- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
BS029B
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
BESTER
-
Theory:
-
PIR / Microwave sensor
-
Brand:
-
microwave doppler radar sensor
-
Voltage - Supply:
-
220V-240V
-
Output Type:
-
220V-240V
-
Operating Temperature:
-
-15~+75
-
Frequency:
-
50/60
-
Humidity Range:
-
<93%
-
Sensing Distance:
-
1-8M
-
Voltage - Max:
-
240V
-
Current Rating - AC:
-
220V-240V
-
Voltage - Input:
-
220V-240V
-
Power supply:
-
220-240VAC
-
Power frequency:
-
50/60Hz
-
Installation sit:
-
Indoors, ceiling mounting
-
Transmission power:
-
<0.2mW
-
Detection angle:
-
360°
-
Detection distance:
-
1-8m, adjustable
-
Time setting:
-
8sec to 12min
-
Light control:
-
2~2000LUX
-
Power consumption:
-
0.9W
-
Size:
-
90x41x38
Quick Details
-
Use:
-
Microwave sensor light
-
Mounting Type:
-
ceiling type, Ceiling Mounted
-
Description:
-
microwave motion sensor
-
Model Number:
-
BS029B
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
BESTER
-
Theory:
-
PIR / Microwave sensor
-
Brand:
-
microwave doppler radar sensor
-
Voltage - Supply:
-
220V-240V
-
Output Type:
-
220V-240V
-
Operating Temperature:
-
-15~+75
-
Frequency:
-
50/60
-
Humidity Range:
-
<93%
-
Sensing Distance:
-
1-8M
-
Voltage - Max:
-
240V
-
Current Rating - AC:
-
220V-240V
-
Voltage - Input:
-
220V-240V
-
Power supply:
-
220-240VAC
-
Power frequency:
-
50/60Hz
-
Installation sit:
-
Indoors, ceiling mounting
-
Transmission power:
-
<0.2mW
-
Detection angle:
-
360°
-
Detection distance:
-
1-8m, adjustable
-
Time setting:
-
8sec to 12min
-
Light control:
-
2~2000LUX
-
Power consumption:
-
0.9W
-
Size:
-
90x41x38
Products Description
Product Paramenters
Instruction
* The sensor is an active motion detector
* It emits high-frequency electro-magnetic wave(5.8GHz) and receives their echo.
* The sensor detects the change in echo from even the slightest movement in its detection zone.
* A microprocessor then triggers the “switch light ON” command.
* Detection is possible through doors, panes of glass or thin walls.
Important: persons or objects moving towards the sensor are detected best!
* The sensor is an active motion detector
* It emits high-frequency electro-magnetic wave(5.8GHz) and receives their echo.
* The sensor detects the change in echo from even the slightest movement in its detection zone.
* A microprocessor then triggers the “switch light ON” command.
* Detection is possible through doors, panes of glass or thin walls.
Important: persons or objects moving towards the sensor are detected best!
Details Images for
microwave doppler radar sensor



Installation Instructions
* The sensor is an active motion detector
* It emits high-frequency electro-magnetic wave(5.8GHz) and receives their echo.
* The sensor detects the change in echo from even the slightest movement in its detection zone.
* A microprocessor then triggers the “switch light ON” command.
* Detection is possible through doors, panes of glass or thin walls.
Important: persons or objects moving towards the sensor are detected best!
* It emits high-frequency electro-magnetic wave(5.8GHz) and receives their echo.
* The sensor detects the change in echo from even the slightest movement in its detection zone.
* A microprocessor then triggers the “switch light ON” command.
* Detection is possible through doors, panes of glass or thin walls.
Important: persons or objects moving towards the sensor are detected best!
