Products
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module

Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module

FOB Reference Price: Get Latest Price
≥1 Pieces
US $20.58
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
programmable Multi-channel timing controller
Working voltage:
DC7 to 30V/200V AC
Relay ways:
4/6/8/10/16 ways
Control current:
5A
Working signal:
Switch/NPN Low Power Level
Time delay range:
0.01 to 999 minutes
Output signal:
Relay switch signal
Working life:
≥100,000 times
Application:
LED light strip/water pump/motor

Quick Details

Contact Load:
Low Power
Place of Origin:
Guangdong, China
Brand Name:
Taidacent
Model Number:
programmable Multi-channel timing controller
Working voltage:
DC7 to 30V/200V AC
Relay ways:
4/6/8/10/16 ways
Control current:
5A
Working signal:
Switch/NPN Low Power Level
Time delay range:
0.01 to 999 minutes
Output signal:
Relay switch signal
Working life:
≥100,000 times
Application:
LED light strip/water pump/motor
Taidacent 5V/12V/24V/220V 4/6/8/10/16 CH PLC Programmable Timer Relay Self-Locking Delay Cycle Multi Function Time Relay Module
Product Description
Add lightning protection, anti-surge, voltage suppression protection functions to make product performance more stable.
Specification
item
value
Working voltage
DC7 to 30V/200V AC
Relay ways
4/6/8/10/16 ways
Control current
5A
Working signal
Switch/NPN Low Power Level
Time delay range
0.01 to 999 minutes
Output signal
Relay switch signal
Working life
≥100,000 times
Application
LED light strip/water pump/motor

Function

★P-1 jog: (the signal is pulled in, the signal disappears and disconnected) The multiple channels do not affect each other and are independent of each other. ★P-2 self-locking: (give a signal to pull in, and give a signal to stop) multiple channels do not affect each other and are independent of each other. ★P-3 interlock: (the signal relay is pulled in, the other relays are stopped) and the signal relay is stopped again, and only one channel can work at the same time. ★P-4 Interlock 2: When there are other outputs, it cannot output itself, and only when other outputs are disconnected, it locks itself. P-5: Give a signal, the corresponding relay will automatically stop at time A, and the signal will be invalid during the delay period, and only one channel is working at the same time. ★P-6: Give the signal, the corresponding relay work time A will automatically stop, and the signal will be re-timed during the delay period, and only one channel is working at the same time. P-7: Give the signal, the corresponding relay will automatically stop at time A, reset the signal during the delay period, and only one channel is working at the same time. ★P-8: Give the signal, the corresponding relay will automatically stop at time A, the signal will be invalid during the delay period, and each channel will not affect each other; at the same time, multiple channels can be working. P-9: Give the signal, the corresponding relay work time A will automatically stop, and the signal will be re-timed during the delay period, and each channel will not affect each other; at the same time, multiple channels can be working. P-10: Give the signal, the corresponding relay will automatically stop at time A, reset the signal during the delay period, and each channel will not affect each other; at the same time, multiple channels can be working. ★P-11: Give signal 1, 1-16 sequence delay A time to start, give signal 2, 1-16 sequence delay B time to stop, give signal 3, reset. ★P-12: Give signal 1, 1-16 a sequential delay of time A, work time B, cycle C times to stop, and signal 3 to reset. ★P-13: Give signal 1, 1-16 a sequential delay of time A, work time B, infinite loop, reset signal 3. ★P-14: (give any continuous signal) 1-16 work one after another, (continuous signal disappears) 16-1 stop one after another. ★P-15: For the first signal 1, relay 1 works for A time, for the second signal 1, relay 2 works for A time, for the first signal 1, relay 3 works.......(In this way and so on), the trigger is invalid during the delay period. ★P-16: For the first signal 1, the relay 1 keeps working, for the second signal 1, the relay 2 keeps working, for the third signal 1, the relay 3 keeps working.......(This way and so on), signal 3 is reset. ★P-17: Give any continuous signal, relay 1 starts (signal disconnection, output stop) to the second continuous signal, relay 2 starts (signal disconnection, output stop).......(Multi-channel with so on and so forth) ★P-18: Give any signal, relay 1 starts A time, give the second signal, relay 2 starts A time (multiple channels and so on) ★P-19: Give signal 1, start 1 channel randomly. For signal 2, start one channel every time A, and fix it after time C. For signal 3, the random time is less than the range of AB, and B is greater than A, take the time unit of A, output the random channel, and then stop the signal. Give signal 4 to stop.

Button setting instructions

The power-on display "----" means entering the standby state. Function settings:
Long press the setting button (2 seconds) to enter the function setting, the digital tube displays: P-several: then short press the "+"/"-" button to adjust the function, and then press the setting button to confirm → then enter the adjustment time → short press " +"/"-" to adjust the time unit value (in addition, short press the fourth setting key to adjust the decimal point of the time value, after the adjustment is completed, press the setting key to confirm → the screen displays 000.0, which means entering the standby state.
Decimal point time unit description: XX.X The decimal point is in the ten's place, the timing range: 0.1 seconds to 99.9 seconds, XXX has no decimal point, the timing range: 1 second to 999 seconds, XXX. The decimal point is in the one's place, the timing range: 1 minute to 999 minutes