- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
Sonka
-
Model Number:
-
SK-E500
-
Product name:
-
telemedicine equipment
-
Application:
-
Health Center
-
Function:
-
Detecting Body Health
-
Usage:
-
Body Health Care
-
Display:
-
LCD Touch Screen
-
Keywords:
-
Health Clinical Diagnosis
-
Type:
-
Clinical Examination Aids
-
Item:
-
Body Health Analyzing Machine
-
Size:
-
112*82*124cm
-
Weight:
-
50KG
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Online technical support
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Sonka
-
Model Number:
-
SK-E500
-
Product name:
-
telemedicine equipment
-
Application:
-
Health Center
-
Function:
-
Detecting Body Health
-
Usage:
-
Body Health Care
-
Display:
-
LCD Touch Screen
-
Keywords:
-
Health Clinical Diagnosis
-
Type:
-
Clinical Examination Aids
-
Item:
-
Body Health Analyzing Machine
-
Size:
-
112*82*124cm
-
Weight:
-
50KG
3 In 1 Blood Glucose Cholesterol Uric Acid Testing Device Medical Analysers Health Analyzer Machine
FQA
1.What is BMI?
Body Mass Index (BMI) is a simple calculation using a person’s height and weight. The formula is BMI equals to kg/m2 , the kg is his weight in kilograms, and m2 is his height in metres squared.
A BMI of 25.0 or more is overweight, while the healthy range is 18.5 to 24.9. BMI applies to most adults 18-65 years.
2.What is body composition?
Body composition is a method of breaking down the body into its core components: fat, protein, minerals, and body water. It describes your weight more accurately and provides a better glimpse into your overall health than traditional methods.
Body composition analysis can accurately show changes in fat mass, muscle mass, and body fat percentage.
3. Is your health data accurate?
Yes, the data is correct. Each of the measurement equipment provides a
clinical evaluation report, which approves all the results that are seriously
tested by an authorized laboratory and compare with industry branding.
4.Why is body composition important to measure?
Body composition describes the amount of fat, bone, water, and muscle in the body. Measuring your body composition will tell you your own body’s unique makeup and help you identify areas to work on to improve your overall health and wellness.
5.Why do you need to understand your weight in terms of muscle and fat?
If you only focus on losing weight, you may end up losing muscle mass and eventually sabotage your efforts. By differentiating between muscle and fat, body composition removes the guesswork of determining what your weight fluctuations mean,
6.What is the principle to test body composition?
Based on the new DXA statistic method, the BIA bioimpedance detection technology, which is used both at home and abroad, is adopted by the human body composition analyzer to measure the body composition: body fat, body weight, BMI (body mass index), non-fat mass and other health indexes, so as to effectively indicate the human body health status
7.What are the benefits of body composition?
Calculate your caloric, Assess your Percent Body Fat,Maximize your workout routine to fit your unique health,
8.How Health Kiosk Help Public Health?
Many Health care companies provide telemedicine eHealth APP, which helps people to have health checkup results traceable and see a doctor on the internet. Health checkup kiosks could be located everywhere for the conveniences of the public
9.Can you offer API and SDK?
Yes, customized language.
10.How long is the Warranty?
One year and endless online technical support.
11.Do you have certificates?
Yes, professional CE certificates.
12.Do you have MOQ?
No, You can order one sample for testing quality, factory price.
13.How about the shipment?
The machine will be shipped within 2-3 days after the receipt of your payment. we work with professional cost-effetive freight forwarder parner and get a big shipping discount.
14.How long is the lead time?
General production dates finished within one week without customized request
15.How to make sure of the quality guarantee?
All of our machines need to pass safty test and tighten inspection, take hight temperature test for 4 hours in burn-in room before shipment.
