Quick Details
-
Model Number:
-
CHP series online ups
-
Weight:
-
180Kg-2850Kg
-
Product name:
-
Online UPS
-
Display:
-
7 inch LCD+LED
-
Wave Form:
-
Pure Sine Wave output
-
Transfer time:
-
0ms
-
Efficiency:
-
95-99%
-
Battery Type:
-
Lead-acid Maintenance-free Battery / Gel
-
Battery Voltage:
-
384VDC
-
Certification:
-
CE,ISO,TLC
-
Appplication:
-
Telecommuications
Quick Details
-
Warranty:
-
1 year
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
BAYKEE or OEM
-
Model Number:
-
CHP series online ups
-
Weight:
-
180Kg-2850Kg
-
Product name:
-
Online UPS
-
Display:
-
7 inch LCD+LED
-
Wave Form:
-
Pure Sine Wave output
-
Transfer time:
-
0ms
-
Efficiency:
-
95-99%
-
Battery Type:
-
Lead-acid Maintenance-free Battery / Gel
-
Battery Voltage:
-
384VDC
-
Certification:
-
CE,ISO,TLC
-
Appplication:
-
Telecommuications
You may also like
Product Description
CHP3000 Series Low frequency Three Phase Online UPS 10kVA-600kVA
Brief introduction:
CHP3000 series online ups include the 10kVA to 600kVA (3 phase input & 3 phase output) double conversion On-Line UPS with an isolation transformer at output. The load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & output filters increase the immunity of load from power disturbances and surges.
This series UPS used high-speed microprocessor (MCU) and programmable logic device (CPLD) program which are controlled by software. It brings in the sixth generation low-exhaust and big-power IGBT and static switch as power components. Which enter into deduce digital ages of classic legend, bring up with the big capacity, high reliability, stability of function to reside global top-grade level. This series product combines the world’s newest control spare parts and the most advanced software.
CHP3000 series UPS entirely break through the technical bottleneck in traditional simulation age, it ingeniously adopt the digital control technology and high-precision SMD technology to assure ultra-high system stability and to fully acclimate various grid environment.
CHP3000 series online ups include the 10kVA to 600kVA (3 phase input & 3 phase output) double conversion On-Line UPS with an isolation transformer at output. The load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & output filters increase the immunity of load from power disturbances and surges.
This series UPS used high-speed microprocessor (MCU) and programmable logic device (CPLD) program which are controlled by software. It brings in the sixth generation low-exhaust and big-power IGBT and static switch as power components. Which enter into deduce digital ages of classic legend, bring up with the big capacity, high reliability, stability of function to reside global top-grade level. This series product combines the world’s newest control spare parts and the most advanced software.
CHP3000 series UPS entirely break through the technical bottleneck in traditional simulation age, it ingeniously adopt the digital control technology and high-precision SMD technology to assure ultra-high system stability and to fully acclimate various grid environment.
Single-machine capacity is ranging from 10KVA to 600KVA, which is widely used in telecom, bank ATM, bond agent, transporting,utility, manufacture, etc.
Main features:
◆Advanced digital circuit over stable operation
◆ Intelligent battery management, endurable and free from worry
◆ Intelligent surveillance system, full guardian
◆ Multiple redundancy
◆User-friendly touch backlight screen LCD display, flow chart running
◆Visual LED indicator: workflow indicator can be easily and clearly understood.