Specifications for microwave doppler radar sensor
Model No.
|
microwave doppler radar sensor BS029B
|
Power Sourcing
|
220V/AC-240V/AC
|
Detection Range
|
360°
|
Detection Distance
|
1-8m (radius) adjustable
|
HF System
|
5.8GHz CW radar, ISM band
|
Ambient Light
|
2-2000LUX (Adjustable)
|
Time setting
|
8sec-12min
|
Transmission Power
|
<0.2mW
|
Power Consumption
|
0.9W
|
Installation sit
|
Indoors ,ceiling mounting
|
Rated Load
|
1200W (220-240VAC)
|
Practicality Fuctions
1) Reach setting (sensitivity)
Reach is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 2.5m, turn the reach control fully anticlockwise to select minimum reach (approx.1 m radii), and fully clockwise to select maximum reach (approx. 8m radii).
NOTE: the above detection distance is gained in the case of a person who is between 1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s stature, figure and moving speed change, the detection distance will also change.
2) Time setting
The light can be set to stay ON for any period of time between approx. 8sec (turn fully anti-clockwise) and a maximum of 12min (turn fully clockwise). Any movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time for adjusting the detection zone and for performing the walk test.
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start detecting movement again. The light will only switch on in response to movement once this period has elapsed.
3) Light-control setting
The chosen light response threshold can be infinitely from approx. 2-2000lux. Turn it fully anti-clockwise to select dusk- to-dawn operation at about 2 lux. Turn it fully clockwise to select daylight operation at about 2000lux. The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight.
The high-frequency output of this sensor is <10Mw- that is just one 100th of the transmission power of a mobile phone or the output of a microwave oven
1) Reach setting (sensitivity)
Reach is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 2.5m, turn the reach control fully anticlockwise to select minimum reach (approx.1 m radii), and fully clockwise to select maximum reach (approx. 8m radii).
NOTE: the above detection distance is gained in the case of a person who is between 1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s stature, figure and moving speed change, the detection distance will also change.
2) Time setting
The light can be set to stay ON for any period of time between approx. 8sec (turn fully anti-clockwise) and a maximum of 12min (turn fully clockwise). Any movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time for adjusting the detection zone and for performing the walk test.
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start detecting movement again. The light will only switch on in response to movement once this period has elapsed.
3) Light-control setting
The chosen light response threshold can be infinitely from approx. 2-2000lux. Turn it fully anti-clockwise to select dusk- to-dawn operation at about 2 lux. Turn it fully clockwise to select daylight operation at about 2000lux. The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight.
The high-frequency output of this sensor is <10Mw- that is just one 100th of the transmission power of a mobile phone or the output of a microwave oven
Installation (see the diagram)
* Connect N, L with power
* Connect N, L’ with load
* Connect N, L with power
* Connect N, L’ with load

Note
* Electrician or experienced human can install it.
* The unrest objects can’t be regarded the installation basis-face.
* In front of the detection window there shouldn’t be hinder or unrest objects effecting detection.
* Avoid installing it near air temperature alteration zones for example: air condition, central heating, etc.
* For your safety. Please don’t open the case if you find hitch after installation.
* In order to avoid the unexpected damage of product, please add a safe device of 6A when installing infrared sensor, for
example, fuse, safe tube etc.
Some problem and solved way
The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light does not turn on after sensing, please check if the working light corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check if in front of the detection window there are hinder that effect to receive the signals.
b. Please check the ambient temperature.
c. Please check if the signals source is in the detection fields.
d. Please check the installation height.
The sensor can’t shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power correspond to the instruction.
d. If the air temperature change near the sensor, air condition or central heating
* Electrician or experienced human can install it.
* The unrest objects can’t be regarded the installation basis-face.
* In front of the detection window there shouldn’t be hinder or unrest objects effecting detection.
* Avoid installing it near air temperature alteration zones for example: air condition, central heating, etc.
* For your safety. Please don’t open the case if you find hitch after installation.
* In order to avoid the unexpected damage of product, please add a safe device of 6A when installing infrared sensor, for
example, fuse, safe tube etc.
Some problem and solved way
The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light does not turn on after sensing, please check if the working light corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check if in front of the detection window there are hinder that effect to receive the signals.
b. Please check the ambient temperature.
c. Please check if the signals source is in the detection fields.
d. Please check the installation height.
The sensor can’t shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power correspond to the instruction.
d. If the air temperature change near the sensor, air condition or central heating
Hot Searches