Module Number
|
SK-E500(SONKA Medical)
|
|
|
Dimensions
|
Package dimensions: 480*360*220mm
|
|
|
|
Gross weight:8.2kg Net weight:4.8kg
|
|
|
Category
|
Descriptions
|
Parameters
|
|
Identification login
|
Login methods
|
Any type of reader can be integrated,this is customized modification
|
|
Psychological evaluation
|
Customized function
|
Symptom checking list 90 questionnaire list with evaluation report
|
|
Vision, teeth, WHR
|
|
Manual input results, could be customized
|
|
Height & Weight Scale
|
Module number
|
Need to connect with L08 Height weight scale
|
|
|
Probe type
|
Ultrasonic probe
|
|
|
Height range
|
70.0~210cm
|
|
|
Weight range
|
5~200kg
|
|
|
Weight accuracy
|
±0.1kg
|
|
|
Height accuracy
|
±0.5cm
|
|
Blood pressure unit
|
Range
|
Pressure: 0-299mmHg/0-39.9Kpa
|
|
|
|
Pulse: 40 -180 times/min
|
|
|
accuracy
|
Pressure: < ±3mmHg(±0.5Kpd),Pulse: ±5%
|
|
|
Working temperature & humidity
|
+10℃~+40℃, 30%RH~85%RH
|
|
|
Transportation/Storage temperature & humidity
|
-20℃~+55℃, <93%RH
|
|
|
Operating atmospheric pressure
|
80kpa~106kpa
|
|
|
Cuff circumstance
|
15cm~42cm
|
|
|
Power supply
|
From control board
|
|
Blood oxygen probe
|
Sensor
|
Dual-wavelength LED
|
|
|
Wave length
|
Glow: 663nm Infrared: 890nm
|
|
|
Range
|
35%-100%
|
|
|
Max. Light output power
|
<2mW
|
|
|
Accuracy
|
Difference at ±2% within 70%-100%
|
|
|
Pulse rate error
|
30-250bpm, error is ±2bpm or ±2%, take bigger value
|
|
|
Working temperature
|
5℃-40℃
|
|
|
Relative humidity
|
15%-95%(non condensation)
|
|
|
Atmosphere pressure
|
70kpa-106kpa
|
|
|
Power supply
|
From control board
|
|
Forehead infrared radiation thermometer
|
Test method
|
Infrared wireless hand-held temperature gun
|
|
|
Accuracy
|
0.1 ℃
|
|
|
Operation & storage temperature
|
10~40℃, 0~50℃
|
|
|
Operation & storage humidity
|
≤85%
|
|
|
Power supply
|
From control board
|
|
|
Dimension
|
150*75*40mm
|
|
|
Weight
|
180g
|
|
|
Human temperature range
|
32.0~42.5℃
|
|
|
Accuracy
|
≤±0.3℃
|
|
|
Power consumption
|
≤120mw
|
|
|
Detection distance
|
5 to 8 cm
|
|
|
Auto-off
|
after 8 seconds
|
|
Blood glucose, uric acid, total cholesterol analyzer
|
Specimen
|
Finger tip capillary whole blood
|
|
|
Specimen voulumn
|
Blood glucose: 0.9uL, Total cholesterol: 10uL, Uric acid: 1uL
|
|
|
Measurement period
|
10s (Blood glucose), 26s(Cholesterol), 15s(Uric acid)
|
|
|
Range
|
Blood glucose: 1.1-33.3mmol/L(20-600mg/dL)
|
|
|
|
Uric acid: 0.18-1.19mmol/L(3-20mg/dL)
|
|
|
|
Cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
|
|
|
Accuracy: Blood glucose
|
"When result is less than 4.2mmol/L the difference is within ±0.83mmol/L when result is more than 4.2mmol/L the difference is
±20%" |
|
|
Accuracy: Uric acid
|
(0.18mmol/L—1.19mmol/L), coefficient of variation value is within ±10%, measurement result's difference between reference result
is within ±20% |
|
|
Accuracy: Total Cholesterol
|
