In addition, it can also be used in various commercial places or home places.
- Product Details
- {{item.text}}
Quick Details
-
After-sales Service Provided:
-
Video technical support
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Hengshuangda
-
Model Number:
-
HSD-1660, HSD-1530, HSD-1460A, HSD-1460B, HSD-1260, HSD-1060, HSD-850, HSD-760, HSD-660, HSD-560
-
Voltage:
-
110V - 415V
-
Name:
-
Roof-Mounted AC Exhaust Fan
-
Power supply:
-
110V-415V
-
Function:
-
Exhaust Air
-
Frame Material:
-
SMC FRP- Fiberglass Reinforced Plastic Steel
-
Blades Material:
-
SMC FRP- Fiberglass Reinforced Plastic Steel
-
Blade Rotates:
-
Direct drive
-
Keyword:
-
Exhaust Fan Ventilation
-
Used for:
-
Greenhouse,poultry house,warehouse,workshop etc
Quick Details
-
Applicable Industries:
-
Hotels, Garment Shops, Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Food & Beverage Factory, Farms, Restaurant, Food Shop, Printing Shops, Construction works , Energy & Mining, Food & Beverage Shops, Advertising Company, Other
-
Electric Current Type:
-
AC
-
Mounting:
-
Wall / Window Mounted
-
After-sales Service Provided:
-
Video technical support
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Hengshuangda
-
Model Number:
-
HSD-1660, HSD-1530, HSD-1460A, HSD-1460B, HSD-1260, HSD-1060, HSD-850, HSD-760, HSD-660, HSD-560
-
Voltage:
-
110V - 415V
-
Name:
-
Roof-Mounted AC Exhaust Fan
-
Power supply:
-
110V-415V
-
Function:
-
Exhaust Air
-
Frame Material:
-
SMC FRP- Fiberglass Reinforced Plastic Steel
-
Blades Material:
-
SMC FRP- Fiberglass Reinforced Plastic Steel
-
Blade Rotates:
-
Direct drive
-
Keyword:
-
Exhaust Fan Ventilation
-
Used for:
-
Greenhouse,poultry house,warehouse,workshop etc
Mounted Fiberglass (FRP) Exhaust Fan
for indoor space ventilation
How to effectively ventilate medium and large factories has always been a difficult problem. The fiberglass exhaust fan can effectively solve the problem. The exhaust fan blows air through the fan blades, making the indoor environment form a negative pressure environment, and can also introduce fresh air while exhausting exhaust air.
The fiberglass exhaust fan is a low-energy exhaust fan that focuses on solving ventilation problems. Made of reinforced fiberglass material. ( FRP )
1. Axial Fan
2. 9000-90000 m³/h Big Airflow
Axial fan type industrial Exhaust Fan.
10 different standard models with varying power/specifications are available for selection,
and we also offer customized products, including each parameter.
3. Can Cover Large Area
Single unit HSD-1660
Exhaust Fan with 90000 m³/h airflow, suitable for 900 sqm.
3. Can Cover Large Area
4.
Easy to Install
After customizing the size of the exhaust fan, you can reserve an installation space on the window or wall for installation.
5. Two Type of Air Ducts can be choose
There are two types of air ducts to choose from, which can control the wind direction
while adding water resistance.