◆Excellent load characters
◆Thorough protection
◆High-performance dynamic characters
◆ 3 phases separately adjustment, balance stabilizing
◆Optional input harmonic filter or 12 pulse wave rectifier
◆Individualized settings
Specification
Model
|
CHP3010kVA
|
CHP3020kVA
|
CHP3030kVA
|
CHP3040kVA
|
CHP3060kVA
|
CHP3060kVA
|
CHP3080kVA
|
CHP3100kVA
|
CHP3120kVA
|
|||||||||
Nominal capacity (kVA)
|
10
|
20
|
30
|
40
|
50
|
60
|
80
|
100
|
120
|
|||||||||
Power (kW)
|
8
|
16
|
24
|
32
|
40
|
48
|
64
|
80
|
96
|
|||||||||
Work mode
|
Low frequency double conversion true online
|
|
|
|
|
|
|
|
|
|||||||||
Phase
|
Three phase 3L+N+G
|
|
|
|
|
|
|
|
|
|||||||||
Rectifier ( input )
|
|
|
|
|
|
|
|
|
|
|||||||||
Nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
|
|
|
|||||||||
Range
|
±25%
|
|
|
|
|
|
|
|
|
|||||||||
Frequency
|
50Hz±10% or 60Hz±10%
|
|
|
|
|
|
|
|
|
|||||||||
Output Ripple wave
|
<2%
|
|
|
|
|
|
|
|
|
|||||||||
Soft start
|
0~100% 5S
|
|
|
|
|
|
|
|
|
|||||||||
Charge
|
|
|
|
|
|
|
|
|
|
|||||||||
Charge mode
|
Constant current, then constant voltage, automatic switch between equalized charge and float charge, programmable timing battery charge-discharge automatic maintenance
|
|
|
|
|
|
|
|
|
|||||||||
Float charging voltage
|
435VDC
|
|
|
|
|
|
|
|
|
|||||||||
Charge current
|
0.1C ( Automatic adjust according to battery capacity), Example: 100Ah battery, the charge current is setted 10A, or according the charge time customer need
|
|
|
|
|
|
|
|
|
|||||||||
Battery
|
|
|
|
|
|
|
|
|
|
|||||||||
Type
|
Maintenance free lead-acid battery, optional lithium battery
|
|
|
|
|
|
|
|
|
|||||||||
Capacity
|
7~999AH settable (capacity vary with power)
|
|
|
|
|
|
|
|
|
|||||||||
Number
|
384VDC(12v 32pcs or 2v 192pcs), optional 360VDC (12v 30pcs, or 2v 180pcs)
|
|
|
|
|
|
|
|
|
|||||||||
Inverter
|
|
|
|
|
|
|
|
|
|
|||||||||
Phase
|
Three phase +N
|
|
|
|
|
|
|
|
|
|||||||||
Output power factor
|
0.8
|
|
|
|
|
|
|
|
|
|||||||||
Nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
|
|
|
|||||||||
Output voltage stability
|
±1%(steady load), ±5%(fluctuation of load)
|
|
|
|
|
|
|
|
|
|||||||||
Frequency stability
|
50Hz, 60Hz<±0. 5% ( Asynchronous )
|
|
|
|
|
|
|
|
|
|||||||||
Crest factor
|
3:1
|
|
|
|
|
|
|
|
|
|||||||||
Output waveform distortion degree
|
Pure sine wave, linear load<3%, non-linear load<5%
|
|
|
|
|
|
|
|
|
|||||||||
Dynamic feature
|
Transient voltage<±5% ( jump from 0% to 100% ), instant recovery time<10ms
|
|
|
|
|
|
|
|
|
|||||||||
Unbalance load voltage
|
<±5%
|
|
|
|
|
|
|
|
|
|||||||||
Overload protection
|
115% normal work, 125% 1 min, 150%1s
|
|
|
|
|
|
|
|
|
|||||||||
Efficiency
|
92% ( Full load )
|
|
|
|
|
|
93% ( Full load )
|
|
|
|||||||||
Bypass
|
|
|
|
|
|
|
|
|
|
|||||||||
Phase
|
3Phase+N
|
|
|
|
|
|
|
|
|
|||||||||
Input nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
|
|
|
|||||||||
Output nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
|
|
|
|||||||||
Transfer time
|
0ms (Static switch 0ms switch)
