Products
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry
High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry

High flux Extremely Nano Filtration RO Membrane NF70-8040 NF8040 for Chemical Industry

FOB Reference Price: Get Latest Price
≥1 Pieces
US $230
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Material:
Carton
Weight:
15kg
Size:
25*25*115cm
Weight (KG):
15 kg
Product name:
Reverse Osmosis RO Membrane
Max.Fe:
0.05mg/L
Max.Feed Water TOC:
3ppm
Max.Feed Water BOD:
10ppm
Max.Feed Water COD:
15ppm
Max.Feed Water Temperature:
45℃
pH Range:
3~10
Max.Turbidity NTU:
1.0
Max.Feed Water Flow:
75gpm for 8040; 16gpm for 4040,4021; 6.0gpm for 2521,2540
Max.Pressure Drop:
15psi for 8040,4040,2540; 10psi for 2521,4021

Quick Details

Core Components:
RO Membrane
Place of Origin:
Tianjin, China
Brand Name:
HatChee
Material:
Carton
Weight:
15kg
Size:
25*25*115cm
Weight (KG):
15 kg
Product name:
Reverse Osmosis RO Membrane
Max.Fe:
0.05mg/L
Max.Feed Water TOC:
3ppm
Max.Feed Water BOD:
10ppm
Max.Feed Water COD:
15ppm
Max.Feed Water Temperature:
45℃
pH Range:
3~10
Max.Turbidity NTU:
1.0
Max.Feed Water Flow:
75gpm for 8040; 16gpm for 4040,4021; 6.0gpm for 2521,2540
Max.Pressure Drop:
15psi for 8040,4040,2540; 10psi for 2521,4021
Product Description

Reverse Osmosis RO Membrane

Reverse Osmosis RO Membrane Naming Rule

Reverse Osmosis RO Membrane  Selecting Guide

Reverse Osmosis RO Membrane Dimension

2521 2540 4021 4040 Element:

Model

A/mm(inch)

B/mm(inch)

C/mm(inch)

D/mm(inch)

4021

533.4 (21)

99.7 (3.9)

19.1 (0.75)

26.7 (1.05)

4040

1016.0 (40)

99.7 (3.9)

19.1 (0.75)

26.7 (1.05)

2521

533.4 (21)

61 (2.4)

19.1 (0.75)

30.2 (1.19)

2540

1016.0 (40)

61 (2.4)

19.1 (0.75)

30.2 (1.19)

8040 Element:

Model

A/mm(inch)

B/mm(inch)

C/mm(inch)

8040

1016 (40)

201 (7.9)

29 (1.125)

Reverse Osmosis Membrane Elements Technical Data

XLP Series Membrane Elements

XLP series of membrane elements are made of Polyamide composite membrane materials, which can achieve the desired permeate water and high desalination rate under extremely low pressure operation conditions. The operating pressure is 2/3 of the ULP conventional composite membrane pressure, and the desalination rate can reach 98%. It can improve economic benefits, including reducing the investment cost of related pumps, pipelines, containers and other equipment as well as the operation cost of the whole reverse osmosis system.

XLP series of membrane elements is suitable for desalination treatment of surface water, groundwater, tap water and municipal water with salt content less than 1000 ppm. It is mainly used in various fields of industry, such as pure water, boiler recharge water, food processing and pharmaceutical manufacturing.

XLP series of membrane elements performance

Model

Active Membrane

ft2(m2)

Average Permeate

GPD(m3/d)

Stable Rejection

Min. Rejection

HC-XLP-2521

16(1.5)

450(1.7)

98.0

97.5

HC-XLP-2540

33(3.0)

900(3.4)

98.0

97.5

HC-XLP-4021

42(3.9)

1300(4.9)

98.0

97.5

HC-XLP-4040

85(7.9)

2600(9.8)

98.0

97.5

HC-XLP-8040

400(37.2)

12000(45.4)

98.0

97.5

HC-XLP-8040-440

440(40.9)

13200(49.9)

98.0

97.5

XLP series of membrane elements Testing Conditions:

Testing Pressure:100 psi (0.69MPa)

Temperature of Testing Solution:25 ℃

Concentration of Testing Solution (NaCl):500ppm

pH Value of Testing Solution:7.5

Recovery Rate of Single Element:15%

XLP series of membrane elements Operation Limits & Conditions:

