Quick Details
-
Voltage:
-
220/50Hz
-
Dimension(L*W*H):
-
500*680*1350mm
-
Weight:
-
100 KG
-
Power:
-
4kw
-
Working Temperature Range:
-
-25 to 30 ℃
-
Cooling type:
-
Low Temperature Coolant Circulation Pump
-
Condenser:
-
famous brand
-
Refrigerant:
-
R404A
-
Product name:
-
Low temperature circulator chiller
-
Cooling capacity:
-
1.5-4kw
-
Storage tank volume:
-
25L
-
Evaporator:
-
Plate heat exchanger
-
Shell material:
-
Cold rolled plate spray, SUS304
-
Marketing Type:
-
Ordinary Product
Quick Details
-
Condition:
-
New
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
CAREDDI
-
Voltage:
-
220/50Hz
-
Dimension(L*W*H):
-
500*680*1350mm
-
Weight:
-
100 KG
-
Power:
-
4kw
-
Working Temperature Range:
-
-25 to 30 ℃
-
Cooling type:
-
Low Temperature Coolant Circulation Pump
-
Condenser:
-
famous brand
-
Refrigerant:
-
R404A
-
Product name:
-
Low temperature circulator chiller
-
Cooling capacity:
-
1.5-4kw
-
Storage tank volume:
-
25L
-
Evaporator:
-
Plate heat exchanger
-
Shell material:
-
Cold rolled plate spray, SUS304
-
Marketing Type:
-
Ordinary Product
Product Description
Low temperature circulator chiller
Low temperature circulator, called chiller, mainly used in heavy chemical industry, energy, food, pharmaceutical, bioengineering, metallurgy and other industrial production processes that work under low temperature conditions.
Product Features
1. Circulating refrigeration medium: synthetic heat transfer oil, industrial alcohol or water-ethylene glycol mixture for
circulating refrigeration, saving resources.
2. Strict circulating pipeline design prevents circulating sewage and prolongs the use time of circulating water.
3. Multiple safety protection, reliable operation.
4. Original imported compressor, cascade subcooling refrigeration technology.
5. Adopt supercooling technology to ensure temperature stability at low temperature.
6. The temperature difference between the compressor on and off can be set.
7. Ambient temperature detection function to prevent the system from running too high.
8. Over temperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm, etc.
9. Adopt closed design, no water absorption in low temperature process, to ensure the purity of cold and heat transfer medium.
10. High-performance circulating pump can guarantee continuous operation 24 hours a day.
11. Plate heat exchanger is adopted to improve heat exchange efficiency.
12. Prevents ice crystals and provides thermal fluid life.
circulating refrigeration, saving resources.
2. Strict circulating pipeline design prevents circulating sewage and prolongs the use time of circulating water.
3. Multiple safety protection, reliable operation.
4. Original imported compressor, cascade subcooling refrigeration technology.
5. Adopt supercooling technology to ensure temperature stability at low temperature.
6. The temperature difference between the compressor on and off can be set.
7. Ambient temperature detection function to prevent the system from running too high.
8. Over temperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm, etc.
9. Adopt closed design, no water absorption in low temperature process, to ensure the purity of cold and heat transfer medium.
10. High-performance circulating pump can guarantee continuous operation 24 hours a day.
11. Plate heat exchanger is adopted to improve heat exchange efficiency.
12. Prevents ice crystals and provides thermal fluid life.
Specification
Model
|
|
DL-0250
|
DL-0400
|
DL-0700
|
DL-1000
|
DL-1450
|
DL-2000
|
DL-2600
|
|||||||
Temp range
|
|
-25℃-30℃
|
|
|
|
|
|
|
|||||||
Temperature control & display
|
|
ASET multi-function controller, touch screen operation and display, optional color
|
|
|
|
|
|
|
|||||||
Temperature control selection
|
|
Control the temperature of refrigerant outlet
|
|
|
|
|
|
|
|||||||
Communication protocol
|
|
MODBUS TRU Protocol RS485 interface
|
|
|
|
|
|
|
|||||||
Temperature feedback
|
|
The built-in refrigerant medium PT100 feedback
|
|
|
|
|
|
|
|||||||
Refrigeration output
|
0℃
|
1.5kw
|
2.4kw
|
4kw
|
7.5kw
|
10kw
|
15kw
|
20kw
|
|||||||
|
-10℃
|
1kw
|
1.5kw
|
2.7kw
|
6.3kw
|
8kw
|
12kw
|
15kw
|
|||||||
|
-20℃
|
0.55kw
|
0.8kw
|
1.5kw
|
3.5kw
|
5kw
|
7.3kw
|
10kw
|
|||||||
Circulating Pump flow rate & Pressure
|
|
Max 20L/min
1.5bar |
Max 20L/min
1.5bar |
Max 35L/min
2.5bar |
Max 35L/min
2.5bar |
Max 75L/min
2.5bar |
Max 75L/min
2.5bar |
Max 110L/min
2.5bar |
|||||||
Tank
|
|
15L
|
15L
|
25L
|
25L
|
40L
|
60L
|
80L
|
|||||||
Compressor
|
|
TECUMSEH or Copeland
|
|
|
|
|
|
|
|||||||
Evaporator
|
|
Plate heat exchanger
|
|
|
|
|
|
|
|||||||
Operation panel
|
|
Touch button, LCD screen display
|
|
|
|
|
|
|
|||||||
Safety protection
|
|
Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermal protection device, and other safety protection functions.
|
|
|
|
|
|
|
|||||||
Refrigerant
|
|
R404A
|
|
|
|
|
|
|
|||||||
Power supply
|
|
220V/50Hz
1.5kw(max) |
220V/50Hz
2kw(Max) |
220V/50Hz
2.5kw(Max) |
380V/50Hz
3.5kw(Max) |
380V/50Hz
5kw(Max) |
380V/50Hz
6.5kw(Max) |
380V/50Hz
8.5kw(Max) |
|||||||
Refrigerant output interface
|
|
DN15
|
DN20
|
DN20
|
DN20
|
DN20
|
DN20
|
DN25
|
|||||||
Dimensions
|
|
400*600*1150mm
|
400*600*1150mm
|
500*680*1350mm
|
500*680*1350mm
|
650*700*1650mm
|
750*750*1800mm
|
850*850*1850mm
|
|||||||
Shell material
|
|
Cold rolled plate spray (Optional: SUS304)
|
|
|
|
|
|
|
Packing & Delivery
Hot Searches