|
|
|
|
|
|
|
|
|
|||||||||
Protection function
|
|
|
|
|
|
|
|
|
|
|||||||||
Input protection
|
Voltage, frequency ultra limit, phase wrong, phase lost
|
|
|
|
|
|
|
|
|
|||||||||
Output protection
|
Over current, short circuit, over voltage, under voltage
|
|
|
|
|
|
|
|
|
|||||||||
Battery protection
|
Overcharge, over discharge protection
|
|
|
|
|
|
|
|
|
|||||||||
Temperature protection
|
Environment over-temperature protection, Inverter over-temperature protection
|
|
|
|
|
|
|
|
|
|||||||||
Hardware fault protection
|
Auxiliary power supply abnormal, breaker trip, fuse break, power device over current or overvoltage
|
|
|
|
|
|
|
|
|
|||||||||
Systems parameters
|
|
|
|
|
|
|
|
|
|
|||||||||
ECO mode
|
Can set the ECO mode, high efficiency up to 98%
|
|
|
|
|
|
|
|
|
|||||||||
Voice alarm
|
Any failure will be alerted
|
|
|
|
|
|
|
|
|
|||||||||
Work environment
|
Ambient temperature: 0~40℃, relative humidity: 30%~90%, altitude: <1000M ( power reduce 1% every 100M raised, 4000M utmost)
|
|
|
|
|
|
|
|
|
|||||||||
Cooling method
|
Forced ventilation
|
|
|
|
|
|
|
|
|
|||||||||
Communication port
|
RS232, RS485, Dry contact interface, Optional SNMP card for remote control
|
|
|
|
|
|
|
|
|
|||||||||
Redundancy function
|
Series connection hot backup or parallel, parallel current deviation≦5%
|
|
|
|
|
|
|
|
|
|||||||||
Anti surge capacity
|
10/700μS, 5KA, 8/20μS, 20KA
|
|
|
|
|
|
|
|
|
|||||||||
Protection level
|
IP21
|
|
|
|
|
|
|
|
|
|||||||||
Safety performance
|
I/O on ground resistance (2000VAC), stray current less than 10mA, insulation resistance exceeding 2MΩ(500VDC)
|
|
|
|
|
|
|
|
|
|||||||||
Noise(dB)
|
48~55
|
|
|
55~60
|
|
|
60~65
|
|
|
|||||||||
Mechanical size (W×D×H)mm
|
600×620×1250
|
|
|
700×600×1520
|
|
|
980×800×1800
|
|
|
|||||||||
Net weight(Kg)
|
205
|
265
|
311
|
407
|
485
|
506
|
770
|
913
|
937
|
Model
|
CHP3160kVA
|
CHP3200kVA
|
CHP3250kVA
|
CHP3300kVA
|
CHP400kVA
|
CHP3600kVA
|
||||||
Nominal capacity (kVA)
|
160
|
200
|
250
|
300
|
400
|
600
|
||||||
Power (kW)
|
128
|
160
|
200
|
240
|
320
|
480
|
||||||
Work mode
|
Low frequency double conversion true online
|
|
|
|
|
|
||||||
Phase
|
Three phase 3L+N+G
|
|
|
|
|
|
||||||
Rectifier ( input )
|
|
|
|
|
|
|
||||||
Nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
||||||
Range
|
±25%
|
|
|
|
|
|
||||||
Frequency
|
50Hz±10% or 60Hz±10%
|
|
|
|
|
|
||||||
Output Ripple wave
|
<2%
|
|
|
|
|
|
||||||
Soft start
|
0~100% 5S
|
|
|
|
|
|
||||||
Charge
|
|
|
|
|
|
|
||||||
Charge mode
|
Constant current, then constant voltage, automatic switch between equalized charge and float charge, programmable timing battery charge-discharge automatic maintenance
|
|
|
|
|
|
||||||
Float charging voltage
|
435VDC
|
|
|
|
|
|
||||||
Charge current
|
0.1C ( Automatic adjust according to battery capacity), Example: 100Ah battery, the charge current is setted 10A, or according the charge time customer need
|
|
|
|
|
|
||||||
Battery
|
|
|
|
|
|
|
||||||
Type
|