Max.Working Pressure:600psi(4.14MPa)

Max.Feed Water Flow:75gpm(17 m3/h) for 8040; 16gpm(3.6 m3/h) for 4040,4021; 6.0gpm(1.4 m3/h) for 2521,2540

Max.Feed Water Temperature: 45℃

Max.Mn: 0.1mg/L

Max.Fe: 0.05mg/L

Max.Turbidity NTU: 1.0

Max.Feed Water SDI15: 5

Max.Feed Water COD: 15ppm

Max.Feed Water BOD: 10ppm

Max.Feed Water TOC: 3ppm

Residual Chlorine Concentration of Feed Water: <0.1ppm

pH Range of Feed Water During Continuous Operation: 3~10

Max.Pressure Drop of Single Element: 15psi(0.1MPa) for 8040,4040,2540; 10psi(0.07MPa) for 2521,4021

ULP Series Membrane Elements

ULP series of membrane elements are made of Polyamide composite membrane materials, which can achieve the desired permeate water and high desalination rate under ultra-low/extreme-low pressure operation conditions. The operating pressure is 2/3 of the BW conventional composite membrane pressure, and the desalination rate can reach 99.3%. It can improve economic benefits, including reducing the investment cost of related pumps, pipelines, containers and other equipment as well as the operation cost of the whole reverse osmosis system.

ULP series of membrane elements is suitable for desalination treatment of surface water, groundwater, tap water and municipal water with salt content less than 2000 ppm. It is mainly used in various fields of industry, such as pure water, boiler recharge water, food processing and pharmaceutical manufacturing.

ULP series of membrane elements performance

Model

Active Membrane

ft2(m2)

Average Permeate

GPD(m3/d)

Stable Rejection

Min. Rejection

HC-ULP-2521

16(1.5)

400(1.5)

99.5

99.3

HC-ULP-2540

33(3.0)

800(3.0)

99.5

99.3

HC-ULP-4021

42(3.9)

1100(4.2)

99.5

99.3

HC-ULP1-4040

85(7.9)

3100(11.7)

99.0

98.5

HC-ULP2-4040

85(7.9)

2700(10.2)

99.3

99.0

HC-ULP3-4040

85(7.9)

2200(8.3)

99.5

99.3

HC-ULP1-8040

400(37.2)

14000(53)

99.0

98.5

HC-ULP2-8040

400(37.2)

12000(45.4)

99.3

99.0

HC-ULP3-8040

400(37.2)

10500(39.7)

99.5

99.3

HC-ULP3-8040-440

440(40.9)

12000(45.4)

99.5

99.3

ULP series of membrane elements Testing Conditions:

Testing Pressure:150 psi (1.03MPa)

Temperature of Testing Solution:25 ℃

Concentration of Testing Solution (NaCl):1500ppm

pH Value of Testing Solution:7.5

Recovery Rate of Single Element:15%

ULP series of membrane elements Operation Limits & Conditions:

Max.Working Pressure:600psi(4.14MPa)

Max.Feed Water Flow:75gpm(17 m3/h) for 8040; 16gpm(3.6 m3/h) for 4040,4021; 6.0gpm(1.4 m3/h) for 2521,2540

Max.Feed Water Temperature: 45℃

Max.Mn: 0.1mg/L

Max.Fe: 0.05mg/L

Max.Turbidity NTU: 1.0

Max.Feed Water SDI15: 5

Max.Feed Water COD: 15ppm

Max.Feed Water BOD: 10ppm

Max.Feed Water TOC: 3ppm

Residual Chlorine Concentration of Feed Water: <0.1ppm

pH Range of Feed Water During Continuous Operation: 3~10

Max.Pressure Drop of Single Element: 15psi(0.1MPa) for 8040,4040,2540; 10psi(0.07MPa) for 2521,4021

BW Series FR Series Membrane Elements

BW series is an aromatic polyamide composite membrane element for desalination of brackish water. It has the characteristics of high water production and good desalination performance. In addition, it has high performance of removing soluble salts, TOC and SiO2, and is especially suitable for the making of high purified water in the electronics and power industries.