Product Parameters
HSD-1660
1.5KW
Front View
HSD-1660 1.5KW
Rear View
HSD-1660 1.5KW
Side View
Model
|
Power
(KW)
|
Blade
Diameter(mm)
|
Voltage
(V)
|
Max Air Volume
(m³/h)
|
Weight
(kg)
|
Dimensions
(mm)
|
HSD-1660
|
1.5
|
1490
|
110-415
Customizable
|
90000
|
98
|
1700* 1700* 640
|
HSD-1530
|
1.1
|
1370
|
110-415
Customizable |
68000
|
85
|
1580* 1580* 630
|
HSD-1460A
|
1.1
|
1250
|
110-415
Customizable |
48000
|
75
|
1460* 1460* 580
|
HSD-1460B
|
0.75
|
1250
|
110-415
Customizable
|
45000
|
65
|
1460* 1460* 580
|
HSD-1260
|
0.75
|
1050
|
110-415
Customizable
|
37000
|
50
|
1260* 1260* 560
|
HSD-1060
|
0.55
|
850
|
110-415
Customizable
|
32000
|
50
|
1060* 1060* 500
|
HSD-850
|
0.37
|
660
|
110-415
Customizable
|
28000
|
35
|
850* 850* 480
|
HSD-760
|
0.55
|
570
|
110-415
Customizable
|
18000
|
32
|
760* 760* 440
|
HSD-660
|
0.55
|
490
|
110-415
Customizable
|
13000
|
30
|
660* 660* 440
|
HSD-560
|
0.37
|
380
|
110-415
Customizable
|
9000
|
28
|
560* 560* 430
|
Product Feature
Shell of SMC Fiberglass
The shell is made of reinforced fiberglass, which is light, strong and anti-corrosion.
Double-Side Shutter
There are Shutters on the inside and outside to further enhance the rain protection.
Two types of elbow ducts can be installed
After installing the elbow air duct, you can control the wind direction and increase the air volume by 10-15%
Fan Motor
Fully copper motor, quiet and durable
Leakage protection, high current grounding wire
FRP Fan Blades
Fan Blades are made of Reinforce Fiberglass (FRP) Material
have long service life and low noise
Double Shutter
Effectively Prevent Rainwater Intrusion
can be opened or closed without the need for electricity
45° and 90° Elbow
Elbow air duct is optional to prevent air backflow while improving water resistance, and the air volume is increased by 10-15%.
Installation Instructions
Exhaust Fan - Cooling Pad Cooling System
The cooling principle of exhaust fan is to create negative pressure indoor when the fan is turned on. Forcing the hot air out of the indoor and letting in fresh air in.
If the outdoor temperature is 32 degrees
Celsius (
89.6 degrees
Fahrenheit
)
then the indoor temperature can reach up to 38℃. After turning on our exhaust fan, the indoor temperature can reduce to 28℃. The cooling effect is significant.
Notice: Exhaust fans should be installed on the same wall of the building to create one direction air flow. ( If the exhaust fans are installed on the opposite walls , it will not create an one direction air flow, the ventilation effect will reduce)
Installation Instructions With Bracket
Expansion Screw:
Mount on the wall.
Self-Tapping Screws: Fix exhaust fan to iron bracket.
Self-Tapping Screws: Fix exhaust fan to iron bracket.
Iron Bracket:
Fix exhaust fan to the wall.
Tripod:
Fix exhaust fan to iron bracket and fix iron bracket to the wall.
Installation Instructions In Wall
❶Reserved hole size for fan:
Height:
fan size+10mm ( fan’s lower edge is close to wall and leaving 1cm space on the upper edge)
Width: fan size+20mm ( Both left and right edges leaving 1cm space) Fan size can be found in our
Width: fan size+20mm ( Both left and right edges leaving 1cm space) Fan size can be found in our
product parameters
❷Insert Styrofoam into the vacant gaps between the fan and the wall Then smooth the wall surface with cement.
❸❹❺Side installation diagram.
How to calculate how many exhaust fans you need:
1.
Measure the length width and height of the construction site.
2.
Calculate the volume of the construction site.
3.
Measure the area of the window (if the exhaust fan is to be fixed on windows)
4.
Choose an exhaust fan model which size can fit on the window or on the wall.
5.
If there is no heat source on the construction site, then the ventilation rate is normally 30 times per hour.
If the construction site has heat source then we suggest the ventilation rate is up to 40-50 times per hour.
6.
Calculation formula: Numbers of exhaust fan = volume of the construction site (m³) X ventilation rate (normally 30) / air flow of the exhaust fan model(m³/h).
Product Case