Maintenance free lead-acid battery, optional lithium battery
|
|
|
|
|
|
||||||
Capacity
|
7~999AH settable (capacity vary with power)
|
|
|
|
|
|
||||||
Number
|
384VDC(12v 32pcs or 2v 192pcs), optional 360VDC (12v 30pcs, or 2v 180pcs)
|
|
|
|
480VDC
|
|
||||||
Inverter
|
|
|
|
|
|
|
||||||
Phase
|
Three phase +N
|
|
|
|
|
|
||||||
Output power factor
|
0.8
|
|
|
|
|
|
||||||
Nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
||||||
Output voltage stability
|
±1%(steady load), ±5%(fluctuation of load)
|
|
|
|
|
|
||||||
Frequency stability
|
50Hz, 60Hz<±0. 5% ( Asynchronous )
|
|
|
|
|
|
||||||
Crest factor
|
3:1
|
|
|
|
|
|
||||||
Output waveform distortion degree
|
Pure sine wave, linear load<3%, non-linear load<5%
|
|
|
|
|
|
||||||
Dynamic feature
|
Transient voltage<±5% ( jump from 0% to 100% ), instant recovery time<10ms
|
|
|
|
|
|
||||||
Unbalance load voltage
|
<±5%
|
|
|
|
|
|
||||||
Overload protection
|
115% normal work, 125% 1 min, 150%1s
|
|
|
|
|
|
||||||
Efficiency
|
95% ( Full load )
|
|
|
|
|
|
||||||
Bypass
|
|
|
|
|
|
|
||||||
Phase
|
3Phase+N
|
|
|
|
|
|
||||||
Input nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
||||||
Output nominal voltage
|
380vac/400vac/420vac or customized 200vac/208vac/220vac/480vac
|
|
|
|
|
|
||||||
Transfer time
|
0ms (Static switch 0ms switch)
|
|
|
|
|
|
||||||
Protection function
|
|
|
|
|
|
|
||||||
Input protection
|
Voltage, frequency ultra limit, phase wrong, phase lost
|
|
|
|
|
|
||||||
Output protection
|
Over current, short circuit, over voltage, under voltage
|
|
|
|
|
|
||||||
Battery protection
|
Overcharge, over discharge protection
|
|
|
|
|
|
||||||
Temperature protection
|
Environment over-temperature protection, Inverter over-temperature protection
|
|
|
|
|
|
||||||
Hardware fault protection
|
Auxiliary power supply abnormal, breaker trip, fuse break, power device over current or overvoltage
|
|
|
|
|
|
||||||
Systems parameters
|
|
|
|
|
|
|
||||||
ECO mode
|
Can set the ECO mode, high efficiency up to 98%
|
|
|
|
|
|
||||||
Voice alarm
|
Any failure will be alerted
|
|
|
|
|
|
||||||
Work environment
|
Ambient temperature: 0~40℃, relative humidity: 30%~90%, altitude: <1000M ( power reduce 1% every 100M raised, 4000M utmost)
|
|
|
|
|
|
||||||
Cooling method
|
Forced ventilation
|
|
|
|
|
|
||||||
Communication port
|
RS232, RS485, Dry contact interface, Optional SNMP card for remote control
|
|
|
|
|
|
||||||
Redundancy function
|
Series connection hot backup or parallel, parallel current deviation≦5%
|
|
|
|
|
|
||||||
Anti surge capacity
|
10/700μS, 5KA, 8/20μS, 20KA
|
|
|
|
|
|
||||||
Protection level
|
IP21
|
|
|
|
|
|
||||||
Safety performance
|
I/O on ground resistance (2000VAC), stray current less than 10mA, insulation resistance exceeding 2MΩ(500VDC)
|
|
|
|
|
|
||||||
Noise(dB)
|
65~70
|
|
|
|
|
|
||||||
Mechanical size (W×D×H)mm
|
1380×950×1800
|
|
|
|
2265*855*1900
|
2865*955*1900
|
||||||
Net weight(Kg)
|
1350
|
1730
|
1800
|
1880
|
2500
|
3130
|
Packing & Delivery