It is suitable for desalination treatment of surface water, groundwater, tap water and municipal water with salt content less than 5,000 ppm. It is mainly used for industrial pure water of various scales, boiler feed water of power plants and other industrial water. It can also be used for the treatment of brackish water applications such as high concentration saline waste water and beverage water manufacturing.

FR series, the surface of this membrane was treated by special technology, which changed the electric charge and smoothness of the membrane surface, increased the hydrophilicity of the membrane surface, thus reducing the contamination of pollutants and microorganisms on the membrane surface, and achieving the purpose of reducing the contamination of membrane components and prolonging the service life.

BW series FR series of membrane elements performance:

Model

Active Membrane

ft2(m2)

Average Permeate

GPD(m3/d)

Stable Rejection

Min. Rejection

HC-BW-2521

16(1.5)

400(1.5)

99.7

99.5

HC-BW-2540

33(3.0)

800(3.0)

99.7

99.5

HC-BW-4021

42(3.9)

1100(4.2)

99.7

99.5

HC-BW-4040

85(7.9)

2400(9.1)

99.7

99.5

HC-BW-8040

400(37.2)

10500(39.7)

99.7

99.5

HC-BW-8040-440

440(40.9)

12000(45.4)

99.7

99.5

HC-FR-4040

400(37.2)

2400(9.1)

99.7

99.5

HC-FR-8040

440(40.9)

10500(39.7)

99.7

99.5

BW series FR series of membrane elements Testing Conditions:

Testing Pressure:225 psi (1.5MPa)

Temperature of Testing Solution:25 ℃

Concentration of Testing Solution (NaCl):2000ppm

pH Value of Testing Solution:7.5

Recovery Rate of Single Element:15%

BW series FR series of membrane elements Operation Limits & Conditions:

Max.Working Pressure:600psi(4.14MPa)

Max.Feed Water Flow:75gpm(17 m3/h) for 8040; 16gpm(3.6 m3/h) for 4040,4021; 6.0gpm(1.4 m3/h) for 2521,2540

Max.Feed Water Temperature: 45℃

Max.Mn: 0.1mg/L

Max.Fe: 0.05mg/L

Max.Turbidity NTU: 1.0

Max.Feed Water SDI15: 5

Max.Feed Water COD: 15ppm

Max.Feed Water BOD: 10ppm

Max.Feed Water TOC: 3ppm

Residual Chlorine Concentration of Feed Water: <0.1ppm

pH Range of Feed Water During Continuous Operation: 3~10

Max.Pressure Drop of Single Element: 15psi(0.1MPa) for 8040,4040,2540; 10psi(0.07MPa) for 2521,4021

SW Series Membrane Elements

SW Series is an aromatic polyamide composite membrane element for seawater desalination. By optimizing the structure of membrane element, this series of membrane elements can increase water production. Under the same water production requirement, the number of membrane elements can be reduced. It has the characteristics of low operating pressure, low equipment investment, good desalination performance and stability. In particular, its high desalination rate ensures that drinking water can be obtained from seawater through first-order reverse osmosis.

SW series membrane elements are suitable for the treatment of seawater and brackish water with high concentration. They can be used for the treatment of seawater desalination, desalination of brackish water with high concentration, boiler feed water in power plants, wastewater reuse, concentration and recovery of high value-added substances such as food and medicine, etc.

SW series of membrane elements performance:

Model

Active Membrane

ft2(m2)

Average Permeate

GPD(m3/d)

Stable Rejection

Min. Rejection

HC-SW-2521

16(1.5)

270(1.0)

99.5

99.3

HC-SW-2540

33(3.0)

600(2.3)

99.5

99.3

HC-SW-4021

42(3.9)

750(2.8)

99.5

99.3

HC-SW-4040

85(7.9)

1600(6.1)

99.5

99.3

HC-SW-8040

400(37.2)

7500(28.4)

99.8

99.5

HC-SW-8040-440

440(40.9)

8250(31.2)

99.8

99.5

SW series of membrane elements Testing Conditions:

Testing Pressure:800 psi (5.5MPa)

Temperature of Testing Solution:25 ℃

Concentration of Testing Solution (NaCl):32000ppm

pH Value of Testing Solution:7.5

Recovery Rate of Single Element:8%

SW series of membrane elements Operation Limits & Conditions:

