- Product Details
- {{item.text}}
Quick Details
-
BCD Curve:
-
C
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
CGZ
-
Model Number:
-
FG65L-63
-
Rated Frequency (Hz):
-
50/60Hz
-
Number of Pole:
-
4
-
Product name:
-
4P 20 amp iec 60934 two-pole GFCI Residual Current Circuit Breaker
-
Cover:
-
flame retardant
-
Certifications:
-
CE CB ISO9001
-
Internatonal standard:
-
GB10963.1 & IEC 60898.1
-
IP grade:
-
IP20
-
Supply capacity:
-
Examine the specific plant
-
Mechanical life:
-
20000 times
-
Poles Number:
-
4
Quick Details
-
Breaking Capacity:
-
4KA/6KA
-
Rated Voltage:
-
380V, 380V
-
Rated Current:
-
16,25,32, 40,63A
-
BCD Curve:
-
C
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
CGZ
-
Model Number:
-
FG65L-63
-
Rated Frequency (Hz):
-
50/60Hz
-
Number of Pole:
-
4
-
Product name:
-
4P 20 amp iec 60934 two-pole GFCI Residual Current Circuit Breaker
-
Cover:
-
flame retardant
-
Certifications:
-
CE CB ISO9001
-
Internatonal standard:
-
GB10963.1 & IEC 60898.1
-
IP grade:
-
IP20
-
Supply capacity:
-
Examine the specific plant
-
Mechanical life:
-
20000 times
-
Poles Number:
-
4
Recommend Products
Product Description
Specification
1. The FG65L-63 series are mainly used in varieties of factories; enterprises and building construction.
2. 2 phase 230V and 4 phase 400V 50/60Hz, rated current 16, 20, 25, 40, 50, 63(A).
3. They are not suitable for use in DC pulse system.
4.They can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk
5. It is suitable to avoid the shock hazard and fire caused by earth leakage.
6. They are in conformity with the standard of IEC61008.
2. 2 phase 230V and 4 phase 400V 50/60Hz, rated current 16, 20, 25, 40, 50, 63(A).
3. They are not suitable for use in DC pulse system.
4.They can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk
5. It is suitable to avoid the shock hazard and fire caused by earth leakage.
6. They are in conformity with the standard of IEC61008.
Number of poles
|
|
2P 4P
|
|
||
Breaking capacity
|
|
6KA
|
|
||
Rated current(A)
|
|
16/25/40/63A
|
|
||
Rated voltage(V)
|
|
AV 2P 230/240V 4P400/415V
|
|
||
Rated residual operating current(mA)
|
|
30,100,3000,500ma
|
|
||
Rated residual non-operation current(In)
|
|
0.5In
|
|
||
Residual operating current scope
|
|
0.5In~In
|
|
||
Residual current breaking time
|
|
≤0.3s
|
|
||
Residual current trip characteristics
|
|
A,AC
|
|
||
Ultimate short-circuit breaking capacity
|
|
6000A
|
|
||
Endurance
|
|
≥4000
|
|
||
Connection Capacity
|
|
≤25mm²
|
|
||
Degree of protection
|
|
IP20
|
|
||
Standard
|
|
GB10963.1 & IEC 60898.1
|
|