- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
SMP21
-
Measuring Range:
-
-100kPa...0kPa~20kPa...70MPa
-
Power supply:
-
Max 2.0 mA DC
-
Impedance input:
-
2.5kΩ ~ 5 kΩ
Quick Details
-
Warranty:
-
3 years
-
Place of Origin:
-
Shaanxi, China
-
Brand Name:
-
Sensors
-
Model Number:
-
SMP21
-
Measuring Range:
-
-100kPa...0kPa~20kPa...70MPa
-
Power supply:
-
Max 2.0 mA DC
-
Impedance input:
-
2.5kΩ ~ 5 kΩ
Products Information
Overview
SMP2100 ST constant voltage normalized output pressure sensor can be connected to the power supply directly,reduce customers using constant current source electronic circuits. Output can be 100mv±1% FS output.
Feature
* Range : -100kPa…0kPa~20kPa…70MPa
* Power supply: 10V
* Output: 100mV ±2mv
φ19mm*11.5mm standard OEM pressure sensor
* Power supply: 10V
* Output: 100mV ±2mv
φ19mm*11.5mm standard OEM pressure sensor
Construction Condition
|
|
|
Diaphragm material
|
SS 316L
|
|
Housing material
|
SS 316L
|
|
Pin Wire
|
Gold-plated karaf /100mm silicone rubber wire
|
|
Back pressure tube
|
SS 316L (gauge and negative pressure only)
|
|
Seal ring
|
Nitrile rubber
|
|
Electrical Condition
|
|
|
Power supply
|
≤10V DC
|
|
Impedance input
|
4kΩ~25kΩ
|
|
Impedance output
|
3.5kΩ~6kΩ
|
|
Response
|
(10%~90%):<1ms
|
|
Insulation resistance
|
100MΩ,100V DC
|
|
Overpressure
|
2 times FS
|
|
Environmental Condition
|
|
|
Media applicability
|
Fluid which has no corrosion on stainless steel and nitrile rubber
|
|
Shock
|
No change at 10gRMS,(20~2000)Hz
|
|
Impact
|
100g,11ms
|
|
Position
|
Deviate 90° from any direction, zero change≤±0.05%FS
|
|
Basic Condition
|
|
|
Environment temperature
|
(25±1)℃
|
|
Humidity
|
(50%±10%)RH
|
|
Atmospheric pressure
|
(86~106) kPa
|
|
Power supply
|
(1.5±0.0015)mA DC
|
Item
|
Min.
|
Typ.
|
Max.
|
Units
|
||
Linearity
|
|
±0.1
|
±0.2
|
%FS,BFSL
|
||
Repeatability
|
|
±0.05
|
±0.075
|
%FS
|
||
Hysteresis
|
|
±0.05
|
±0.075
|
%FS
|
||
Zero output
|
|
|
±2.0
|
mV DC
|
||
FS output
|
98
|
100
|
102
|
mV DC
|
||
Compensated temp. range
|
0~70
|
|
|
℃
|
||
Working temp. range
|
-40~125
|
|
|
℃
|
||
Storage temp. range
|
-55~150
|
|
|
℃
|
||
Zero temp. error
|
|
±0.75
|
±1.0
|
%FS, @25℃
|
||
Full temp. error
|
|
±0.75
|
±1.0
|
%FS, @25℃
|
||
Long term stability error
|
|
±0.1
|
|
%FS/year
|
Details Images
Outline Construction:(Unit: mm) Electrical connection
Application
Why Choose Us
Hot Searches