- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
HBQ-065
-
Max Pulling Power:
-
2000N
-
Testing precision:
-
2%
-
Display precision:
-
0.1N
-
Max Stroke:
-
70mm
-
Power Supply:
-
220V/50Hz
-
Power:
-
Electronic
-
Place of origin:
-
Henan, China (Mainland)
-
Control method:
-
Microcomputer Control
-
Model:
-
HBQ-065
-
Usage:
-
Process Testing Machine
Quick Details
-
Use:
-
Testing
-
Place of Origin:
-
Henan, China
-
Brand Name:
-
HACINT
-
Model Number:
-
HBQ-065
-
Max Pulling Power:
-
2000N
-
Testing precision:
-
2%
-
Display precision:
-
0.1N
-
Max Stroke:
-
70mm
-
Power Supply:
-
220V/50Hz
-
Power:
-
Electronic
-
Place of origin:
-
Henan, China (Mainland)
-
Control method:
-
Microcomputer Control
-
Model:
-
HBQ-065
-
Usage:
-
Process Testing Machine
Details Images
Title goes here.
Auto-reset:
Be able to set the ooncltioos a the auto-reset and reset automaticaly after pul.-g the terrrinal off.
System setting: It is convenient to set the parameters, such as the up ard down lmts, caibralion and the condition a puling out.
System setting: It is convenient to set the parameters, such as the up ard down lmts, caibralion and the condition a puling out.
Title goes here.
Unit switch:
Quick switch between Kg ard N ard and any of them can be set as the default
Communication connection: Sending commands through the serial port can control the tester and return the peak force data. Text data can also be retuned via USB data interaction or imported into the MES system.
Communication connection: Sending commands through the serial port can control the tester and return the peak force data. Text data can also be retuned via USB data interaction or imported into the MES system.
Title goes here.
Data display:
Display the real-time and peak force simultaneously.
Data processing: The test data can be recorded, transmitted, elimilated, which make the data processing easy.
Data processing: The test data can be recorded, transmitted, elimilated, which make the data processing easy.
Force limits:
Alert when the pul force exceeds the limits.
Alert when the pul force exceeds the limits.
Product Paramenters
Model
|
HBQ-065
|
Power Supply
|
AC220/AC110 (Optional)
|
Rated Power
|
40W(Max)
|
Data acquisition speed
|
1KHz
|
Weight
|
18kq
|
Measuring range
|
5-2000N /0.5-200kg
|
Applied force accuracy
|
±2%
|
Dimensions
|
L380xW220x H210
|
Hot Searches