(2.59mmol/L—10.35mmol/L),coefficient of variation value is within±15%, measurement result's difference between reference result is
within±20% |
|
Hemoglobin tester
|
Specimen
|
Finger tip capillary whole blood
|
|
|
Volume
|
1uL
|
|
|
Test time
|
8 seconds
|
|
|
Range
|
7g/dL(4.3mmol/L)--26g/dL(16.1mmol/L)
|
|
|
|
21-78% Hct(calculation value)
|
|
|
Storage transportation temperature
|
10℃-30℃(50℉-86℉)
|
|
|
Test temperature
|
10℃-40℃(50℉-104℉)
|
|
|
Storage transportation humidity
|
10%-90%
|
|
|
Memory
|
180 groups
|
|
|
Tester dimension
|
L 77*W 61*H 19mm
|
|
|
Altitude limit
|
<10000 feet(3048m)
|
|
Urine tester
|
Communication
|
Blue tooth
|
|
|
Theory
|
Light reflection colorimetric method
|
|
|
Speed
|
60 samples/hour, highest 300 samples/hour
|
|
|
Screen
|
LCD
|
|
|
Buttons
|
5 key capacitive touching screen
|
|
|
Weight
|
160g
|
|
|
Power
|
DC 5V,1A
|
|
|
Power adaptor
|
AC100-240V,50/60HZ
|
|
|
Dimensions
|
L 110mm*W 68mm*T 27mm
|
|
|
Power consumption
|
2W
|
|
|
Life time
|
5 years
|
|
|
"Test categories 11 (categories)"
|
"LEU--Leukocyte BLD--Occult blood NIT--Nitrite KET--Ketone body UBG--Urobilinogen BIL--Bilirubin PRO--Protein GLU--Glucose pH--pH
value VC--Vitamine C SG--Specific gravity " |
|
ECG
|
Power input protection
|
Prevent tremor
|
|
|
Leads
|
12 leads or 6 leads
|
|
|
Analogue/Digit convert
|
12 bit (precision)
|
|
|
Range
|
±5mVpp
|
|
|
Time constant
|
≥3.2s
|
|
|
Frequency response
|
0.05Hz~150Hz(-3dB)
|
|
|
Calibration voltage
|
1mV±3%
|
|
|
Sensitivity
|
2.5, 5, 10, 20(mm/mV)
|
|
|
Input impedance
|
≥50MΩ
|
|
|
Input loop current
|
<0.05uA
|
|
|
Noise level
|
<15uVp-p
|
|
|
Baseline adjustment
|
Automatic
|
|
|
Patient leakage current
|
<10uA(220V-240V)
|
|
|
Patient auxiliary current
|
<0.1uA(DC)
|
|
|
Filtering
|
EMG(Electromyography) filtering
|
|
|
|
25Hz/35Hz/45Hz/off
|
|
|
|
Baseline filtering
|
|
|
|
0.05/0.15/0.25/0.5Hz
|
|
|
|
AC filter
|
|
|
|
50Hz/60Hz
|
|
|
Common mode rejection ratio
|
100dB
|
|
|
Rhythmic lead
|
Random choose
|
|
|
Safety standard
|
IEC II/CF
|
|
Ultrasonic probe for Abdomen
|
Operating system and application
|
Android smart phone (SAMSUNG S8, HUAWEI MATE 10) / Windows tablet, computer, laptop
|
|
|
Advantages
|
low power consumption, which can connected to android smart phone
|
|
|
Scanning mode
|
electric convex
|
|
|
Display mode
|
B, B/B, B/M, 4B
|
|
|
Gray scale
|
256
|
|
|
Scanning depth
|
maximum 240mm
|
|
|
TGC
|
8TGC adjustments
|
|
|
Cine loop
|
512 frames
|
|
|
Gain
|
0-100dB adjustable
|
|
|
Language
|
English/Chinese
|
|
|
Central frequency
|
3.5MHz(2.5-4.5MHz)
|
|
|
Probe port
|
USB
|
|
|
Colors
|
9
|
|
|
Image conversion
|
left/right, up/down
|
|
|
Application
|
OB/GYN, Urology, Abdomen, Emergency, and ICU
|
|
|
Net weight
|
0.2KG
|
|
Ultrasound scan for superficial tissues
|
Operating system and application
|
Android smart phone (SAMSUNG S8, HUAWEI MATE 10) / Windows tablet, computer, laptop
|
|
|
Advantages
|