Max.Working Pressure:1200psi(8.3MPa)

Max.Feed Water Flow:75gpm(17 m3/h) for 8040; 16gpm(3.6 m3/h) for 4040,4021; 6.0gpm(1.4 m3/h) for 2521,2540

Max.Feed Water Temperature: 45℃

Max.Mn: 0.1mg/L

Max.Fe: 0.05mg/L

Max.Turbidity NTU: 1.0

Max.Feed Water SDI15: 5

Max.Feed Water COD: 15ppm

Max.Feed Water BOD: 10ppm

Max.Feed Water TOC: 3ppm

Residual Chlorine Concentration of Feed Water: <0.1ppm

pH Range of Feed Water During Continuous Operation: 3~10

Max.Pressure Drop of Single Element: 15psi(0.1MPa) for 8040,4040,2540; 10psi(0.07MPa) for 2521,4021

NF Series Membrane Elements

NF Series of nanofiltration membrane elements can achieve high permeate water and excellent desalination performance. Therefore, it is suitable for large-scale industrial and municipal water treatment systems. In use, it shows excellent ability to remove pesticides, viruses and bacteria. It has high ability to remove natural organic substances and medium ability to remove total hardness. Through innovative technology, the product has a stronger film surface, strong anti-oxidation performance, and the use of ultra- low pressure mode of operation can significantly improve the system and operation economy.

NF series of membrane elements performance:

Model

Active Membrane

ft2(m2)

Average Permeate

GPD(m3/d)

Stable Rejection

%

HC-NF60-4040

85(7.9)

2000(7.5)

60±10

500 NaCl

≥97

2000 MgO4

HC-NF60-8040

400(37.2)

10000(37.9)

60±10

500 NaCl

≥97

2000 MgO4

HC-NF90-4040

85(7.9)

1800(6.8)

90±10

500 NaCl

≥98

2000 MgO4

HC-NF90-8040

400(37.2)

9000(34.1)

90±10

500 NaCl

≥98

2000 MgO4

NF series of membrane elements Testing Conditions:

Testing Pressure:70 psi (0.48MPa)

Temperature of Testing Solution:25 ℃

Concentration of Testing Solution:500ppm NaCl;2000ppm MgSO4

pH Value of Testing Solution:8

Recovery Rate of Single Element:15%

NF series of membrane elements Operation Limits & Conditions:

Max.Working Pressure:600psi(4.14MPa)

Max.Feed Water Flow:75gpm(17 m3/h) for 8040; 16gpm(3.6 m3/h) for 4040,4021; 6.0gpm(1.4 m3/h) for 2521,2540

Max.Feed Water Temperature: 45℃

Max.Mn: 0.1mg/L

Max.Fe: 0.05mg/L

Max.Turbidity NTU: 1.0

Max.Feed Water SDI15: 5

Max.Feed Water COD: 15ppm

Max.Feed Water BOD: 10ppm

Max.Feed Water TOC: 3ppm

Residual Chlorine Concentration of Feed Water: <0.1ppm

pH Range of Feed Water During Continuous Operation: 3~10

Max.Pressure Drop of Single Element: 15psi(0.1MPa) for 8040,4040,2540; 10psi(0.07MPa) for 2521,4021

Note:

1.For the recommended design scope, please refer to the latest version of the technical manual, design guide, or consult with membrane technology experts. If the user does not strictly follow the operating conditions provided by the sample, Tianjin Justin  Technology Co., Ltd will not bear all the consequences arising therefrom.

2.The average water yield listed in the table shows that the error of water yield of single membrane element in series is within (+10%). The difference between the minimum water yield and the nominal value of other series of single membrane elements is not more than 20% of the nominal value.

3.Wet membrane components are strictly tested before they leave the factory. They are stored in 1.0% sodium bisulfite solution. Then they are packed in vacuum and packed in cardboard boxes. The safe storage temperature of wet membrane components is 4-45℃.

4.RO production water to be discharged in the first hour of operation.

5.During storage and operation, it is prohibited to add any chemicals that affect membrane components. In case of violating the use of such chemicals, Tianjin Justin  Technology Co., Ltd will not bear all the consequences arising therefrom.

Product Show