Products
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter
SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter

SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter

FOB Reference Price: Get Latest Price
≥1 Sets
US $70
≥10 Sets
US $68
≥100 Sets
US $63
≥200 Sets
US $60
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
SY5000-1R5G-4
Output Frequency:
0~3000Hz
Size:
90MM*152MM*132.5MM
Weight:
1.4KG
Name:
AC Motor Drive 380V 5.5kW-280kW Frequency inverter
communication:
RS485 modbus, profibus
Allowed voltage range:
320V~460V
Input voltage:
3 phase 380V, 1 phase 220V
Output range:
3phase 0-460V, 1phase 0-260V
Over capacity G type:
110% for long term, 150% for 1 min
Cooling Method:
Air cooling with fan control
Analog input:
2 channel 0-10V and 0-20mA
Control mode:
5 control modes for choosing
Over capacity P type:
105% for long term, 120% for 1 min, 150% for 1 s

Quick Details

Output Current:
3.7A
Place of Origin:
Shanghai, China
Brand Name:
SANYU
Model Number:
SY5000-1R5G-4
Output Frequency:
0~3000Hz
Size:
90MM*152MM*132.5MM
Weight:
1.4KG
Name:
AC Motor Drive 380V 5.5kW-280kW Frequency inverter
communication:
RS485 modbus, profibus
Allowed voltage range:
320V~460V
Input voltage:
3 phase 380V, 1 phase 220V
Output range:
3phase 0-460V, 1phase 0-260V
Over capacity G type:
110% for long term, 150% for 1 min
Cooling Method:
Air cooling with fan control
Analog input:
2 channel 0-10V and 0-20mA
Control mode:
5 control modes for choosing
Over capacity P type:
105% for long term, 120% for 1 min, 150% for 1 s

SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter

SY5000 Description

SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter , excellent performance ,strong powerful ,stable quality ,sophisticated technology,The design fully consider the user demand , wide application scope .

Product Top Features
Input/Output voltage characteristic
Output frequency range: Low frequency:0~300Hz; High frequency: 0-1000Hz
Input voltage range:AC220V±15% ,AC380V±15%


Functional Characteristic
2 channels Analog input AI1:0~10V or 4~20mA with flexibly setting

2 channels Analog output 0~10V or 4~20mA choice.

General control
Speed control precision ±002Max Speed
Open-loop vector: 0.05hz can output 180% rated torque
V/F1:100 , Open-loop vector1:200
Technical Feature
Instantaneous power failure does not stop function
Rotating motor to realize no impact smooth starting
The function of user save parameters group and keyboard copy
16 segment programmable multi-velocity control

Built in PID controller, S type and Linear tye mode for choice of ACC. and DEC.

SY5000 new series Variable Speed Drive VFD/VSD/AC Motor Drive 380V 5.5kW-280kW Frequency inverter detailed parameters
Input Rated Voltage, Frequency 3-phase(4T#sereis)380V;50/60HZ
1-phase(2S#series)220V;50/60HZ
Allowed Voltage Range 3-phase(4T#series)320V~460V
1-phase(2S#series)160V~260V
Output Voltage 4T#series; 0~460V
2S#series; 0~260V
frequency Low frequency mode: 0~300HZ ; High frequency mode: 0~3000HZ
Overload Capacity G type: 110% for long-term, 150% for 1 min, 180% for 5s
P type: 105% for long-term, 120% for 1 min, 150% for 1s
Control Mode V/F control, advanced V/F control, V/F separation control, electric current vector control
Control Character Frequency Setting Resolution Analog Input 0.1% of maximum output frequency
Digital Setting 0.01 Hz
Frequency Precision Analog Input Within 0.2% of maximum output frequency
Digital Setting Within 0.01% of set output frequency
V/F Control V/F Curve (voltage frequency character) Reference frequency setting 5~600 Hz, multipoint V/F curve setting, or fixed curve of constant torque, low decreasing torque 1, low decreasing torque 2, square torque
Torque Compensation Manual setting: 0.0~30% of rated output
Automatic compensation: according to output current and motor parameter
Automatic Current-limiting and Voltage-limiting During acceleration, deceleration or steady running, detect automatically the current and voltage of motor stator, and control it within bounds based on unique algorithm, minimize fault-trip chance
Senseless Vector Control Voltage Frequency Character Adjust pressure/frequency ratio according to motor parameter and unique algorithm
Torque Character Starting torque:
3.0 Hz 150% rated torque (VF control)
0.5 Hz 180% rated torque (SVC, FVC)
0.05 Hz 180% rated torque (VC)
Operating speed precision in steady state: ≤±0.5% rated synchronous speed
Torque response: ≤50ms VC, SVC, FVC ≤20ms
Motor Parameter Self-measurement Being able to detect parameter automatically under static state and dynamic state of motor, thus guarantee an optimum control.
Current and Voltage Restrain Current closed-loop control, free from current impact, perfect restrain function of overcurrent and overvoltage
Undervoltage Restrain during Running Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation strategy
Typical function Multi-velocity and Traverse Operation 16 segments programmable multi-velocity control, multiple operation mode. Traverse operation: preset frequency and center frequency adjustable, parameter memory and recovery after power cut.
PID Control RS485 Communication Built-in PID controller (able to preset frequency). Standard configuration RS485 communication function, multiple communication protocol for choice, synchronizing control function.
Frequency Setting Analog Input Direct voltage 0~10V, direct current 0~20mA (optional up limit and lower limit)
Digital Input Operation panel setting, RS485 port setting, UP/DW terminal control, or combined with analog input
Output Signal Digital Input 2 channel OC output and one channel relay output (TA, TB, TC), up to 16 choices
Analog Input 2 channel analog signal output, output ranging within 0~20mA or 0~10V with flexibly setting, achievable output of physical quantities like set frequency, output frequency
Automatic Steady-voltage Operation Dynamic steady state, static steady state, and unsteady voltage for choices to obtain the steadiest operation
Acceleration and Deceleration Time Setting 0.1s~3600min continuous setting, S type and linear type mode for choice
Brake Dynamic Braking Dynamic braking initial voltage, backlash voltage and dynamic braking continuous adjustable
DC Braking Halt DC braking initial frequency: 0.00~[F0.16] upper limit frequency
Braking time: 0.0~100.0s;
Braking current: 0.0%~150.0% of rated current
Flux Restraint 0~100  0: invalid
Low Noise Running Carrier frequency 1.0kHz~16.0kHz continuous adjustable, minimize motor noise
Speed Tracking and Restart Function Smooth restart during operation, instantaneous stop and restart
Counter A built-in counter, facilitate system integration
Operation Function Upper limit and lower limit frequency setting, frequency hopping operation, reversal running restraint, slip frequency compensation, RS485 communication, frequency control of progressive increase and decrease, failure recovery automatically, etc.
Display Operation Panel Display Running  State Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback, analog input and output.
Alarm The latest 6 faults record; running parameters record when the latest fault tripping happens including output frequency, set frequency, output current, output voltage, DC voltage4 and module temperature.
Protective Function Overcurrent, overvoltage, undervoltage, module fault, electric thermal relay, overheat, short circuit, default phase of input and output, motor parameter adjustment abnormality, internal memory fault, etc.
Environment Ambient Temperature -10℃~+40℃ (please run the VFD in derated capacity when ambient temperature is 40℃~50℃)
Ambient Humidity 5%~95%RH, without condensing drops
Surroundings Indoors (without direct sunlight, corrosive or flammable gas, oil fog and dust)

Packaging & Shipping

Certificates we have

APP
Post My RFQ
WhatsApp
+86-17326049340