- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
AIT
-
Model Number:
-
AMF200
-
Product Name:
-
4-20mA Electromagnetic induction flowmeter
-
Accuracy:
-
0.2%
-
Application:
-
Widely
-
Power supply:
-
AC85~265V,24Vdc, 12Vdc
-
Protection Class:
-
IP67/IP68
-
Flow range:
-
10m/s
-
Ambient temperature:
-
-40...+85C
-
Electrode material:
-
SUS316L/HC/Titanium/Tantalu
Quick Details
-
Type:
-
Variable Area Water Flowmeters, Variable Area Air & Gas Flowmeters, Variable Area Petrolum Flowmeters, Variable Area Oil Flowmeters
-
Warranty:
-
1 year, 12 Months
-
Place of Origin:
-
Shanghai, China
-
Brand Name:
-
AIT
-
Model Number:
-
AMF200
-
Product Name:
-
4-20mA Electromagnetic induction flowmeter
-
Accuracy:
-
0.2%
-
Application:
-
Widely
-
Power supply:
-
AC85~265V,24Vdc, 12Vdc
-
Protection Class:
-
IP67/IP68
-
Flow range:
-
10m/s
-
Ambient temperature:
-
-40...+85C
-
Electrode material:
-
SUS316L/HC/Titanium/Tantalu
0.2% accuracy 4-20mA Electromagnetic induction flowmeter
Product Description
Product Paramenters
Range dimension / lining material
|
PTFE DN10 - DN500
|
|
RUBBER DN65 - DN2000
|
Sensor material
|
SS321
|
Housing material
|
aluminium
|
Electrodes material
|
SS316L - Hastelloy C - Titanium - Tantalum - Platinum
|
Measure range
|
<0,1m3/h - >110000m3/h
|
Accuracy
|
±0,5% standard; ±0,2% optional
|
Repeatability
|
±0,1%
|
Fluid conductivity
|
>5pS/cm.
|
Power supply
|
85-265Vac, 24Vdc, 12Vdc.
|
Consumption
|
6W, max. 8W.
|
Ambient Temperature Limits
|
|
Remote version operating temperature:
|
RUBBER -10 - +80°C; PTFE -40 - +150°C
|
Compact version operating temperature:
|
RUBBER -10 - +80°C; PTFE -40 - +100°C
|
Storage temperature:
|
-40+85°C
|
Communication protocol
|
modbus or Hart (opt.)
|
Output
|
|
4+20mA:
|
0+750 ohm load.
|
Frequency output:
|
0,1+5000 Hz
|
Pulse output:
|
24Vdc pull up open collector or galvanically isolated open collector (opt.)
|
Alarm output:
|
2 relays, 3A 230Vac N.O. (not available for 12Vdc power supply version)
|
Reverse Flow
|
Allow measure reverse flow.
|
Output Testing
|
|
Current Source:
|
Transmitter can be commanded to supply a specified test current between 4.0 and 20.0 mA.
|
Frequency Source:
|
Transmitter can be commanded to supply a specified test frequency between 0.1 and 5000 Hz
|
Start-up Time
|
0.5 seconds.
|
Low Flow Cutoff
|
Adjustable between 0.0 and 9.9%Qmax. Below selected value, output is driven to the zero flow rate signal level.
|
Humidity Limits
|
0-100% RH to 150 °F (65 °C), not condensing.
|
Damping
|
Adjustable between 0.1 and 99 seconds.
|
Compact version IP rating
|
IP67
|
Remote version IP rating
|
sensor IP67 / IP68 (by request) - converter IP67
|
Anti-condensation filter
|
Anti-condensation filter installed on converter
|