2.2GB
Output Frequency:
0-500Hz
Size:
23*11*17cm
Weight:
1.5KG
Application:
Motor
Certificate:
CE ISO9001, CE,ISO9001
Warranty:
12 Months
Protection:
Overload
Color:
Black
Inverter type:
Ac -Dc-Ac Frequency Inverter
OEM:
Accept OEM Logo
Frequency:
50/60 HZ
Control mode:
SVC V/F Control
Product Display
Parameters
Input
Rated voltage . frequency
Three phase AC380V:50/60Hz
Single phase AC220V:50V60Hz
Allowable range of voltagevariation
Three phase AC360V-450V
Single phase AC190V - 250V
Output
Voltage
0-460V :0-260V
Frequency
low-frequency mode : 0- 300Hz High-frequency mode : 0-3000Hz
Overload capacity
G Model:110% long term 150% 1 min 200% 4 second
P Model:105% Long term 120%1 min 150%1 second
Control Model
V/F control, advanced V/F control, V/F separation control, PG free current vector control
Control Characteri stics
Frequency setting resolution
Analog input
0.1% of maxximum output frequency
Digital settings
0.01Hz
Frequency accuracy
Analog input
Within 0.2% of the maxirum outout frequency
Digital input
Set output frequency within 0.01%
V/F control
V/F curve
The reference frequency can be set arbitrarily from 0.5 to 3000Hz, and the multi-point V/F curve can beset arbitrarily. Multiple fixed curves such as constant torque, reduced torque 1, reduced torque 2, andsquared torque can also be selected
Torque boost
Manual setting: 0.0~30.0% of rated output
Automatic lifting: Automatically determine the lifting torque based on the output current and combined with motor parameters
Automatic current and voltage limiting
It can automatically detect the stator current and voltage of the motor during acceleration, deceleration,or stable operation, and suppress them within the allowable range based on a unique algorithm.minimizing the possibility of system fault tripping
Control Characteri stics
Inductive vector control
Voltage frequencycharacteristics
Automatically adjust the output voltage frequency ratio based on motor parameters and unique algorithms
Torque characteristic
Starting torque:
150% rated torque at 3.0Hz (V/F control)
150% rated torque at 1.0Hz (advanced V/F control)
150% rated torque at 0.5Hz (without PG current vector control)
Steady state accuracy of operating speed: s 0.2% of rated synchronous speed
Speed fluctuation: ≤ 0.5% rated synchronous speed
Torque response: ≤ 20ms (without PG current vector control)
Self measurement ofmotor carmeters
Without any limitations, automatic parameter detection can be completed under both static and dynamic
conditions of the motor to achieve the best control effect
Current and voltage suppression
Full process current closed-loop control, completely avoiding current impact, with complete overcurrent and overvoltage suppression function
Running Under voltage suppression
Especially for users with low grid voltage and frequent fluctuations in grid volage, even within the allowable voltage range, the system can maintain the longest possible operating time based on unique algorithms and residual energy allocation strategies
Typical
functions
Multi speed swing and operation
16 segment programmablemulti segment speedcontrolwith multiple operating modes available.Swing frequency operation:preset freguency and center frequencv adiustable. state memory and recovery after power outage
PID control
RS48 communication
Built-in PID controller (with preset freauency) with standard RS485 communication function, multiple communication protocols
available. and linkage svnchronization control function
Frequency setting
Analog input
DC voltage 0-10V, DC current 0-20mA (upper and lower limits optional)
Output signal
Digital input
settings with analog inputs
Operation panel settings,RS485 interface settings, UP/DW terminal control, and multiple combination
Digital Output
One Y-terminal open collector output and two programmable relay outputs (TA, TB, TC), with up to 61
meaning options
Analog Output
1 channel analog signal output, with a flexible output range between 0-2mA or 0-10V, which can achieve
the output of physical quantities such as set frequency and output frequency
Automatic
voltage
stabilization operation
According to needs, dynamic voltage regulation, static voltage regulation, and non votage regulation can be selected to achieve the most stable operating effect
Acceleration
and
deceleration time setting
0.1s~3600.0min continuously settable, S-type and linear mode optional
Brake
energy
consumption
braking
The starting voltage, return voltage, and energy consumption braking rate of energy consumption braking can be continuously adjusted
direct current
braking
Starting frequency of DC braking during shutdown: 0.00- [ F00.13 ] Upper limit frequency
Braking time: 0.0-100.0 seconds; Braking current: 0.0%-150.0% of rated current
Flux braking
0-100 0:Invalid
Low noise operation
The carrier frequency is continuously adjustable from 1.0KHz to 16.0KHz, minimizing motor noise
Speedtrackingspeed
restart function
It can achieve smooth restart and instant stop restart functions of the motor in operation
Counter
One internal counter for easy system integration
Operation function
Upper and lower frequency settings, frequency jump operation, reverse operation limit, slip frequency compensation,RS485 communication, frequency increase and decrease control, fault self recovery operation, etc
Product Details
Product Application
Products Category
APP
Post My RFQ
WhatsApp
+86-17326049340