Products
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear
XGN2 12KV 630-2500A high voltage switchgear equipment   Medium voltage switchgear

XGN2 12KV 630-2500A high voltage switchgear equipment Medium voltage switchgear

FOB Reference Price: Get Latest Price
≥1 Pieces
US $916.37
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Place of Origin:
Zhejiang, China
Brand Name:
SINAIDE
Model Number:
XGN2-12
Material:
metal
Rated Voltage:
3-12KV
Product name:
fixed metal-clad movable switchgear
Rated short circuit breaking current:
20/25/31.5KA
Rated short time withstand current:
50/63/80KA
Rated peak withstand current:
50/63/80KA
Rated power frequency withstand voltage:
42KV
Rated lighting impulse withstand voltage:
75KV
Degree of Protection:
IP3X
Package:
wooden case
Phase:
3 Phase 4 Wire

Quick Details

Voltage:
12
Current:
630
Size:
900
Place of Origin:
Zhejiang, China
Brand Name:
SINAIDE
Model Number:
XGN2-12
Material:
metal
Rated Voltage:
3-12KV
Product name:
fixed metal-clad movable switchgear
Rated short circuit breaking current:
20/25/31.5KA
Rated short time withstand current:
50/63/80KA
Rated peak withstand current:
50/63/80KA
Rated power frequency withstand voltage:
42KV
Rated lighting impulse withstand voltage:
75KV
Degree of Protection:
IP3X
Package:
wooden case
Phase:
3 Phase 4 Wire

Product Description:

XGN2-12 box-type fixed metal-enclosed switchgear (referred to as switchgear) is used for receiving and distributing electric energy in 3.6, 7.2, 12kv three-phase AC 50Hz systems, suitable for frequent operation occasions, and its busbar system is a single busbar (and can be derived single bus with bypass and double bus structure). The switchgear meets the requirements of the national standard GB3906-91 (3-35kv AC metal-enclosed switchgear) and the national standard IEC298, and has two proposed "five-proof" locking functions.
The main switch of the switch cabinet adopts ZN28-12 series vacuum circuit breaker, equipped with CDI7 series electromagnetic operating mechanism or CT19 series spring operating mechanism, and the isolating switch adopts GN30-12 rotary isolating switch or GN22-12 high current isolating switch series.

Product features:

1: The switch cabinet is a metal closed box structure, and the cabinet frame is welded with angle steel. The cabinet is divided into circuit breaker room, bus room, cable room and relay room. The interior is separated by steel plates.
2: The circuit breaker room is located at the lower part of the cabinet, and the circuit breaker drive is connected by the pull rod and the operating mechanism; the lower end of the circuit breaker is connected to the current transformer, the current transformer is connected to the isolating switch terminal, and the upper end of the circuit breaker is connected to the isolating switch terminal. The circuit breaker room is also provided with a pressure relief channel. If arcing occurs inside, the gas can be released through the exhaust channel.
3: The busbar compartment is at the rear upper part of the cabinet. In order to reduce the height of the cabinet, The busbar arrangement shape is , it is supported by a porcelain insulator with a bending strength of 7350N, and the busbar is connected to the upper isolating switch terminal.
4: The cable compartment is behind the lower part of the cabinet. The support insulators in the cable compartment can be equipped with monitoring devices and the cables are fixed on the brackets. The contact is the wiring communication cable M of this room
5: The operating mechanism of the circuit breaker is installed at the lower left, above which is the operating interlocking mechanism of the isolating switch.
6: The switch cabinet is double-sided maintenance. In the front, the secondary components of the relay room are inspected, the operating mechanism, mechanical interlock and transmission parts are maintained, the circuit breaker is inspected, and the upper busbar and cable terminals are repaired in the rear. Lights are installed in the circuit breaker room and the cable room.
7:There is a grounding copper bar parallel to the width of the cabinet below the front, and its cross-section is 4*40mm². Mechanical interlock: prevent the on-load isolating switch; prevent the circuit breaker from accidentally opening and closing; prevent the grounding knife from closing.

Product  parameters:

Product details:

Production workshop:

Product packaging and transportation:

Product application case:

FAQ:
What is a switchgear?
A switchgear is a device used for controlling, protecting, and distributing electricity, commonly found in power systems and industrial electrical equipment.
What is the function of a switchgear?
The switchgear is used to control the flow of current, protect electrical equipment and power systems from the effects of current overload, short circuits, and other faults, and distribute current to various electrical equipment.
What are the different types of switchgear?
Common types of switchgear include low-voltage switchgear, medium voltage switchgear, and high-voltage switchgear, which are distinguished based on different voltage levels and usage scenarios.
What are the main components of a switchgear?
A switchgear typically includes components such as circuit breakers, load switches, protective devices, control components, and power connections.
What are the key points for selecting switchgear?
When selecting a switchgear, factors such as current load, voltage level, environmental conditions, protection functions, and control requirements need to be considered.
Does the switchgear require regular maintenance?
Yes, the switchgear needs regular inspection and maintenance to ensure its normal operation and safety performance.
Does the switchgear have a protective function?
Yes, switchgear usually includes functions such as short circuit protection, overload protection, undervoltage protection, etc. to protect the safe operation of electrical equipment and power systems.

APP
Post My RFQ
WhatsApp
+86-17326049340