Automatic transfer switch mainly used for distribution or electromotor network, which under voltage 380V, rated voltage DC220V,Rated current 16A-3200A.
Main power and standby power or mutual standby power change over system or city power and generator group overload switch-over.Atthe same time, it can operated under un-frequency on and off circuit act as disconnector.
Widely used at the field of important power supply site, which transport, distribution power supply system and automatization system. For fire protection,hospital,bank,building,etc, where doesn't allow power off.
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
Mebay
-
Model Number:
-
ATS 250A
-
Rated Current:
-
250A
-
Frame current:
-
9999
-
Item Name:
-
Automatic Transfer Switch ATS 250A AC 400V Generator Transfer Switch
-
weight::
-
10kg
-
Max. Voltage:
-
380v
-
Pole:
-
3P and 4P
-
Certificate::
-
CE ISO9001
-
Max current:
-
16A~3200A
-
Operation type:
-
Auto&Manual, or Manual
-
Application:
-
Automatic Transfer Switch
-
Whether the smart:
-
Yes
Quick Details
-
Type:
-
PC
-
Number of Pole:
-
4
-
Place of Origin:
-
China
-
Brand Name:
-
Mebay
-
Model Number:
-
ATS 250A
-
Rated Current:
-
250A
-
Frame current:
-
9999
-
Item Name:
-
Automatic Transfer Switch ATS 250A AC 400V Generator Transfer Switch
-
weight::
-
10kg
-
Max. Voltage:
-
380v
-
Pole:
-
3P and 4P
-
Certificate::
-
CE ISO9001
-
Max current:
-
16A~3200A
-
Operation type:
-
Auto&Manual, or Manual
-
Application:
-
Automatic Transfer Switch
-
Whether the smart:
-
Yes
![](https://cdn.bestsuppliers.com/seo_products_img/mebay/5616ba08cefc363fb89899f26ded0583.jpg!/rotate/180)
Main Products
Products Description
Introduction
Transfer Switch for Generator Automatic Transfer Switch 4P ATS 250A
Frame Class
|
|
1600
|
|
250
|
630
|
1600
|
|
3200
|
|||||||
Agreed heating current Ith(A)
|
|
63
|
100
|
160-3200
|
|
|
|
|
|||||||
Rated current In(A)
|
|
16/20/25/32/40/50/63
|
80/ 100
|
125/160/250
|
400/630
|
800/1000/1250/1600
|
|
2000/2500/3200
|
|||||||
Rated insulation voltage(Ui)
|
|
690V
|
|
|
|
800V
|
|
|
|||||||
Rated short-circuit connection capacity
|
|
8KA
|
|
17KA
|
26KA
|
67KA
|
|
|
|||||||
Rated short-time withstand current(Icw)
|
|
5kA/30ms
|
|
10kA/60ms
|
12.6kA/60ms
|
32kA/60ms
|
|
|
|||||||
Transfer time I-II or II-I
|
|
2.5s
|
|
0.6s
|
|
1.2s
(Rated current In 800-1250)
|
1.8s
(Rated current In 1600-2500)
|
2.4s
(Rated current In 3200)
|
|||||||
Control voltage
|
|
DC24V、48V、110V,AC220V
|
|
|
|
|
|
|
|||||||
Rated frequency
|
Start
|
20W
|
|
325W
|
355W
|
400W
(Rated current In 800)
|
440W
(Rated current In1000-1600)
|
600W
(Rated current In 2000-3200)
|
|||||||
|
Normal
|
|
|
62W
|
74W
|
90W
(Rated current In 800)
|
98W
(Rated current In1000-1600)
|
120W
(Rated current In 2000-3200)
|
|||||||
Weight(kg) 4Pole
|
|
3.4
|
|
6.0/7.6
|
15.8/16.8
|
36
|
36/37/38.6
|
55/61/67
|
Recommend Products