low power consumption, which can connected to android smart phone
|
|
|
Scanning mode
|
electric linear
|
|
|
Display mode
|
B, B/B, B/M, 4B
|
|
|
Gray scale
|
256
|
|
|
Scanning depth
|
30-120mm
|
|
|
TGC
|
8TGC adjustments
|
|
|
Cine loop
|
512 frames
|
|
|
Gain
|
0-100dB adjustable
|
|
|
Language
|
English/Chinese
|
|
|
Central frequency
|
7.5MHz(5-10MHz)
|
|
|
Probe port
|
USB
|
|
|
Colors
|
9
|
|
|
Image conversion
|
left/right, up/down
|
|
|
Application
|
Shallow application, ultrasound-guided percutaneous drainage Small parts, such as thyroid, joint, blood vessel and so on
|
|
|
Net weight
|
0.2KG
|
|
Touch screen
|
Size
|
10.1 inches
|
|
|
Origin of coordinate
|
Right downside
|
|
|
Rohs standard
|
Compliance
|
|
|
Resolution
|
1280(RGB)*800(WXGA)
|
|
|
HW ratio
|
16:10 (width: height)
|
|
|
Pixel layout
|
RGB vertical layout
|
|
|
Dot pitch
|
0.0565*0.1695mm (horizontal*vertical)
|
|
|
Pixel spacing
|
0.1695*0.1695mm (horizontal*vertical)
|
|
|
Display area
|
216.96*135.60mm (horizontal*vertical)
|
|
|
Visible area
|
216.66*138.60mm (horizontal*vertical)
|
|
|
Dimension
|
227.42*147.69mm (horizontal*vertical)
|
|
Mother board
|
CPU
|
RK3288 4 cores Cortex-A17, 1.8G Hz
|
|
|
GPU
|
Mail-T764, Support TE,ASTC,AFBC
|
|
|
SDRAM
|
DDR3 2G(could change to 4G)
|
|
|
FLASH
|
EMMC FLASH 8GB/16G/32G, Support SATA disc, TF card Max. at 32G
|
|
|
OS
|
Android 5.1
|
|
|
Display interface
|
"1 x HDMI 2.0 , Support 4K@60 frames output 1 x MIPI, 1 x EDP, 2 x LVDS LCD interfaces"
|
|
|
Camera interface
|
"1 x DVP camera(Max. 5Mpixel) 1 x MIPI-CSI camera (Max.13Mpixel )"
|
|
|
Touch screen
|
"I2C interface(Multi point resistance touch,Multi point capacitance touch). Support USBMulti point infrared touch,Multi point nano
film touch, Multi point acoustic touch,Multi point optical touch" |
|
|
Communication
|
RJ45, 100M/1000M ethernet port
|
|
|
|
WIFI, support 2.4G/5G WIFI, support WI-FI802.11 a/b/g/n protocol
|
|
|
|
Bluetooth V2.1+EDR/Bluetooth 3.0/3.0+HS/4.0
|
|
|
|
Bluetooth V2.1+EDR/Bluetooth 3.0/3.0+HS/4.0
|
|
|
Interfaces
|
4 channel serial ports,support serial port with flow control
|
|
|
|
4 channel I2C interfaces
|
|
|
|
2 x USB2.0 HOST,1 x USB2.0 OTG
|
|
|
|
1 channel SPI interface
|
|
|
|
1 channel I2S interface
|
|
|
|
1 channel ADC interface
|
|
|
|
1 channel SDIO output
|
|
|
|
3 keypads self programmed
|
|
|
Real-time clock
|
Inbuilt real-time clock, support timing ON-OFF tablet
|
|
|
Watchdog
|
Support software, hardware watchdog
|
|
|
Audio
|
Support MP3,WMA,WAV, APE,FLAC,AAC, OGG,M4A,3GPP
|
|
|
Video
|
Support H264,VP8,MAV,WMV,AVS,263,MPEG4 with 1080P
|
|
Printer
|
|
"Printer 1: 58mm width ticket print, for text result(come with standard package) Printer 2: A4 printer, for ECG and Ultrosound
image result(Seperate package)" |
|
Power supply
|
Noise
|
Typical 35dB
|
|
|
Voltage range
|
100~240Vac
|
|
|
Frequency
|
47~63Hz, typical 50Hz
|
|
|
Output voltage
|
12.6Vdc
|
|
|
Output power
|
25.2W
|